506 resultados para polyurethane


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to investigate physical performance of particleboards produced with waste from sawmills, containing different wood species, and two adhesives: urea-formaldehyde (UF) based resin and castor-oil (PU) based bi-component polyurethane resin. Panels were produced with nominal density 0.8gcm(-3); pressing temperature 110 degrees C; pressing time 10 min; specific pressure 5 MPa. Water absorption (2 and 24h); thickness swelling (2 and 24h); density; and moisture content were investigated. Results confirmed that the produced panels presented compatible physical properties in comparison with other researches referred in literature, proving the feasibility of inputs employed. Panels produced PU showed better performance than those produced with UF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structural health monitoring (SHM) refers to the procedure of assessing the structure conditions continuously so it is an alternative to conventional nondestructive evaluation (NDE) techniques [1]. With the growing developments in sensor technology acoustic emission (AE) technology has been attracting attention in SHM applications. AE are characterized by waves produced by the sudden internal stress redistribution caused by the changes in the internal structure, such as fatigue, crack growth, corrosion, etc. Piezoelectric materials such as Lead Zirconate Titanate (PZT) ceramic have been widely used as sensor due to its high electromechanical coupling factor and piezoelectric d coefficients. Because of the poor mechanical characteristic and the lack in the formability of the ceramic, polymer matrix-based piezoelectric composites have been studied in the last decade in order to obtain better properties in comparison with a single phase material. In this study a composite film made of polyurethane (PU) and PZT ceramic particles partially recovered with polyaniline (PAni) was characterized and used as sensor for AE detection. Preliminary results indicate that the presence of a semiconductor polymer (PAni) recovering the ceramic particles, make the poling process easier and less time consuming. Also, it is possible to observe that there is a great potential to use such type of composite as sensor for structure health monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps.Purpose. The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by cementing titanium cylinders to the prefabricated framework (group CTF). This procedure was developed to correct the misfit between frameworks and loaded implants.Material and methods. Four internal hexagon cylindrical implants were placed 10 mm apart in a polyurethane block by using the surgical guides of the corresponding implant system. Previously fabricated titanium frameworks (n=10) were divided into 2 groups. In group STF, prefabricated machined frameworks were used (n=5), and, in group CTF, the frameworks were fabricated by using a passive fit procedure, which was developed to correct the misfit between the cast titanium frameworks and supporting dental implants (n=5). Both groups were screw-retained under torque control (10 Ncm). Six strain gauges were placed on the upper surface of the polyurethane block, and 3 strain measurements were recorded for each framework. Data were analyzed with the Student t test (alpha=.05).Results. The mean microstrain values between the framework and the implants were significantly higher for group STF (2517 me) than for group CTF (844 me) (P<.05).Conclusions. Complete-arch implant frameworks designed for load application and fabricated by using the passive fit procedure decreased the strain between the frameworks and implants more than 1 piece prefabricated machined frameworks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The industrial development has created many environmental problems that can be observed through the changes in air, soil and water. The pollution of water bodies with compounds present in textile effluents cause beyond the visual pollution, changes in biological cycles, mainly by changing the process of photosynthesis. Due to these environmental implications it is necessary a treatment of livestock manure. The process of adsorption of the dye is a technique that has been successfully employed for effective removal of the color of the effluent. The purpose of this study was to investigate the application of a polyurethane foam plant of castor oil as an alternative adsorbent for removal of dyes in textile effluents. The study was conducted with the dye “luganil azul”, as adsorbent and the foam in a flexible manner and sprayed. It also investigated the influence of pH on the adsorption dye. The kinetic data were obtained, noting that the pH influence on adsorption. Adsorption isotherms of the dye in aqueous solution using the foam in a flexible manner also were determined experimentally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Products derived from wood or engineered products are becoming interesting alternatives to the replacement of solid wood in various applications, from structural components to the furniture industry and packaging. Among these products, there are panels built by strands, particles and fibers, each one having their particular characteristics and potential of use. Since the different types of panels are produced, waste generation is part of the process, and that more technological it is, it still generates losses of raw materials. Based on the need for rational use of raw materials and using almost full of industrially processed wood, It arises the proposal of this work, which seeks to use waste from the lamination, like pieces of strands, broken strands, strands rough, cracked strands to produce panels with structural characteristics of the OSL panel (Oriented Strand Lumber), LSL (Laminated Strand Lumber) and OSB (Oriented Strand Lumber). Besides the use of waste, this paper seeks an alternative to the use of the adhesive, because the industry uses formaldehyde-based adhesives, which over the press, they emit large amounts of formaldehyde, which is very aggressive to humans and environment. The panels made with polyurethane resin based on castor oil and hot-pressed were characterized by physical and mechanical tests according to specifications of European Standard (EN). High values of tensile strength, elastic modulus and density were found in the results of tests. Adding to stable values of swelling and moisture content, the panel studied adds attractive features to the panel market, especially in the civil construction

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to complications caused by metallic implants in the replacement of bone tissue, the biological application of ceramics raised and became a viable alternative. The titania has the ability to promote bone tissue regeneration based on its structure, mechanical and biologically properties compatibility. The present work aims at obtaining and characterization of Titania (TiO2) porous ceramics produced by the polymeric sponge method (replica method). Polyurethane sponge with 10 ppi and 15 ppi (pores per linear inch) were used. The process differentiation is the air blower used to remove excess slurry. The ceramics sponges were dried in an oven, then pre-sintered at 1000 o C and sintered at 1450 o C. The effect of direct sintering at 1450 o C was also assessed. The percentage of solids used to prepare the slurry was 40 to 45% by weight. To increase the surface porosity of the sponge, 20% of starch was added. There was difficulty on controlling the thickness of the slurry layers on the sponge which resulted in the variation of samples mechanical resistance. Despite this, the results obtained are quite promising for the proposed use, indicating that it is possible to obtain titania sponges with an apparent porosity of around 60%, a bulk density ranging from 40 to 47% and a compressive strength resistance – that with better control of layers depositions – can vary from 1 to 4 MPa

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adhesives used in the production of engineered boards have been object of study over the years in order to improve the properties of the boards with less energy consumption, lower production costs and reduced environmental impact. In addition to that, process variables may affect the properties of the board. The present study aimed to characterize sheets of plywood, manufactured with two types of adhesives, under two different pressing conditions. The adhesives used for the study were Phenol-formaldehyde and Polyurethane castor oil based. The pressure of pressing was varied in a range from 75 to 160 Bar, in order to verify how they influence the physical and mechanical properties of the board. The tests performed resulted in a conclusion that shows that the moister content of the veneers interferes on the physical and mechanical tests. In general, boards produced with polyurethane resin showed superior physical and mechanical results; although the ones produced with phenol formaldehyde at a pressure of 75 Bar had always equal or higher values, compared to what is found in literature

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work analyzed the loss of sensible heat from one fluid to be considered homogeneous heat distribution on a thermal reservoir with cylindrical geometries composite insulating layers. We studied two thermal reservoirs with a volume of 20 liters, and the first has a layer thickness of 75 mm of expanding polyurethane foam wrapped in the polycarbonate container and the second container has only layer thickness of 5 mm of polycarbonate, as insulation of fluid of the external environment. The experimental results are compared with theoretical results obtained through a calculation script, displayed and detailed during the work development, from the theory of energy balance. The maximum error introduced between the theoretical and experimental results were 3.5% and 1.4% respectively for the Boilers with or without a polyurethane coating

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this in vitro study was quantify the micro strain development around the internal hexagon implants, varying the type of prosthetic coping. For This reason, three implants of internal hexagon were inserted into one polyurethane block in line placement. Microunit abutments were screwed onto the implants. Tangentially the implants were bonded the strain gauges, two to the center implant. Ten structures, each one containing three copings were cast in Co-Cr alloy, that were divided into groups in the first group, plastic copings were used, and in the second group machined copings were used. The superstructure’s occlusal screws were tightened onto Microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 ± 237,66 and the machined copings were 338,12 ± 223,01. The data were analyzed statistically by t- Student test. No statistically significant difference was found between the prosthetic copings (p= 0,867). It was concluded that to internal hexagon implants in line placement, the type of copings presented similar magnitude of micro strain after prosthetic occlusal screw was tightened

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV