866 resultados para peak bone mass


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stable carbon isotope analysis of methane (delta C-13 of CH4) on atmospheric samples is one key method to constrain the current and past atmospheric CH4 budget. A frequently applied measurement technique is gas chromatography (GC) isotope ratio mass spectrometry (IRMS) coupled to a combustion-preconcentration unit. This report shows that the atmospheric trace gas krypton (Kr) can severely interfere during the mass spectrometric measurement, leading to significant biases in delta C-13 of CH4, if krypton is not sufficiently separated during the analysis. According to our experiments, the krypton interference is likely composed of two individual effects, with the lateral tailing of the doubly charged Kr-86 peak affecting the neighbouring m/z 44 and partially the m/z 45 Faraday cups. Additionally, a broad signal affecting m/z 45 and especially m/z 46 is assumed to result from scattered ions of singly charged krypton. The introduced bias in the measured isotope ratios is dependent on the chromatographic separation, the krypton-to-CH4 mixing ratio in the sample, the focusing of the mass spectrometer as well as the detector configuration and can amount to up to several per mil in delta C-13. Apart from technical solutions to avoid this interference, we present correction routines to a posteriori remove the bias.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reduced bone stock can result in fractures that mostly occur in the spine, distal radius, and proximal femur. In case of operative treatment, osteoporosis is associated with an increased failure rate. To estimate implant anchorage, mechanical methods seem to be promising to measure bone strength intraoperatively. It has been shown that the mechanical peak torque correlates with the local bone mineral density and screw failure load in hip, hindfoot, humerus, and spine in vitro. One device to measure mechanical peak torque is the DensiProbe (AO Research Institute, Davos, Switzerland). The device has shown its effectiveness in mechanical peak torque measurement in mechanical testing setups for the use in hip, hindfoot, and spine. In all studies, the correlation of mechanical torque measurement and local bone mineral density and screw failure load could be shown. It allows the surgeon to judge local bone strength intraoperatively directly at the region of interest and gives valuable information if additional augmentation is needed. We summarize methods of this new technique, its advantages and limitations, and give an overview of actual and possible future applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies of the sediments of Lake Lucerne have shown that massive subaqueous mass movements affecting unconsolidated sediments on lateral slopes are a common process in this lake, and, in view of historical reports describing damaging waves on the lake, it was suggested that tsunamis generated by mass movements represent a considerable natural hazard on the lakeshores. Newly performed numerical simulations combining two-dimensional, depth-averaged models for mass-movement propagation and for tsunami generation, propagation and inunda- tion reproduce a number of reported tsunami effects. Four analysed mass-movement scenarios—three based on documented slope failures involving volumes of 5.5 to 20.8 9 106 m3—show peak wave heights of several metres and maximum runup of 6 to [10 m in the directly affected basins, while effects in neighbouring basins are less drastic. The tsunamis cause large-scale inundation over distances of several hundred metres on flat alluvial plains close to the mass-movement source areas. Basins at the ends of the lake experience regular water-level oscillations with characteristic periods of several minutes. The vulnerability of potentially affected areas has increased dramatically since the times of the damaging historical events, recommending a thorough evaluation of the hazard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

UNLABELLED Treatment effects over 2 years of teriparatide vs. ibandronate in postmenopausal women with osteoporosis were compared using lumbar spine bone mineral density (BMD) and trabecular bone score (TBS). Teriparatide induced larger increases in BMD and TBS compared to ibandronate, suggesting a more pronounced effect on bone microarchitecture of the bone anabolic drug. INTRODUCTION The trabecular bone score (TBS) is an index of bone microarchitecture, independent of bone mineral density (BMD), calculated from anteroposterior spine dual X-ray absorptiometry (DXA) scans. The potential role of TBS for monitoring treatment response with bone-active substances is not established. The aim of this study was to compare the effects of recombinant human 1-34 parathyroid hormone (teriparatide) and the bisphosphonate ibandronate (IBN), on lumbar spine (LS) BMD and TBS in postmenopausal women with osteoporosis. METHODS Two patient groups with matched age, body mass index (BMI), and baseline LS BMD, treated with either daily subcutaneous teriparatide (N = 65) or quarterly intravenous IBN (N = 122) during 2 years and with available LS BMD measurements at baseline and 2 years after treatment initiation were compared. RESULTS Baseline characteristics (overall mean ± SD) were similar between groups in terms of age 67.9 ± 7.4 years, body mass index 23.8 ± 3.8 kg/m(2), BMD L1-L4 0.741 ± 0.100 g/cm(2), and TBS 1.208 ± 0.100. Over 24 months, teriparatide induced a significantly larger increase in LS BMD and TBS than IBN (+7.6 % ± 6.3 vs. +2.9 % ± 3.3 and +4.3 % ± 6.6 vs. +0.3 % ± 4.1, respectively; P < 0.0001 for both). LS BMD and TBS were only weakly correlated at baseline (r (2) = 0.04) with no correlation between the changes in BMD and TBS over 24 months. CONCLUSIONS In postmenopausal women with osteoporosis, a 2-year treatment with teriparatide led to a significantly larger increase in LS BMD and TBS than IBN, suggesting that teriparatide had more pronounced effects on bone microarchitecture than IBN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The length of the dry period in commercial dairy production is under close scrutiny. While the main concern is the composition and volume of milk produced, the evaluation of colostrum quality under these new paradigms has suggested a decline in IgG concentrations, while some reports indicate no change. Colostrum quality has been defined as an adequate concentration (>50 mg/ml) of immunoglobulin in the secretions to provide the newborn with maximal disease resistance. We investigated the appearance of IgG in mammary pre- and post partum secretions in cows without a dry period (continuously milked, Dry0) and compared the secretions with cows that experienced a dry period of 60 d (Dry60). Blood was collected during the experimental period and plasma analysed for progesterone (P4) and prolactin (Prl). Approximately -6 d relative to parturition, the Dry0 animals exhibited increased concentration of IgG in their secretions to an average of ∼35 mg/ml that remained rather constant through subsequent pregnancy and following parturition. Dry0 cows were producing an average IgG concentration in parturition colostrum of 44·2±17·6 mg/ml that was not different than that of controls (66·86±16·8 mg/ml). However, Dry0 cows exhibited high variation, different peak times (day) of IgG concentration including times that occurred both pre and post parturition. IgG mass of the Dry0 cows remained rather constant pre- and post partum and did not show the same declining mass following parturition that was shown for the Dry60 cows. The change in plasma P4 and Prl were shown to have no timing effect on colostrum IgG concentration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupolemass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system. When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quadrupole mass spectrometer (QMS) has over 30 years of spaceflight heritage in making important neutral gas and low energy ion observations. Given their geometrical constraints, these instruments are currently operated at the extreme limit of their capabilities. However, a technique called higher order auxiliary excitation provides a set of novel, robust, electronics-based solutions for improving the performance of these sensors. By driving the quadrupole rods with an additional frequency nearly twice that of the normal RF operating frequency, substantially increased abundance sensitivity, maximum attainable mass resolution, and peak stability can be achieved through operation of voltage scan lines through the center of formed upper stability islands. Such improvements are modeled using numerical simulations of ion trajectories in a quadrupole field with and without applied higher order auxiliary excitation. When compared to a traditional QMS with a mass range up to 500Da, sensors can be designed with the same precision electronics to have expected mass ranges beyond 1500Da with a power increase of less than twice that of its heritage implementations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stable isotope analysis was performed on the structural carbonate of fish bone apatite from early and early middle Eocene samples (~55 to ~45 Ma) recently recovered from the Lomonosov Ridge by Integrated Ocean Drilling Program Expedition 302 (the Arctic Coring Expedition). The d18O values of the Eocene samples ranged from -6.84 per mil to -2.96 per mil Vienna Peedee belemnite, with a mean value of -4.89 per mil, compared to 2.77 per mil for a Miocene sample in the overlying section. An average salinity of 21 to 25 per mil was calculated for the Eocene Arctic, compared to 35 per mil for the Miocene, with lower salinities during the Paleocene Eocene thermal maximum, the Azolla event at ~48.7 Ma, and a third previously unidentified event at ~47.6 Ma. At the Azolla event, where the organic carbon content of the sediment reaches a maximum, a positive d13C excursion was observed, indicating unusually high productivity in the surface waters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mass-accumulation rate (MAR) of the non-authigenic, inorganic, crystalline component of deep-sea sediments from the Pacific aseismic rises apparently reflects influx of eolian sediment. The eolian sediment usually is dominated by volcanic material, except during glacial times. Sediments from Hess Rise provide a discontinuous record of eolian MARs. During Albian to Cenomanian time, the influx of volcanic material was fairly high (0.35-0.6 g/cm**2/10**3 yr), recording the latest stages of the Albian volcanism that formed Hess Rise. From the Campanian through the Paleocene, influx of eolian sediment was low, averaging 0.03 g/cm**2/10**3 yr. None of the four Hess Rise drill sites show evidence of the Late Cretaceous volcanic episode recorded at many sites now in the equatorial to subtropical Pacific. Pliocene to Pleistocene samples record a peak in volcanic influx about 4 to 5 m.y. ago, which has been well documented elsewhere. The several-fold increase in eolian accumulation rates elsewhere which are correlated with the onset of severe northernhemisphere glaciation 2.5 m.y. ago is not obvious in the Hess Rise data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Summary: Serum 25(OH)D levels decline without sunlight exposure. We studied 120 expeditioners to Antarctica to determine the skeletal and hormonal responses to sunlight deprivation. With emerging vitamin D insufficiency, serum calcium decreased, PTH increased, and bone loss at the proximal femur was observed. Baseline serum 25(OH)D levels >100 nmol/L prevented vitamin D insufficiency. Introduction: Vitamin D stores deplete without adequate sunlight exposure unless supplementation is provided. We studied 120 healthy adults who spent a year in Antarctica as a model for sunlight deprivation to define the timing and magnitude of the skeletal and hormonal responses to emerging vitamin D insufficiency. Methods: Fasting blood samples were assessed at baseline, 6 and 12 months for serum 25-hydroxyvitamin D (25(OH)D), osteocalcin (OC), bone formation (P1NP) and resorption (CTx), PTH and calcium. Lumbar spine and proximal femur BMD was measured using DXA. Differences over time were determined using repeated measures ANOVA. Percent changes were expressed as (Delta value/(value A +value B)/2)x100. Relationships between outcome measures were determined using Spearman's correlations. Results: Vitamin D insufficiency (<50 nmol/L) was observed in 85% of expeditioners by 6 months when serum calcium decreased and PTH increased (p<0.01). By 12 months, OC increased by 7.4±3.0% (p<0.05), and BMD decreased by 1.0±2.0% at the total proximal femur (p<0.05). For those with vitamin D sufficiency at baseline (>50 nmol/L), sunlight deprivation produced vitamin D insufficiency within 4 months unless baseline values were >100 nmol/L. Conclusion: Supplementation may be necessary for expeditioners with limited access to UV light.