995 resultados para total war


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Currently, many pre-conditions are regarded as relative or absolute contraindications for lumbar total disc replacement (TDR). Radiculopathy is one among them. In Switzerland it is left to the surgeon's discretion when to operate if he adheres to a list of pre-defined indications. Contraindications, however, are less clearly specified. We hypothesized that, the extent of pre-operative radiculopathy results in different benefits for patients treated with mono-segmental lumbar TDR. We used patient perceived leg pain and its correlation with physician recorded radiculopathy for creating the patient groups to be compared. METHODS: The present study is based on the dataset of SWISSspine, a government mandated health technology assessment registry. Between March 2005 and April 2009, 577 patients underwent either mono- or bi-segmental lumbar TDR, which was documented in a prospective observational multicenter mode. A total of 416 cases with a mono-segmental procedure were included in the study. The data collection consisted of pre-operative and follow-up data (physician based) and clinical outcomes (NASS form, EQ-5D). A receiver operating characteristic (ROC) analysis was conducted with patients' self-indicated leg pain and the surgeon-based diagnosis "radiculopathy", as marked on the case report forms. As a result, patients were divided into two groups according to the severity of leg pain. The two groups were compared with regard to the pre-operative patient characteristics and pre- and post-operative pain on Visual Analogue Scale (VAS) and quality of life using general linear modeling. RESULTS: The optimal ROC model revealed a leg pain threshold of 40 ≤ VAS > 40 for the absence or the presence of "radiculopathy". Demographics in the resulting two groups were well comparable. Applying this threshold, the mean pre-operative leg pain level was 16.5 points in group 1 and 68.1 points in group 2 (p < 0.001). Back pain levels differed less with 63.6 points in group 1 and 72.6 in group 2 (p < 0.001). Pre-operative quality of life showed considerable differences with an 0.44 EQ-5D score in group 1 and 0.29 in group 2 (p < 0.001, possible score range -0.6 to 1). At a mean follow-up time of 8 months, group 1 showed a mean leg pain improvement of 3.6 points and group 2 of 41.1 points (p < 0.001). Back pain relief was 35.6 and 39.1 points, respectively (p = 0.27). EQ-5D score improvement was 0.27 in group 1 and 0.41 in group 2 (p = 0.11). CONCLUSIONS: Patients labeled as having radiculopathy (group 2) do mostly have pre-operative leg pain levels ≥ 40. Applying this threshold, the patients with pre-operative leg pain do also have more severe back pain and a considerably lower quality of life. Their net benefit from the lumbar TDR is higher and they do have similar post-operative back and leg pain levels as well as the quality of life as patients without pre-operative leg pain. Although randomized controlled trials are required to confirm these findings, they put leg pain and radiculopathy into perspective as absolute contraindications for TDR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malignant melanoma, the deadliest form of skin cancer, is characterized by a predominant mutation in the BRAF gene. Drugs that target tumours carrying this mutation have recently entered the clinic. Accordingly, patients are routinely screened for mutations in this gene to determine whether they can benefit from this type of treatment. The current gold standard for mutation screening uses real-time polymerase chain reaction and sequencing methods. Here we show that an assay based on microcantilever arrays can detect the mutation nanomechanically without amplification in total RNA samples isolated from melanoma cells. The assay is based on a BRAF-specific oligonucleotide probe. We detected mutant BRAF at a concentration of 500 pM in a 50-fold excess of the wild-type sequence. The method was able to distinguish melanoma cells carrying the mutation from wild-type cells using as little as 20 ng µl(-1) of RNA material, without prior PCR amplification and use of labels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo consiste en la traducción del alemán al español de un fragmento del libro NS-Offizzier war ich nicht (Ute Althaus), en el cual se aborda el tópico del nacionalsocialismo desde el ámbito familiar y bajo una perspectiva psico-social.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Does economic growth affect the likelihood of civil war? Answering this question requires dealing with reverse causation. Our approach exploits that international commodity prices have a significant effect on the income growth of Sub-Saharan African countries. We show that lower income growth makes civil war more likely in non-democracies. This effect is significantly weaker in democracies; as a result, we find no link between growth and civil war in these countries. Our reducedform results also indicate that lower international commodity price growth has no effect on civil war in democracies, but raises the likelihood of civil war incidence and onset in nondemocracies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfully and the patient made an uneventfully recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is used increasingly to measure liver volume in patients undergoing evaluation for transplantation or resection. This study is designed to determine a formula predicting total liver volume (TLV) based on body surface area (BSA) or body weight in Western adults. TLV was measured in 292 patients from four Western centers. Liver volumes were calculated from helical computed tomographic scans obtained for conditions unrelated to the hepatobiliary system. BSA was calculated based on height and weight. Each center used a different established method of three-dimensional volume reconstruction. Using regression analysis, measurements were compared, and formulas correlating BSA or body weight to TLV were established. A linear regression formula to estimate TLV based on BSA was obtained: TLV = -794.41 + 1,267.28 x BSA (square meters; r(2) = 0.46; P &lt;.0001). A formula based on patient weight also was derived: TLV = 191.80 + 18.51 x weight (kilograms; r(2) = 0.49; P &lt;.0001). The newly derived TLV formula based on BSA was compared with previously reported formulas. The application of a formula obtained from healthy Japanese individuals underestimated TLV. Two formulas derived from autopsy data for Western populations were similar to the newly derived BSA formula, with a slight overestimation of TLV. In conclusion, hepatic three-dimensional volume reconstruction based on helical CT predicts TLV based on BSA or body weight. The new formulas derived from this correlation should contribute to the estimation of TLV before liver transplantation or major hepatic resection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How did Europe overtake China? We construct a simple Malthusian model with two sectors, and use it to explain how European per capita incomes and urbanization rates could surge ahead of Chinese ones. That living standards could exceed subsistence levels at all in a Malthusian setting should be surprising. Rising fertility and falling mortality ought to have reversed any gains. We show that productivity growth in Europe can only explain a small fraction of rising living standards. Population dynamics - changes of the birth and death schedules - were far more important drivers of the longrun Malthusian equilibrium. The Black Death raised wages substantially, creating important knock-on effects. Because of Engel's Law, demand for urban products increased, raising urban wages and attracting migrants from rural areas. European cities were unhealthy, especially compared to Far Eastern ones. Urbanization pushed up aggregate death rates. This effect was reinforced by more frequent wars (fed by city wealth) and disease spread by trade. Thus, higher wages themselves reduced population pressure. Without technological change, our model can account for the sharp rise in European urbanization as well as permanently higher per capita incomes. We complement our calibration exercise with a detailed analysis of intra-European growth in the early modern period. Using a panel of European states in the period 1300-1700, we show that war frequency can explain a good share of the divergent fortunes within Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Comparison of the Management Models of Protected Areas between China and the African South Region allows reading and evaluating the similarities and differences in the use of management model as a management tool for protected areas in China and South African Region. Specifically, some positive and negative features of the management approaches for the two regions. Secondary data was collected from various related literature such as policy documents, students‟ dissertations/thesis, scientific articles and magazines. Based on the method above, the study found out that China's first nature reserve was the Dingus Mountain Nature Reserve in Zhaoqing, Guangdong province established in 1956. By the end of 2005, about 2,349 nature reserves of various kinds were set up throughout the country, covering a total area of 149.95 million ha and accounting for 15 percent of the total land territory. The study further found that Southern Africa has approximately 4,390 protected areas out of 11487920 total land areas and Eastern Africa has approximately 1838144 protected areas, which is equivalent to 15.0% of the total land areas. South Africa in this region had its first declared natural park in 1926 after Paul Kruger (a war hero) had alerted the authorities of the extinguishing threat of some animal species of region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paralysis with pancuronium bromide is used in newborn infants to facilitate ventilatory support during respiratory failure. Changes in lung mechanics have been attributed to paralysis. The aim of this study was to examine whether or not paralysis per se has an influence on the passive respiratory mechanics, resistance (Rrs) and compliance (Crs) of the respiratory system in newborn infants. In 30 infants with acute respiratory failure, Rrs was measured during paralysis with pancuronium bromide and after stopping pancuronium bromide (group A). Rrs was also measured in an additional 10 ventilated infants in a reversed fashion (group B): Rrs was measured first in nonparalysed infants and then they were paralysed, mainly for diagnostic procedures, and the Rrs measurement repeated. As Rrs is highly dependent on lung volume, several parameters, that depend directly on lung volume were recorded: inspiratory oxygen fraction (FI,O2), arterial oxygen tension/alveolar oxygen tension (a/A) ratio and volume above functional residual capacity (FRC). In group A, the Rrs was not different during (0.236+/-0.09 cmH2O x s x mL(-1)) and after (0.237+/-0.07 cmH2O x s x mL(-1)) paralysis. Also, in group B, Rrs did not change (0.207+/-0.046 versus 0.221+/-0.046 cm x s x mL(-1) without versus with pancuronium bromide). FI,O2, a/A ratio and volume above FRC remained constant during paralysis. These data demonstrate that paralysis does not influence the resistance of the total respiratory system in ventilated term and preterm infants when measured at comparable lung volumes.