995 resultados para periapical radiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os colaboradores que realizam a sua atividade profissional, no setor das águas residuais, reconhecem que a sua atividade é perigosa. Esse conhecimento, foi adquirido pela experiência obtida ao longo dos anos, pelas várias formações e pelas notícias de acidentes, muitas vezes mortais, que têm acontecido na atividade. Muita das vezes, os colaboradores têm dificuldade em aceitar o risco, porque na realidade não existe um histórico conhecido do que se passa no interior das redes de drenagem de águas residuais e consideram que o risco é apenas teórico. Os portugueses são um Povo muito ligado à Cultura Popular,e são os ditados populares que melhor sintetiza as ideias expressas pelos trabalhador português “Ver para Crer, Como São Tomé” (SOUSA, Marcelo Rebelo de, Os Evangelhos de 2001, Lisboa, Bertrand Editora, 2001]. O objetivo principal com este trabalho, foi evidenciar que existem gases no interior das caixas de visita, mas principalmente, demostrar que seu aparecimento e respetiva concentração, é variável e que ocorre sem aviso prévio! Tornando assim, os trabalhos no interior das caixas de visita e das redes de drenagem de águas residuais domesticas, locais perigosos para quem opera no seu interior, sem a correta utilização dos equipamentos de proteção individual, (Epis e Epc). Sendo necessário, reforçar, a constante informação e formação para a utilização dos equipamentos de proteção individual e coletiva. Com o presente estágio, pretendeu-se iniciar um registo histórico de medições nas redes de drenagem de águas residuais domésticas. Com o resultado das medições que serão obtidas, pretende-se uma “Radiografia Fotográfica” ao interior das caixas de visitas das redes de drenagem de águas residuais. Com os resultados deste estudo, pretende-se contribuir de forma clara e objetiva, para os perigos iminentes que existem efetivamente, no interior das redes de saneamento, com a presença de altas concentrações de gás sulfídrico, nocivo para a vida humana!

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to study the influence of the boundary conditions on low-velocity impact behaviour of carbon-epoxy composite plates. Experimental work and numerical analysis were performed on [04,904]s laminates. The influence of different boundary conditions on the impacted plates was analysed considering rectangular and square plates. The X-radiography was used as a non-destructive technique to evaluate the internal damage caused by impact loading. A three-dimensional numerical analysis was also performed considering progressive damage modelling. The model includes three-dimensional solid elements and interface finite elements including a cohesive mixed-mode damage model, which allows simulating delamination between different oriented layers. It was verified that plate’s boundary conditions have influence on the delaminated area. Good agreement between experimental and numerical analysis for shape, orientation and size of the delamination was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The characteristics of carbon fibre reinforced laminates have widened their use from aerospace to domestic appliances, and new possibilities for their usage emerge almost daily. In many of the possible applications, the laminates need to be drilled for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, damage assessment methods based on data extracted from radiographic images are compared and correlated with mechanical test results—bearing test and delamination onset test—and analytical models. The results demonstrate the importance of an adequate selection of drilling tools and machining parameters to extend the life cycle of these laminates as a consequence of enhanced reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nine cases of tuberculosis (TB) were diagnosed among 800 uremic patients, followed-up during 11 years, a prevalence of 1125%, 2.5 times higher than that in the general population. Six patients (66.7%) had lymph node involvement (4 cervical and 2 mediastinal). Three patients (33.3%) had pulmonary involvement (2 pleuro-pulmonary and 1 bilateral apical pulmonary). Eight patients were undergoing dialysis and 1 was pre-dialytic. The duration of dialysis ranged from 1 to 60 months. Three patients had previously received immunosuppressive drugs for unsuccessful renal transplantation. Daily fever was present in all but one patient; he was asymptomatic and TB was suspected after routine chest radiography. Biopsy was the diagnostic procedure in 7 patients (77.8%), four by direct cervical lymph node biopsy, 2 by mediastinal, performed by mediastinoscopy and 1 by pleural biopsy. In 2 other patients TB was confirmed by the presence of tubercle bacilli; in sputum (1 patient) and in a bronchial flushing specimen (the other patient). Triple therapy was used in all patients (isoniazid and ethambutol in all), plus rifampicin in 8 and streptomycin in 1. One patient had jaundice and another had optical neuritis. Five patients were cured. The other four died during treatment of causes unrelated to TB or its treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ollier Disease and Maffucci Syndrome are two rare diseases that can cause tumors in several organs, having a special predilection for the hand. However, there have been very few reports in the literature focusing on hand manifestations of these diseases. We report the cases of three female patients: one with Ollier Disease, and two other with Maffucci Syndrome. All patients had hand involvement as their initial primary complaint. The Ollier Disease patient developed chondrosarcomas of two digits and had to have these fingers amputated. One of the Maffucci patients died one year after presentation from a brain glioblastoma. These cases emphasize the importance of early diagnosis of Ollier Disease and Maffucci Syndrome, as these two conditions are associated not only to crippling hand deformity, but also to a significant risk of chondrosarcoma, and other malignant tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paracoccidioidomycosis is a common disease in Latin America but it is rare in organ transplant recipient patients. We report on a case of such mycosis in a renal transplant recipient. The patient presented with a large lung cavity on the left lower lobe, a rare radiological presentation of paracoccidioidomycosis. Unusual clinical and radiological manifestations of Paracoccidioides brasiliensis infection can occur in immunocompromised patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extranodal involvement is common in lymphomas associated with human immunodeficiency virus infection (HIV) and acquired immunodeficiency syndrome (AIDS). However, primary pulmonary AIDS-related non-Hodgkin's lymphoma is very rare and only few reports were published in the medical literature. Clinical presentation is nonspecific, with "B" and respiratory symptoms. Also, patients were with advanced immunodeficiency at the time of diagnosis. Generally, chest radiography showed peripheral nodules or cavitary masses. Primary pulmonary lymphoma associated with AIDS is generally a high-grade B-cell non-Hodgkin lymphoma and Epstein-Barr virus is strongly associated with the pathogenesis of these tumors. We report a patient with AIDS and primary pulmonary lymphoma which clinical presentation was a total atelectasis of the left lung.