916 resultados para quantitative radioautography
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.
Resumo:
A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.
Resumo:
A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.
Resumo:
Genetic algorithm and multiple linear regression (GA-MLR), partial least square (GA-PLS), kernel PLS (GA-KPLS) and Levenberg-Marquardt artificial neural network (L-M ANN) techniques were used to investigate the correlation between retention index (RI) and descriptors for 116 diverse compounds in essential oils of six Stachys species. The correlation coefficient LGO-CV (Q²) between experimental and predicted RI for test set by GA-MLR, GA-PLS, GA-KPLS and L-M ANN was 0.886, 0.912, 0.937 and 0.964, respectively. This is the first research on the QSRR of the essential oil compounds against the RI using the GA-KPLS and L-M ANN.
Resumo:
This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.
Resumo:
The hydroalcoholic extracts prepared from standard leaves of Maytenus ilicifolia and commercial samples of espinheira-santa were evaluated qualitatively (fingerprinting) and quantitatively. In this paper, fingerprinting chromatogram coupled with Principal Component Analysis (PCA) is described for the metabolomic analysis of standard and commercial espinheira-santa samples. The epicatechin standard was used as an external standard for the development and validation of a quantitative method for the analysis in herbal medicines using a photo diode array detector. This method has been applied for quantification of epicatechin in commercialized herbal medicines sold as espinheira-santa in Brazil and in the standard sample of M. ilicifolia.
Resumo:
Prior to obtain a standardized dried extract from V. ferruginea, lupeol was first time isolated from leaves and used as chemical maker. An analytical method using HPLC-PDA for lupeol determination in V. ferruginea intermediate products was developed using a C8 reverse-phase column, acetonitrile-acetic acid (99.99:0.01, v/v) as mobile phase at 0.8 mL min-1, oven temperature at 23-25 ºC, sample injection volume at 30 µL and detection at 210 nm. The method presented linearity from 10 to 160 µg mL-1, accuracy, precision, robustness and suitable sensitivity proving to be a useful tool to the obtainment process of lupeol standardized dried extracts of V. ferruginea.
Resumo:
This work quantifies two important epidemiological features of the bean (Phaseolus vulgaris)/Phaeoisariopsis griseola pathosystem. The first is the effect of the number of nights of leaf wetness on infection efficiency. Infection efficiency was below 10% when inoculated leaflets were exposed to less than two nights of leaf wetness. Optimum infection efficiencies were obtained after three to four nights of leaf wetness, at about 50%. Further nights of leaf wetness did not increase the infection efficiency. The second feature quantified is the relative rate of leaflet defoliation for varying levels of angular leaf spot severity. It increased with disease severity according to a logarithm-like curve, and a relative rate of 0.23 day-1 was estimated for a severity of 18%. The implications of these results on the disease epidemiology are discussed.
Resumo:
Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of total sulfur in the form of sulfate, precipitated in the form of barium sulfate, is presented. The method was applied to biodiesel, to plant leaves and to natural waters analysis. The analytical signal (S) correlates linearly with sulfate concentration (C) between 20 and 120 ppm, through the equation S=-1.138+0.0934 C (r = 0.9993). The experimentally observed limit of detection is about 10 ppm. The mean R.S.D. is about 3.0 %. Real samples containing sulfate were analyzed and the results obtained by the FI and by the reference batch turbidimetric method using the statistical Student's t-test and F-test were compared.
Resumo:
A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.
Resumo:
Two Lettuce mosaic virus isolates capable of overcoming the resistance afforded by the resistance gene mo1² in lettuce, LMV-AF199 from Brazil, and LMV-E, an European isolate, were evaluated for the rapidity and severity of symptoms induced on the lettuce variety Salinas 88 (mo1²). The mosaic symptoms on Salinas 88 plants inoculated with LMV-AF199 appeared 7 days post-inoculation (dpi) and 15 dpi for LMV-E. The symptoms induced by LMV-AF199 in this cultivar were also more severe than those induced by LMV-E. In order to identify the region of the viral genome responsible for this phenotype, recombinant viruses were constructed between these isolates and the phenotype of each recombinant was analysed. The region encoding proteins P1 and HcPro from LMV-AF199 was associated with the increased virulence in Salinas 88.
Resumo:
This research focuses on the link between quantitative sustainability disclosure and information asymmetry. It builds upon previous research which links information asymmetry with voluntary disclosure. Stakeholders from the financial services sector claim that sustainability disclosure needs to be more numerical and comparable between companies. This research covers 111 firms from Denmark, Finland, the Netherlands and Sweden from non-service industries and studies how quantitative their sustainability disclosure is, and whether or not there is a negative relation with information asymmetry. The results support the hypotheses, where two out of three information asymmetry proxies have a significant negative relation with quantitative disclosure. Size is supported as a moderating factor. Quantitativity also proves to have a significant link with third party sustainability ratings. The direct link between quantitativity and cost of capital is not however supported.
Resumo:
Since its introduction, fuzzy set theory has become a useful tool in the mathematical modelling of problems in Operations Research and many other fields. The number of applications is growing continuously. In this thesis we investigate a special type of fuzzy set, namely fuzzy numbers. Fuzzy numbers (which will be considered in the thesis as possibility distributions) have been widely used in quantitative analysis in recent decades. In this work two measures of interactivity are defined for fuzzy numbers, the possibilistic correlation and correlation ratio. We focus on both the theoretical and practical applications of these new indices. The approach is based on the level-sets of the fuzzy numbers and on the concept of the joint distribution of marginal possibility distributions. The measures possess similar properties to the corresponding probabilistic correlation and correlation ratio. The connections to real life decision making problems are emphasized focusing on the financial applications. We extend the definitions of possibilistic mean value, variance, covariance and correlation to quasi fuzzy numbers and prove necessary and sufficient conditions for the finiteness of possibilistic mean value and variance. The connection between the concepts of probabilistic and possibilistic correlation is investigated using an exponential distribution. The use of fuzzy numbers in practical applications is demonstrated by the Fuzzy Pay-Off method. This model for real option valuation is based on findings from earlier real option valuation models. We illustrate the use of number of different types of fuzzy numbers and mean value concepts with the method and provide a real life application.
Resumo:
The present research was carried out at the DER/FCAV, São Paulo State University - Brazil, with the purpose of analyzing the quantity and quality of biogas produced by six types of substrates. The substrates used in the anaerobic digestion were characterized as: 1- Litter of broiler (LB); 2- Grinded broiler litter (GBL); 3- Broiler litter with wood shavings (BLWS); 4- Grinded broiler litter with wood shavings (GBLWS); 5- Broiler litter with peanut hulls (BLPH); 6- Grinded broiler litter with peanut hull (GBLPH). It was concluded from the collected data that: the (GBL) substrate showed a superior biogas accumulated production in relation to the other substrates, while the BLWS presented an inferior accumulated production; the grinded substrates showed higher quantities of accumulated biogas in relation to the non-grinded substrates, except for GBLPH, with 20.9 m³ inferior than BLPH; the period of maximum biogas production started from 45 to 60 days, declining after 120 days; at 57 days after filling up the digesters the biogas produced had levels of CH4 superior than 53%, and from 99 days all of them produced biogas with levels of CH4 superior than 70%; LB and GBL presented higher concentrations of CH4 in the biogas.