935 resultados para human expert cognition, real-time trajectory planning, autonomous UAS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work annealing and growth of CuInS2 thin films is investigated with quasireal-time in situ Raman spectroscopy. During the annealing a shift of the Raman A1 mode towards lower wave numbers with increasing temperature is observed. A linear temperature dependence of the phonon branch of ¿2 cm¿1/100 K is evaluated. The investigation of the growth process (sulfurization of metallic precursors) with high surface sensitivity reveals the occurrence of phases which are not detected with bulk sensitive methods. This allows a detailed insight in the formation of the CuInS2 phases. Independent from stoichiometry and doping of the starting precursors the CuAu ordering of CuInS2 initially forms as the dominating ordering. The transformation of the CuAu ordering into the chalcopyrite one is, in contrast, strongly dependent on the precursor composition and requires high temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Given the low sensitivity of amoebal coculture, we developed a specific real-time PCR for the detection of Parachlamydia. The analytical sensitivity was high, and the inter- and intrarun variabilities were low. When the PCR was applied to nasopharyngeal aspirates, it was positive for six patients with bronchiolitis. Future studies should assess the role of Parachlamydia in bronchiolitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laajojen pintojen kuvaaminen rajoitetussa työskentelytilassa riittävällä kuvatarkkuudella voi olla vaikeaa. Kuvaaminen on suoritettava osissa ja osat koottava saumattomaksi kokonaisnäkymäksi eli mosaiikkikuvaksi. Kuvauslaitetta käsin siirtelevän käyttäjän on saatava välitöntä palautetta, jotta mosaiikkiin ei jäisi aukkoja ja työ olisi nopeaa. Työn tarkoituksena oli rakentaa pieni, kannettava ja tarkka kuvauslaite paperi- ja painoteollisuuden tarpeisiin sekä kehittää palautteen antamiseen menetelmä, joka koostaaja esittää karkeaa mosaiikkikuvaa tosiajassa. Työssä rakennettiin kaksi kuvauslaitetta: ensimmäinen kuluttajille ja toinen teollisuuteen tarkoitetuista osista. Kuvamateriaali käsiteltiin tavallisella pöytätietokoneella. Videokuvien välinen liike laskettiin yksinkertaisella seurantamenetelmällä ja mosaiikkikuvaa koottiin kameroiden kuvanopeudella. Laskennallista valaistuksenkorjausta tutkittiin ja kehitetty menetelmä otettiin käyttöön. Ensimmäisessä kuvauslaitteessa on ongelmia valaistuksen ja linssivääristymien kanssa tuottaen huonolaatuisia mosaiikkikuvia. Toisessa kuvauslaitteessa nämä ongelmat on korjattu. Seurantamenetelmä toimii hyvin ottaen huomioon sen yksinkertaisuuden ja siihen ehdotetaan monia parannuksia. Työn tulokset osoittavat, että tosiaikainen mosaiikkikuvan koostaminen megapikselin kuvamateriaalista on mahdollista kuluttajille tarkoitetulla tietokonelaitteistolla.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Colorectal cancer (CRC) is the second leading cause of cancer-related death in developed countries. Early detection of CRC leads to decreased CRC mortality. A blood-based CRC screening test is highly desirable due to limited invasiveness and high acceptance rate among patients compared to currently used fecal occult blood testing and colonoscopy. Here we describe the discovery and validation of a 29-gene panel in peripheral blood mononuclear cells (PBMC) for the detection of CRC and adenomatous polyps (AP). Blood samples were prospectively collected from a multicenter, case-control clinical study. First, we profiled 93 samples with 667 candidate and 3 reference genes by high throughput real-time PCR (OpenArray system). After analysis, 160 genes were retained and tested again on 51 additional samples. Low expressed and unstable genes were discarded resulting in a final dataset of 144 samples profiled with 140 genes. To define which genes, alone or in combinations had the highest potential to discriminate AP and/or CRC from controls, data were analyzed by a combination of univariate and multivariate methods. A list of 29 potentially discriminant genes was compiled and evaluated for its predictive accuracy by penalized logistic regression and bootstrap. This method discriminated AP >1cm and CRC from controls with a sensitivity of 59% and 75%, respectively, with 91% specificity. The behavior of the 29-gene panel was validated with a LightCycler 480 real-time PCR platform, commonly adopted by clinical laboratories. In this work we identified a 29-gene panel expressed in PBMC that can be used for developing a novel minimally-invasive test for accurate detection of AP and CRC using a standard real-time PCR platform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reproductive traits play a key role in pig production in order to reduce costs and increase economic returns. Among others, gene expression analyses represent a useful approach to study genetic mechanisms underlying reproductive traits in pigs. The application of reverse-transcription quantitative PCR requires the selection of appropriate reference genes, whose expression levels should not be affected by the experimental conditions, especially when comparing gene expression across different physiological stages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IP-verkkojen hyvin tunnettu haitta on, että nämä eivät pysty takaamaan tiettyä palvelunlaatua (Quality of Service) lähetetyille paketeille. Seuraavat kaksi tekniikkaa pidetään lupaavimpina palvelunlaadun tarjoamiselle: Differentiated Services (DiffServ) ja palvelunlaatureititys (QoS Routing). DiffServ on varsin uusi IETF:n määrittelemä Internetille tarkoitettu palvelunlaatumekanismi. DiffServ tarjoaa skaalattavaa palvelujen erilaistamista ilman viestintää joka hypyssä ja per-flow –tilan ohjausta. DiffServ on hyvä esimerkki hajautetusta verkkosuunnittelusta. Tämän palvelutasomekanismin tavoite on viestintäjärjestelmien suunnittelun yksinkertaistaminen. Verkkosolmu voidaan rakentaa pienestä hyvin määritellystä rakennuspalikoiden joukosta. Palvelunlaatureititys on reititysmekanismi, jolla liikennereittejä määritellään verkon käytettävissä olevien resurssien pohjalta. Tässä työssä selvitetään uusi palvelunlaatureititystapa, jota kutsutaan yksinkertaiseksi monitiereititykseksi (Simple Multipath Routing). Tämän työn tarkoitus on suunnitella palvelunlaatuohjain DiffServille. Tässä työssä ehdotettu palvelunlaatuohjain on pyrkimys yhdistää DiffServ ja palvelunlaatureititysmekanismeja. Työn kokeellinen osuus keskittyy erityisesti palvelunlaatureititysalgoritmeihin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Adequate empirical antibiotic dose selection for critically ill burn patients is difficult due to extreme variability in drug pharmacokinetics. Therapeutic drug monitoring (TDM) may aid antibiotic prescription and implementation of initial empirical antimicrobial dosage recommendations. This study evaluated how gradual TDM introduction altered empirical dosages of meropenem and imipenem/cilastatin in our burn ICU. METHODS: Imipenem/cilastatin and meropenem use and daily empirical dosage at a five-bed burn ICU were analyzed retrospectively. Data for all burn admissions between 2001 and 2011 were extracted from the hospital's computerized information system. For each patient receiving a carbapenem, episodes of infection were reviewed and scored according to predefined criteria. Carbapenem trough serum levels were characterized. Prior to May 2007, TDM was available only by special request. Real-time carbapenem TDM was introduced in June 2007; it was initially available weekly and has been available 4 days a week since 2010. RESULTS: Of 365 patients, 229 (63%) received antibiotics (109 received carbapenems). Of 23 TDM determinations for imipenem/cilastatin, none exceeded the predefined upper limit and 11 (47.8%) were insufficient; the number of TDM requests was correlated with daily dose (r=0.7). Similar numbers of inappropriate meropenem trough levels (30.4%) were below and above the upper limit. Real-time TDM introduction increased the empirical dose of imipenem/cilastatin, but not meropenem. CONCLUSIONS: Real-time carbapenem TDM availability significantly altered the empirical daily dosage of imipenem/cilastatin at our burn ICU. Further studies are needed to evaluate the individual impact of TDM-based antibiotic adjustment on infection outcomes in these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Teollusuussovelluksissa vaaditaan nykyisin yhä useammin reaaliaikaista tiedon käsittelyä. Luotettavuus on yksi tärkeimmistä reaaliaikaiseen tiedonkäsittelyyn kykenevän järjestelmän ominaisuuksista. Sen saavuttamiseksi on sekä laitteisto, että ohjelmisto testattava. Tämän työn päätavoitteena on laitteiston testaaminen ja laitteiston testattavuus, koska luotettava laitteistoalusta on perusta tulevaisuuden reaaliaikajärjestelmille. Diplomityössä esitetään digitaaliseen signaalinkäsittelyyn soveltuvan prosessorikortin suunnittelu. Prosessorikortti on tarkoitettu sähkökoneiden ennakoivaa kunnonvalvontaa varten. Uusimmat DFT (Desing for Testability) menetelmät esitellään ja niitä sovelletaan prosessorikortin sunnittelussa yhdessä vanhempien menetelmien kanssa. Kokemukset ja huomiot menetelmien soveltuvuudesta raportoidaan työn lopussa. Työn tavoitteena on kehittää osakomponentti web -pohjaiseen valvontajärjestelmään, jota on kehitetty Sähkötekniikan osastolla Lappeenrannan teknillisellä korkeakoululla.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reaaliaikaisten käyttöjärjestelmien käyttö sulautetuissa järjestelmissä on kasvamassa koko ajan. Sulautettuja tietokoneita käytetään yhä useammassa kohteessa kuten sähkökäyttöjen ohjauksessa. Sähkökäyttöjen ohjaus hoidetaan nykyisin yleensä nopealla digitaalisella signaaliprosessorilla (DSP), jolloin ohjelmointi ja päivittäminen on hidasta ja vaikeaa johtuen käytettävästä matalan tason Assembler-kielestä. Ratkaisuna yleiskäyttöisten prosessorien ja reaaliaikakäyttöjärjestelmien käyttö. Kaupalliset reaaliaikakäyttöjärjestelmät ovat kalliita ja lähdekoodin saaminen omaan käyttöön jopa mahdotonta. Linux on ei-kaupallinen avoimen lähdekoodin käyttöjärjestelmä, joten sen käyttö on ilmaista ja sitä voi muokata vapaasti. Linux:iin on saatavana useita laajennuksia, jotka tekevät siitä reaaliaikaisen käyttöjärjestelmän. Vaihtoehtoina joko kova (hard) tai pehmeä (soft) reaaliaikaisuus. Linux:iin on olemassa valmiita kehitysympäristöjä mutta ne kaipaavat parannusta ennen kuin niitä voidaan käyttää suuressa mittakaavassa teollisuudessa. Reaaliaika Linux ei sovellus nopeisiin ohjauslooppeihin (<100 ms) koska nopeus ei riitä vielä mutta nopeus kasvaa samalla kun prosessorit kehittyvät. Linux soveltuu hyvin rajapinnaksi nopean ohjauksen ja käyttäjän välille ja hitaampaan ohjaukseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among 112 patients infected only by Plasmodium falciparum, WHO criteria of severity were compared with parasite load assessed by microscopy and quantitative PCR. Clinical severity was significantly correlated with higher parasite load as determined by microscopy (p < 0.001) and by PCR (p < 0.001). Hence, quantitative PCR might be useful to predict outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Online paper web analysis relies on traversing scanners that criss-cross on top of a rapidly moving paper web. The sensors embedded in the scanners measure many important quality variables of paper, such as basis weight, caliper and porosity. Most of these quantities are varying a lot and the measurements are noisy at many different scales. The zigzagging nature of scanning makes it difficult to separate machine direction (MD) and cross direction (CD) variability from one another. For improving the 2D resolution of the quality variables above, the paper quality control team at the Department of Mathematics and Physics at LUT has implemented efficient Kalman filtering based methods that currently use 2D Fourier series. Fourier series are global and therefore resolve local spatial detail on the paper web rather poorly. The target of the current thesis is to study alternative wavelet based representations as candidates to replace the Fourier basis for a higher resolution spatial reconstruction of these quality variables. The accuracy of wavelet compressed 2D web fields will be compared with corresponding truncated Fourier series based fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status