986 resultados para transport-measurements
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The human blood fluke Schistosoma mansoni is the primary cause of schistosomiasis, a debilitating disease that affects 200 million individuals in over 70 countries. The biogenic amine serotonin is essential for the survival of the parasite and serotonergic proteins are potential novel drug targets for treating schistosomiasis. Here we characterize two novel serotonin transporter gene transcripts, SmSERT-A and SmSERT-B, from S. mansoni. Southern blot analysis shows that the two mRNAs are the products of different alleles of a single SmSERT gene locus. The two SmSERT forms differ in three amino acid positions near the N-terminus of the protein. Both SmSERTs are expressed in the adult form and in the sporocyst form (infected snails) of the parasite, but are absent from all other stages of the parasite`s complex life cycle. Heterologous expression of the two cDNAs in mammalian cells resulted in saturable, sodium-dependent serotonin transport activity with an apparent affinity for serotonin comparable to that of the human serotonin transporter. Although the two SmSERTs are pharmacologically indistinguishable from each other, efflux experiments reveal notably higher substrate selectivity for serotonin compared with their mammalian counterparts. Several well-established substrates for human SERT including (+/-)MDMA, S-(+)amphetamine, RU 24969, and m-CPP are not transported by SmSERTs, underscoring the higher selectivity of the schistosomal isoforms. Voltage-clamp recordings of SmSERT substrate-elicited currents confirm the substrate selectivity observed in efflux experiments and suggest that it may be possible to exploit the electrogenic nature of SmSERT to screen for compounds that target the parasite in vivo. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Bone transport is based on the principle of distraction osteogenesis described by Ilizarov and is a consecrated method for the treatment of segmental bone defects. One of its most problematic and, paradoxically, least studied aspects is the consolidation of the docking site. We studied histologically the ossification of the docking site and regenerate to determine any difference between them. Nine adult sheep were submitted to correction of a 1-cm tibial diaphyseal defect using a system of plate-fixed bone transport, with latency period of 1 week and 0.2 mm distraction of the transported segment four times a day. The sheep were divided into three groups of three animals each, according to the observation period of 3, 6 or 12 weeks between the fixation of the transported fragment and the euthanasia. The docking site and the regenerate were studied histologically on sections stained with Masson trichrome. The main mode of docking site ossification was the endochondral one and although intramembranous ossification was also observed simultaneously, it was limited to rare and small foci. In contrast, intramembranous ossification played the major role in the regenerate, with bone formation evolving from the base segment to the target segment. The experimental bone transport model proposed in the present study permits us to conclude that there is a clear difference between the ossification of the docking site and of the regenerate.