999 resultados para validação analítica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of analytical methods was carried out for di-(ethylhexyl) phthalate (DEHP) and adipate (DEHA) the determination of in PVC films. The level of DEHP and DEHA in samples was determined by leaving the film in contact with n-heptane during 48 hours and analysis in a gas chromatograph (GC) equipped with a flame ionization detector and fused silica column with 5% phenylmethyl silicone in the dimensions 30 m x 0.53 mm x 2.65 mm. The results for detection and the quantification limits were smaller than the restriction limits. The recovery rates of DEHP and DEHA were, respectively, 69.10 and 75.30 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an alternate method to detect forbidden doping substances present in biological matrices of horseracing. The method was fully validated for caffeine, identified as the most frequent forbidden substance in the analysis conducted by the Antidoping Laboratory of the Brazilian Jockey Club, which adopts a zero threshold limit according to national and international horseracing practices. The metrological reliability of the method applied to toxicological analysis in biological matrices is discussed. Although the analytical method proposed for detection of a zero threshold level of the doping substance is qualitative, it was validated for the determination of the limiting value (also known as quantification limit value) introducing a criterion that prevents the issuing of incorrect results ("false-positives" and "false-negatives").

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate a method of analysis of biodiesel:diesel blends using HRGC-MS in SIM mode. The proposed method is applicable to biodiesel from linoleic oils, such as soybean oil. The following results were obtained: linearity over the methyl linoleate concentration range of 250-2500 mg L-1 (R² > 0.999); limits of detection and quantification of 2 and 5 mg L-1, respectively; recovery from 82 to 96% of biodiesel in diesel and repeatability < 2% (RSD). Comparison between two operators showed that it is not necessary the same operator to do the analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work is to develop an efficient procedure to determine glyphosate in soybean grains. The cleanup of the aqueous extracts was done in two steps, beginning with liquid-liquid partitioning and then solid-phase extraction with anion exchange resin. After derivatization with a mixture of trifluoroacetic anhydride (TFAA) and trifluoroethanol (TFE), quantification was done by gas chromatography coupled to mass spectrometry. The mean recovery and RSD of the spiked samples were, respectively, 80.5% and 3.1% at level 0.200 mg kg-1, 93.3% and 18.7% at level 0.500 mg kg-1 and 92% and 3.5% at level 1.000 mg kg-1. The method was linear in the working range (correlation coefficient = 0.9965).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the VALIDATION SPREADSHEET, a public domain tool that can be used to evaluate the figures of merit for univariate analytical methods. A real example of BTEX determination in environmental samples is included to illustrate its use. The spreadsheet has been developed for Excel® and Open Office®, and is available on the internet at http//lqta.iqm.unicamp.br.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considered the best substitute for diesel, biodiesel can be blended with diesel in any ratio, bringing lots of environmental, economic and social advantages. Brazilian law Nº 11097/2005, proposes the introduction of biodiesel in to the Brazilian energy matrix, mixed with diesel at a minimum percentage of 2%. For consumers and sellers to be sure that the commercialized mixture of biodiesel:diesel contains the correct percentage, it is necessary to develop analytical methodologies to quantify the amount of biodiesel added. This work presents a fast, low-cost and simple methodology to determine the biodiesel proportion in mixtures of biodiesel:diesel, based on infrared spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a translation of an IUPAC document by K. Danzer, M. Otto and L. A. Currie (Pure Appl. Chem., 2004, 76(6), 1215-1225). Its goal is to establish a uniform and meaningful standard for terminology (in Portuguese), notation, and formulation concerning multispecies calibration in analytical chemistry. Calibration in analytical chemistry refers to the relation between sample domain and measurement domain (signal domain) expressed by an analytical function x = f s (Q) representing a pattern of chemical species Q and their amounts or concentrations x in a given test sample and a measured function y = f (z) that may be a spectrum, chromatogram, etc. Simultaneous multispecies analyses are carried out mainly by spectroscopic and chromatographic methods in a more or less selective way. For the determination of n species Qi (i=1,2, ..., n), at least n signals must be measured which should be well separated in the ideal case. In analytical practice, the situation can be different.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complex B vitamins are present in some cereal foods and the ingestion of enriched products contributes to the recommended dietary intake of these micronutrients. To adapt the label of some products, it is necessary to develop and validate the analytical methods. These methods must be reliable and with enough sensitivity to analyze complex B vitamins naturally present in food at low concentration. The purpose of this work is to evaluate, with validated methods, the content of vitamins B1, B2, B6 and niacin in five cereal flours used in food industry (oat, rice, barley, corn and wheat).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the quantitation of lamivudine, zidovudine and nevirapine in the fixed-dose combination film-coated tablet by high performance liquid chromatography, in accordance with RE No. 899/2003, National Sanitary Surveillance Agency. It was based on an isocratic elution system with a potassium phosphate buffer pH 3.0: acetonitrile (60:40 v/v) mobile phase, C18, 250 x 46 mm column, 10µm particle size, λ 270 nm. The statistically evaluated results have shown that the method is specific, precise, accurate, and robust, ensuring the analytical safety of 3TC, AZT and NVP determination, which emerges as a new therapeutic alternative for antiretroviral treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different agencies that supply validation guidelines worldwide establish almost the same parameters to be evaluated in the validation process of bioanalytical methods. However, they recommend different procedures, as well as establish different acceptance criteria. The present review delineates and discusses the stages involved in the validation procedures of bioanalytical methods designed for determining veterinary residues in food, explaining the main differences in the guidelines established for this purpose by the main regulatory agencies in the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A chromatographic method was developed for cholesterol determination in feed for ruminants using response surface methodology. Among the five approaches of sample preparation methods tested, the saponification of the sample without heating presented less interference in the gas chromatography. The method presented a relative standard deviation (RSD) of 4.3%, recoveries between 84 and 87% and detection limit of 0.001 mg of cholesterol per g of feed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plastic packaging materials intended for use in food packaging is an area of great interest from the scientific and economic point of view due to the irreversible internationalization and globalization process of food products. Nevertheless, a debate related to food safety aspects has emerged within the scientific community. Therefore, the development of analytical methods that allow identifying and quantifying chemical substances of toxicological potential in the packaging is considered essential. This article focuses on the main analytical methods, including validation parameters, as well as extraction and quantification techniques for determination of volatile organic compounds from food packaging materials.