961 resultados para high vaccine dose
Resumo:
A non-controlled longitudinal study was conducted to evaluate the combined vaccine against measles, mumps and rubella (MMR) immunogenicity in 150 children vaccinated in the routine of three health units in the city of Rio de Janeiro, Brazil, 2008-2009, without other vaccines administered during the period from 30 days before to 30 days after vaccination. A previous study conducted in Brazil in 2007, in 1,769 children ranging from 12-15 months of age vaccinated against yellow fever and MMR simultaneously or at intervals of 30 days or more between doses, had shown low seroconversion for mumps regardless of the interval between administration of the two vaccines. The current study showed 89.5% (95% confidence interval: 83.3; 94.0) seroconversion rate for mumps. All children seroconverted for measles and rubella. After revaccination, high antibody titres and seroconversion rates were achieved against mumps. The results of this study and others suggest that two MMR doses confer optimal immunoresponses for all three antigens and the possible need for additional doses should be studied taking into account not only serological, but also epidemiological data, as there is no serological correlate of protection for mumps.
Resumo:
BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.
Resumo:
The recommended treatment for latent tuberculosis (TB) infection in adults is a daily dose of isoniazid (INH) 300 mg for six months. In Brazil, INH was formulated as 100 mg tablets. The treatment duration and the high pill burden compromised patient adherence to the treatment. The Brazilian National Programme for Tuberculosis requested a new 300 mg INH formulation. The aim of our study was to compare the bioavailability of the new INH 300 mg formulation and three 100 mg tablets of the reference formulation. We conducted a randomised, single dose, open label, two-phase crossover bioequivalence study in 28 healthy human volunteers. The 90% confidence interval for the INH maximum concentration of drug observed in plasma and area under the plasma concentration vs. time curve from time zero to the last measurable concentration “time t” was 89.61-115.92 and 94.82-119.44, respectively. The main limitation of our study was that neither adherence nor the safety profile of multiple doses was evaluated. To determine the level of INH in human plasma, we developed and validated a sensitive, simple and rapid high-performance liquid chromatography-tandem mass spectrometry method. Our results showed that the new formulation was bioequivalent to the 100 mg reference product. This finding supports the use of a single 300 mg tablet daily strategy to treat latent TB. This new formulation may increase patients’ adherence to the treatment and quality of life.
Resumo:
BACKGROUND: Antiretroviral therapy (ART) containing tenofovir disoproxil fumarate (TDF) and didanosine (ddI) has been associated with poor immune recovery despite virologic success. This effect might be related to ddI toxicity since ddI exposure is substantially increased by TDF. OBJECTIVE: To analyze whether immune recovery during ART with TDF and ddI is ddI-dose dependent. DESIGN AND METHODS: A retrospective longitudinal analysis of immune recovery measured by the CD4 T-cell slope in 614 patients treated with ART containing TDF with or without ddI. Patients were stratified according to the tertiles of their weight-adjusted ddI dose: low dose (< 3.3 mg/kg), intermediate dose (3.3-4.1 mg/kg) and high dose (> 4.1 mg/kg). Cofactors modifying the degree of immune recovery after starting TDF-containing ART were identified by univariable and multivariable linear regression analyses. RESULTS: CD4 T-cell slopes were comparable between patients treated with TDF and a weight-adjusted ddI-dose of < 4.1 mg/kg per day (n = 143) versus TDF-without-ddI (n = 393). In the multivariable model the slopes differed by -13 CD4 T cells/mul per year [95% confidence interval (CI), -42 to 17; P = 0.40]. In contrast, patients treated with TDF and a higher ddI dose (> 4.1 mg/kg per day, n = 78) experienced a significantly impaired immune recovery (-47 CD4 T cells/microl per year; 95% CI, -82 to -12; P = 0.009). The virologic response was comparable between the different treatment groups. CONCLUSIONS: Immune recovery is impaired, when high doses of ddI (> 4.1 mg/kg) are given in combination with TDF. If the dose of ddI is adjusted to less than 4.1 mg/kg per day, immune recovery is similar to other TDF-containing ART regimen.
Resumo:
The generation of vaccines against HIV/AIDS able to induce long-lasting protective immunity remains a major goal in the HIV field. The modest efficacy (31.2%) against HIV infection observed in the RV144 phase III clinical trial highlighted the need for further improvement of HIV vaccine candidates, formulation, and vaccine regimen. In this study, we have generated two novel NYVAC vectors, expressing HIV-1 clade C gp140(ZM96) (NYVAC-gp140) or Gag(ZM96)-Pol-Nef(CN54) (NYVAC-Gag-Pol-Nef), and defined their virological and immunological characteristics in cultured cells and in mice. The insertion of HIV genes does not affect the replication capacity of NYVAC recombinants in primary chicken embryo fibroblast cells, HIV sequences remain stable after multiple passages, and HIV antigens are correctly expressed and released from cells, with Env as a trimer (NYVAC-gp140), while in NYVAC-Gag-Pol-Nef-infected cells Gag-induced virus-like particles (VLPs) are abundant. Electron microscopy revealed that VLPs accumulated with time at the cell surface, with no interference with NYVAC morphogenesis. Both vectors trigger specific innate responses in human cells and show an attenuation profile in immunocompromised adult BALB/c and newborn CD1 mice after intracranial inoculation. Analysis of the immune responses elicited in mice after homologous NYVAC prime/NYVAC boost immunization shows that recombinant viruses induced polyfunctional Env-specific CD4 or Gag-specific CD8 T cell responses. Antibody responses against gp140 and p17/p24 were elicited. Our findings showed important insights into virus-host cell interactions of NYVAC vectors expressing HIV antigens, with the activation of specific immune parameters which will help to unravel potential correlates of protection against HIV in human clinical trials with these vectors. IMPORTANCE: We have generated two novel NYVAC-based HIV vaccine candidates expressing HIV-1 clade C trimeric soluble gp140 (ZM96) and Gag(ZM96)-Pol-Nef(CN54) as VLPs. These vectors are stable and express high levels of both HIV-1 antigens. Gag-induced VLPs do not interfere with NYVAC morphogenesis, are highly attenuated in immunocompromised and newborn mice after intracranial inoculation, trigger specific innate immune responses in human cells, and activate T (Env-specific CD4 and Gag-specific CD8) and B cell immune responses to the HIV antigens, leading to high antibody titers against gp140. For these reasons, these vectors can be considered vaccine candidates against HIV/AIDS and currently are being tested in macaques and humans.
Resumo:
RESUME Le cancer du col de l'utérus, deuxième cause de mort par cancer chez la femme, a pu être associé à une infection par plusieurs types de virus du Papillome Humain (HPV), et en particulier HPV 16. Les vaccins prophylactiques sont efficaces à prévenir le cancer du col utérin alors que les lésions de haut grade sont généralement traitées par ablation chirurgicale et par d'éventuels traitements additionnels. Les risques de récurrence liés aux ablations et le taux de mortalité (50%) lié au cancer, démontrent le besoin de développer des stratégies alternatives afin de cibler les lésions précancéreuses. A ce jour, les vaccins thérapeutiques ont démontré peu de résultats cliniques, contrastant avec les régressions de tumeurs ectopiques observées après vaccination dans des modèles murins avec tumeurs associées à HPV. L'induction de réponses immunitaires protectrices dans la muqueuse génitale semble être cruciale pour l'efficacité des vaccins thérapeutiques HPV et évaluer leur efficacité dans un modèle murin avec tumeurs-HPV génitales représente un pré-requis important avant de procéder à des études cliniques. Par conséquent, nous avons établi un modèle murin orthotopique où des tumeurs se développent dans (a muqueuse génitale après une instillation intra-vaginale (i.vag) de cellules tumorales exprimant les oncogènes E6/E7 d'HPV 16 et transduites par un vecteur lentiviral codant la luciferase afin de suivre le développement de ces tumeurs in vivo par imagerie. La caractérisation histologique a démontré que les tumeurs grandissaient dans l'épithélium vaginal et en accord avec leur localisation, des cellules Τ CD8 spécifiques à E7 induites par la tumeur n'étaient détectées que dans la muqueuse génitale et les ganglions drainants. Une infiltration de cellules Τ régulatrices a aussi été mise en évidence, empêchant la régression spontanée de ces tumeurs. Par conséquent, ce modèle devrait être plus adéquat pour tester des stratégies thérapeutiques, étant donné qu'il partage certaines similarités immunologiques avec les lésions génitales naturelles causées par HPV. Etant donné que les oncogènes E6 et E7 d'HPV sont nécessaires à la maintenance du phénotype cancéreux des cellules cervicales, elles représentent des antigènes cibles pour la vaccination thérapeutique. Nous avons démontré que des souris immunisées par voie sous-cutanée (s.c.) avec une dose d'un vaccin à base de polypeptide E7 d'HPV 16 et d'adjuvants, présentaient de nombreuses cellules Τ CD8 sécrétant de l'IFN-γ spécifiquement à E7 dans leurs organes lymphatiques mais également dans la muqueuse génitale. De plus, le manque de corrélation entre les réponses spécifiques mesurées dans la périphérie et dans la muqueuse génitale souligne la nécessité et l'importance de déterminer les réponses immunitaires localement là où les lésions dues à HPV se développent. Si une vaccination par voie muqueuse est plus propice à traiter/régresser des infections génitales/tumeurs que le voie parentérale est un sujet débattu. Nos données montrent que seule la voie s.c. était capable de régresser la quasi totalité des tumeurs génitales chez la souris bien que des réponses CD8 spécifiques à E7 similaires étaient mesurées dans la muqueuse génitale après des vaccinations intra-nasale et i.vag. Afin d'augmenter la réponse spécifique au vaccin dans la muqueuse génitale, des immunostimulants ont été administrés par voie i.vag après vaccination. Nous avons démontré qu'une application i.vag d'agonistes des Toll like receptors après une vaccination s.c. induisait de manière significative une augmentation des cellules Τ CD8 sécrétant de l'IFN-γ spécifiquement à E7 dans la muqueuse génitale. Plus précisément et concernant les CpG et Poly l:C, l'effet était probablement associé à une attraction locale des cellules Τ CD8 et deuxièmement dépendait respectivement des voies de signalisation TLR9 et TLR3/Mda5. Finalement, cette stratégie combinatoire a permis de régresser des grosses tumeurs génitales chez la souris, suggérant qu'une telle immunothérapie pourrait adéquatement traiter des lésions dues à HPV chez les femmes. SUMMARY Cervical cancer is the second leading cause of cancer mortality in women worldwide and results from an infection with a subset of Human Papillomavirus (HPV), HPV 16 representing the most prevalent type. The available prophylactic vaccines are an effective strategy to prevent cervical cancer while already established high grade lesions usually require surgical ablation of lesion with possible additional treatments. Recurrence risks linked to conventional ablations and the high mortality (50%) related to cervical cancer demonstrate the need for alternative strategies like immunotherapies to target pre¬cancerous lesions. Until now, therapeutic vaccines only showed limited clinical results, which strongly contrast with the regression of ectopic tumors observed in the available murine HPV tumor models after vaccination. Induction of protective immune responses in the genital mucosa (GM) may be crucial for efficacy of HPV therapeutic vaccines and evaluating their efficacy in a murine model with genital HPV- tumors represents an important prerequisite for clinical trials. Thus, we have here established an orthotopic mouse model where tumors in the GM develop after an intravaginal (i.vag) instillation of HPV 16 E6/E7 oncogenes-expressing tumor cells transduced with a luciferase encoding lentivirus vector for in vivo imaging of tumor growth. Histological characterization showed that tumor grew within the vaginal epithelium and according to their mucosal location tumor- induced E7-specific CD8 Τ cells were restricted to the GM and genital draining lymph nodes together with high Τ regulatory cells infiltrates preventing spontaneous regression. Consequently, sharing several immunological similarities with natural genital HPV lesions, this novel genital tumor model may be more adequate to test therapeutic strategies. As E6 and/or E7 HPV oncogenes expression is required for the maintenance of the cancerous phenotype of cervical cells, they represent target antigens for therapeutic vaccination. We reported that mice subcutaneously (s.c.) immunized once with an adjuvanted HPV 16 E7 polypeptide vaccine harbored high E7-specific IFN-γ secreting CD8 Τ cells in their lymphoid organs and more importantly in the GM. In addition, the lack of correlation between specific responses measured in the periphery with those measured in the GM highlighted the necessity and relevance to determine the immune responses locally where HPV 16-induced lesions develop. Whether a mucosal route of immunization is better to treat/regress genital infections/tumors than parenteral immunization is still debated. Our data shows that although similar E7-specific IFN-γ secreting CD8 Τ cells responses were measured in the GM upon mucosal routes of E7 vaccine delivery (nasal and vaginal immunizations), only the s.c immunization was able to regress at least all genital tumors in mice. To further increase the vaccine-specific responses in the GM, immunostimulatory agents were i.vag administrated after vaccination. We demonstrated that a single i.vag application of toll like receptor (TLR) agonists after a s.c. E7 vaccination induced a significant increase of E7-specific IFN-γ secreting CD8 Τ cells in the GM. More precisely, regarding CpG and Poly l:C, the effect is most probably associated with a local attraction of total CD8 Τ cells and secondly depends on TLR9 and TLR3/Mda5 signaling pathways, respectively. Finally, this combinatorial strategy induced tumor regression in mice harboring large genital tumors, suggesting that such an immunotherapy could be adequate to treat HPV-induced lesions in women.
Resumo:
Purpose/Objective(s): To implement a carotid dose sparing protocol using helical Tomotherapy in T1N0 squamous cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47 - 74 years. Staging included endoscopic examination, CT-scan and MRI when indicated. Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotid sparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to be covered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV. Doses to the carotid arteries, to the critical organs, and to the planned target volume (PTV) with our standard laryngeal irradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, the Planned Adaptive software (TomoTherapy Inc., Madison, WI) was used to evaluatethe need for a re-planning, which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and data normalization and dose-volume histogram (DVH) interpolation were realized using the Igor Pro software (Portland, OR).Results:A significant (p\0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard deviation [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved. In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point dose to the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose for all patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of 75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effects resolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4 - 5 months post treatment follow-up.Conclusions: Helical Tomotherapy allows a clinically significant decrease of carotid irradiation dose compared to standard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security margins especially when working with high dose gradients. Further investigations and follow-up are underway to better evaluate the late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potential impact on cerebrovascular events.
Resumo:
Purpose/Objective: Phenotypic and functional T cell properties are usually analyzed at the level of defined cell populations. However, large differences between individual T cells may have important functional consequences. To answer this issue, we performed highly sensitive single-cell gene expression profiling, which allows the direct ex vivo characterization of individual virus- and tumor-specific T cells from healthy donors and melanoma patients. Materials and methods: HLA-A*0201-positive patients with stage III/ IV metastatic melanoma were included in a phase I clinical trial (LUD- 00-018). Patients received monthly low-dose of the Melan-AMART- 1 26_35 unmodified natural (EAAGIGILTV) or the analog A27L (ELAGIGILTV) peptides, mixed CPG and IFA. Individual effector memory CD28+ (EM28+) and EM28- tetramer-specific CD8pos T cells were sorted by flow cytometer. Following direct cell lysis and reverse transcription, the resulting cDNA was precipitated and globally amplified. Semi-quantitative PCR was used for gene expression and TCR BV repertoire analyses. Results: We have previously shown that vaccination with the natural Melan-A peptide induced T cells with superior effector functions as compared to the analog peptide optimized for enhanced HLA binding. Here we found that natural peptide vaccination induced EM28+ T cells with frequent co-expression of both memory/homing-associated genes (CD27, IL7R, EOMES, CXCR3 and CCR5) and effector-related genes (IFNG, KLRD1, PRF1 and GZMB), comparable to protective EBV- and CMV-specific T cells. In contrast, memory/homing- and effectorassociated genes were less frequently co-expressed after vaccination with the analog peptide. Conclusions: These findings reveal a previously unknown level of gene expression diversity among vaccine- and virus-specific T cells with the simultaneous co-expression of multiple memory/homing- and effector- related genes by the same cell. Such broad functional gene expression signatures within antigen-specific T cells may be critical for mounting efficient responses to pathogens or tumors. In summary, direct ex vivo high-resolution molecular characterization of individual T cells provides key insights into the processes shaping the functional properties of tumor- and virus-specific T cells.
Resumo:
High-dose cefepime therapy is recommended for febrile neutropenia. Safety issues have been raised in a recent meta-analysis reporting an increased risk of mortality during cefepime therapy. Cefepime-related neurological toxicity has been associated with overdosing due to severe renal dysfunction. This study aimed to investigate the association between cefepime plasma concentrations and neurological toxicity in febrile neutropenic patients. Cefepime trough concentrations (by high-performance liquid chromatography) were retrospectively analyzed for 30 adult febrile neutropenic patients receiving the recommended high-dose regimen (6 g/day for a glomerular filtration rate [GFR] of >50 ml/min). The dose adjustment to renal function was evaluated by the ratio of the cefepime daily dose per 100 ml/min of glomerular filtration. The association between cefepime plasma concentrations and neurological toxicity was assessed on the basis of consistent neurological symptoms and/or signs (by NCI criteria). The median cefepime concentration was 8.7 mg/liter (range, 2.1 to 38 mg/liter) at a median of 4 days (range, 2 to 15 days) after the start of therapy. Neurological toxicity (altered mental status, hallucinations, or myoclonia) was attributed to cefepime in 6/30 (20%) patients (median GFR, 45 ml/min; range, 41 to 65 ml/min) receiving a median dose of 13.2 g/day per 100 ml/min GFR (range, 9.2 to 14.3 g/day per 100 ml/min GFR). Cefepime discontinuation resulted in complete neurological recovery for five patients and improvement for one patient. A multivariate logistic regression model confirmed high cefepime concentrations as an independent predictor of neurological toxicity, with a 50% probability threshold at ≥22 mg/liter (P = 0.05). High cefepime plasma concentrations are associated with neurological toxicity in febrile neutropenic patients with mild renal dysfunction. Careful adherence to normalized dosing per 100 ml/min GFR is crucial. Monitoring of plasma concentrations may contribute to preventing neurological toxicity of high-dose therapy for this life-threatening condition.
Resumo:
A new strategy for the rapid identification of new malaria antigens based on protein structural motifs was previously described. We identified and evaluated the malaria vaccine potential of fragments of several malaria antigens containing α-helical coiled coil protein motifs. By taking advantage of the relatively short size of these structural fragments, we constructed different poly-epitopes in which 3 or 4 of these segments were joined together via a non-immunogenic linker. Only peptides that are targets of human antibodies with anti-parasite in vitro biological activities were incorporated. One of the constructs, P181, was well recognized by sera and peripheral blood mononuclear cells (PBMC) of adults living in malaria-endemic areas. Affinity purified antigen-specific human antibodies and sera from P181-immunized mice recognised native proteins on malaria-infected erythrocytes in both immunofluorescence and western blot assays. In addition, specific antibodies inhibited parasite development in an antibody dependent cellular inhibition (ADCI) assay. Naturally induced antigen-specific human antibodies were at high titers and associated with clinical protection from malaria in longitudinal follow-up studies in Senegal.
Resumo:
PURPOSE: Vaccines targeting tumor associated antigens are in development for bladder cancer. Most of these cancers are nonmuscle invasive at diagnosis and confined in the mucosa and submucosa. However, to our knowledge how vaccination may induce the regression of tumors at such mucosal sites has not been examined previously. We compared different immunization routes for the ability to induce vaccine specific antitumor CD8 T cells in the bladder and bladder tumor regression in mice. MATERIALS AND METHODS: In the absence of a murine bladder tumor model expressing a tumor antigen relevant for human use we established an orthotopic model expressing the HPV-16 tumor antigen E7 as a model. We used an adjuvant E7 polypeptide to induce CD8 T cell mediated tumor regression. RESULTS: Subcutaneous and intravaginal but not intranasal vaccination induced a high number of TetE7(+)CD8(+) T cells in the bladder as well as bladder tumor regression. The entry of vaccine specific T cells in the bladder was not the only key since persistent regression of established bladder tumors by intravaginal or subcutaneous immunization was associated with tumor infiltration of total CD4 and CD8 T cells. This resulted in an increase in TetE7(+)CD8(+) T cells and a decrease in T regulatory cells, leading to an increased number of effector interferon-γ secreting vaccine specific CD8 T cells in the regressing bladder tumor. CONCLUSIONS: These data show that immunization routes should be tailored to each mucosal tumor site. Subcutaneous or intravaginal vaccination may be of additional value to treat patients with bladder cancer.
Resumo:
Endocarditis prophylaxis following genitourinary or gastrointestinal procedures targets Enterococcus faecalis. Prophylaxis recommendations advocate oral amoxicillin (2 g in the United States and 3 g in the United Kingdom) in moderate-risk patients and intravenous amoxicillin (2 g) or vancomycin (1 g) plus gentamicin in high-risk patients. While ampicillin-resistant (or amoxicillin-resistant) E. faecalis is still rare, there is a concern that these regimens might fail against vancomycin-resistant and/or aminoglycoside-resistant isolates. The present study tested oral linezolid as an alternative. Rats with catheter-induced aortic vegetations were given prophylaxis simulating human pharmacokinetics of oral amoxicillin (2- to 3-g single dose), oral linezolid (600 mg, single or multiple oral doses every 12 h), or intravenous vancomycin (1-g single dose). Rats were then inoculated with the minimum inoculum infecting 90% of the animals (90% infective dose [ID(90)]) or with 10 times the ID(90) of the vancomycin-susceptible E. faecalis strain JH2-2 or the vancomycin-resistant (VanA phenotype) E. faecalis strain UCN41. Amoxicillin was also tested with two additional vancomycin-susceptible E. faecalis strains, 309 and 1209. Animals were sacrificed 3 days later. All the tested bacteria were susceptible to amoxicillin and gentamicin. Single-dose amoxicillin provided 100% protection against all four isolates at both the ID(90) and 10 times the ID(90). In contrast, linezolid required up to four consecutive doses to provide full protection against the vancomycin-resistant isolate. Vancomycin protected only against the vancomycin-susceptible strain. The high efficacy of single-dose oral amoxicillin suggests that this regimen could be used for prophylaxis in both moderate-risk and high-risk patients without additional aminoglycosides. Linezolid appears to be less reliable, at least against the vancomycin-resistant strain.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.
Resumo:
OBJECTIVES: To examine whether the humoural response to malaria vaccine candidate antigens, Plasmodium falciparum [circumsporozoite repetitive sequence (NANP)(5) GLURP fragments (R0 and R2) and MSP3] varies with the level of malaria transmission and to determine whether the antibodies (IgG) present at the beginning of the malaria transmission season protect against clinical malaria. METHODS: Cross-sectional surveys were conducted to measure antibody response before, at the peak and at the end of the transmission season in children aged 6 months to 10 years in two villages with different levels of malaria transmission. A cohort study was performed to estimate the incidence of clinical malaria. RESULTS: Antibodies to these antigens showed different seasonal patterns. IgG concentrations to any of the four antigens were higher in the village with high entomological inoculation rate. Multivariate analysis of combined data from the two villages indicated that children who were classified as responders to the selected antigens were at lower risk of clinical malaria than children classified as non-responders [(NANP)(5) (incidence rate ratio (IRR) = 0.65, 95% CI: 0.46-0.92; P = 0.016), R0 (IRR = 0.69, 95% CI: 0.48-0.97; P = 0.032), R2 (IRR = 0.73, 95% CI: 0.50-1.06; P = 0.09), MSP3 (IRR = 0.52, 95% CI: 0.32-0.85; P = 0.009)]. Fitting a model with all four antibody responses showed that MSP3 looked the best malaria vaccine candidate (IRR = 0.63; 95% CI: 0.38-1.05; P = 0.08). CONCLUSION: Antibody levels to the four antigens are affected by the intensity of malaria transmission and associated with protection against clinical malaria. It is worthwhile investing in the development of these antigens as potential malaria vaccine candidates.
Resumo:
BACKGROUND: The dose intensity of chemotherapy can be increased to the highest possible level by early administration of multiple and sequential high-dose cycles supported by transfusion with peripheral blood progenitor cells (PBPCs). A randomized trial was performed to test the impact of such dose intensification on the long-term survival of patients with small cell lung cancer (SCLC). METHODS: Patients who had limited or extensive SCLC with no more than two metastatic sites were randomly assigned to high-dose (High, n = 69) or standard-dose (Std, n = 71) chemotherapy with ifosfamide, carboplatin, and etoposide (ICE). High-ICE cycles were supported by transfusion with PBPCs that were collected after two cycles of treatment with epidoxorubicin at 150 mg/m(2), paclitaxel at 175 mg/m(2), and filgrastim. The primary outcome was 3-year survival. Comparisons between response rates and toxic effects within subgroups (limited or extensive disease, liver metastases or no liver metastases, Eastern Cooperative Oncology Group performance status of 0 or 1, normal or abnormal lactate dehydrogenase levels) were also performed. RESULTS: Median relative dose intensity in the High-ICE arm was 293% (range = 174%-392%) of that in the Std-ICE arm. The 3-year survival rates were 18% (95% confidence interval [CI] = 10% to 29%) and 19% (95% CI = 11% to 30%) in the High-ICE and Std-ICE arms, respectively. No differences were observed between the High-ICE and Std-ICE arms in overall response (n = 54 [78%, 95% CI = 67% to 87%] and n = 48 [68%, 95% CI = 55% to 78%], respectively) or complete response (n = 27 [39%, 95% CI = 28% to 52%] and n = 24 [34%, 95% CI = 23% to 46%], respectively). Subgroup analyses showed no benefit for any outcome from High-ICE treatment. Hematologic toxicity was substantial in the Std-ICE arm (grade > or = 3 neutropenia, n = 49 [70%]; anemia, n = 17 [25%]; thrombopenia, n = 17 [25%]), and three patients (4%) died from toxicity. High-ICE treatment was predictably associated with severe myelosuppression, and five patients (8%) died from toxicity. CONCLUSIONS: The long-term outcome of SCLC was not improved by raising the dose intensity of ICE chemotherapy by threefold.