966 resultados para heterotrophic plate count
Resumo:
Vortex shedding phenomenon produced by a square cylinder placed close to a smooth flat plate is experimentally studied by means of flow visualization techniques and hot-film anemometry. Qualitative and quantitative information about the flow field has been obtained for Reynolds numbers up to 1,000. Vortex shedding images in several Reynolds number have been captured and the non dimensional vortex shedding frequency has been obtained as a function of the Reynolds number.
Resumo:
Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose: The objective of this article is to describe a method to construct an intraoralacrylic device that permits a reline material to be added to the inner surface of thepalatal plate.Materials and Methods: Fifteen 60-day-old adult female rats (Rattus NorvegicusAlbinus Wistar), weighing 150 to 250 g were used for this study and allocated to threegroups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate(Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resinpalatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3,animals maintained under the same conditions as the experimental groups, withoutwearing palatal plates for 14 days. The manipulation of the animals followed theguidelines of the Brazilian College of Animal Experimentation, under the approval ofthe animal ethics committee of the State University of Ponta Grossa. The palatal platescovered the whole palate, were fixed in the molar region with light-cured resin, andwere kept there for 14 days. The animals received a paste diet and water ad libitum.Before and after the trial period, the rats were weighed individually on a precisionscale. Statistical analysis was performed using a two-way analysis of variance (α =0.05) test for comparison of the animals’ weight (g) at time 0 and after 14 days ofusing the palatal plate.Results: No statistical differences were observed regarding the weight of the animalsamong the experimental groups in the study.Conclusions: The individual master impressions, the molar teeth coverage, and themethod of cementation with nonadhesive composite resin provided good stability forthe palatal plate showed in this study, not disturbing the eating habits and nutritionof the animals. This model seems reproducible, offering adequate histopathologicalevaluation. Differences in tissue morphology exist between the animals that used thepalatal plate and the animals that did not use this device. Use of these palatal platescould clarify how prostheses bring changes in the palatal mucosa of users.
Resumo:
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
ObjectiveThe aim of this clinical report was to reestablish the buccal bone wall after immediate implant placement. The socket defect was corrected with autogenous bone, and a connective tissue graft was removed from the maxillary tuberosity to increase the thickness, height, and width of the buccal bone and gingival tissue followed by immediate provisionalization of the crown during the same operation.Clinical ConsiderationsA 66-year-old patient presented with a hopeless maxillary left central incisor with loss of the buccal bone wall. Atraumatic, flapless extraction was performed, and an immediate implant was placed in the extraction socket followed by preparation of an immediate provisional restoration. Subsequently, immediate reconstruction of the buccal bone plate was performed, using the tuberosity as the donor site, to obtain block bone and connective tissue grafts, as well as particulate bone. Finally, immediate provisionalization of the crown followed by simple sutures was performed. Cone-beam computed tomography and periapical radiographs were taken before and after surgery. After 4 months, the final prosthetic crown was made. After a 2-year follow-up, a satisfactory aesthetic result was achieved with lower treatment time and morbidity.ConclusionThis case demonstrates the effective use of immediate reconstruction of the buccal bone wall for the treatment of a hopeless tooth in the maxillary aesthetic area. This procedure efficiently promoted harmonious gingival and bone architecture, recovered lost anatomical structures with sufficient width and thickness, and maintained the stability of the alveolar bone crest in a single procedure.Clinical SignificanceIf appropriate clinical conditions exist, immediate dentoalveolar restoration may be the most conservative means of reconstructing the buccal bone wall after immediate implant placement followed by immediate provisionalization with predictable healing and lower treatment time.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We know the importance of treating water for human consumption because changes in the physicochemical and / or biological has been associated with various health problems, the quality of water intended for human consumption must meet potability standards established by governmental decree 518/2004. The aim of this study was to evaluate the quality of water supplied schools and daycare in the city of São Carlos - SP. We selected 31 schools and kindergartens, and at intervals of 3 months, two water samples taken at three different points - network, tank and fi lter - totaling 186 samples, with an interval of three months, to verify possible differences in sampling points and at different times. The samples were evaluated for the following parameters: presence of total coliform and fecal coliform / E. coli count of heterotrophic bacteria, determination of pH, fl uoride, free residual chlorine, turbidity and color. The largest number of samples outside the standard for coliform was coming from the fi lters and the network, heterotrophic bacteria in most samples was taken out of standard fi lters. In the physical-chemical analysis of samples as many non-standard pH occurred in the network, network, and fl uoride in the fi lter pair in the fi lter to free chlorine and turbidity in the reservoir. The parameter with a larger sample size was inadequate fl uoride. We need more attention to the conservation, cleaning and maintenance of building reservoirs and fi lters in schools and kindergartens of San Carlos, since the water was considered unfi t for consumption.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Environmental data are spatial, temporal, and often come with many zeros. In this paper, we included space–time random effects in zero-inflated Poisson (ZIP) and ‘hurdle’ models to investigate haulout patterns of harbor seals on glacial ice. The data consisted of counts, for 18 dates on a lattice grid of samples, of harbor seals hauled out on glacial ice in Disenchantment Bay, near Yakutat, Alaska. A hurdle model is similar to a ZIP model except it does not mix zeros from the binary and count processes. Both models can be used for zero-inflated data, and we compared space–time ZIP and hurdle models in a Bayesian hierarchical model. Space–time ZIP and hurdle models were constructed by using spatial conditional autoregressive (CAR) models and temporal first-order autoregressive (AR(1)) models as random effects in ZIP and hurdle regression models. We created maps of smoothed predictions for harbor seal counts based on ice density, other covariates, and spatio-temporal random effects. For both models predictions around the edges appeared to be positively biased. The linex loss function is an asymmetric loss function that penalizes overprediction more than underprediction, and we used it to correct for prediction bias to get the best map for space–time ZIP and hurdle models.
Resumo:
The folded plate girder, a newly proposed bridge girder, is investigated through this thesis. The folded plate girder is cold bent out of a single sheet of steel. The cold bending eliminates the costly and inconsistent shop welds found in traditional girders. The folded plate girder is meant for application in short span bridges. The girder was subjected to an equivalent 75 year lifetime loading to investigate the fatigue performance. The rebar detail used in the closure region between adjacent slabs has been investigated in the past by the NCHRP 12-68 project. This thesis will proposes a hooked rebar detail as a cost effective alternative to the previously recommended headed rebar detail. The proposed hooked rebar detail looks to improve upon the headed bar detail by increasing the clear cover, and reducing the cost of fabrication and shipment of the rebar. Six specimens containing closure regions are subjected to both positive and negative moment loading in order to investigate their behavior and failure modes under ultimate load.
Resumo:
A new steel girder bridge system was developed at the University of Nebraska. The innovative girder design is a box girder folded from a single steel plate that has a trapezoid shape with an opening on the bottom. The girder has application in short span bridges and accelerated construction situations. The structural performance of the girder requires investigation in all stages of a bridge’s lifecycle. This thesis contains descriptions and results from the first two tests from a series of tests developed to evaluate this new girder shape. The objective of these two tests was to investigate the constructability of the girders. During construction a bridge is in its least stable condition and it is important that the bridge components exhibit both adequate strength and stability during this critical stage. To this end, two girders were tested in flexure over a simple span as a non-composite beam simulating the loading the girders would be subjected to during construction. The results of the two tests indicate that the folded girder as a whole, and its components, provide adequate strength and stability at construction load levels. Failure occurred at loads that were above normal construction load levels and resulted in a ductile failure mode, which is a well documented benefit of steel components. The girders remained stable through all phases of loading including failure. The top flange was the weakest component of the beam during construction due to its role as a compression element that has a slender and un-braced form. The compression in the top flange caused local buckling in the top flange even at elastic load levels. This was the cause for loss of stiffness and failure in both specimens. Incorporation of a ridge at the center of the top flange of specimens, results of which are not reported in this thesis, proved to resolve this very early buckling issue.
Resumo:
The purpose of this prospective study was to verify the changes in the preoperative and postoperative complete blood counts of patients with surgically treated facial fractures. Fifty consecutive patients with a mean age of 34 years who presented facial fractures and underwent surgical treatment were included. A complete blood count was performed, comprising the red and white blood cell count (cells/mu L), hemoglobin (g/dL), and hematocrit (%) levels. These data were obtained preoperatively and postoperatively during a 6-week period. Statistical analyses were performed using the Kruskal-Wallis and Mann-Whitney tests to identify the possible differences among the groups and among the periods of observation using the Friedman and Wilcoxon matched-pairs signed-ranks tests. The most common location of the fractures was the mandible (42.3%), followed by the zygomatic-orbital (36.5%) and associated locations (21.2%). Leukocytosis was associated with neutrophilia in the immediate postoperative period in all of the groups. There were no values below the reference limits of the values of hemoglobin, hematocrit, and erythrocytes, and no values above the reference limits for the remaining white blood cells, although significant differences among periods were observed in most cells, depending on the type of fracture. The primary findings were leukocytosis associated with neutrophilia, verified in the immediate postoperative period in all of the groups, and the influence of the type of fracture on the significant alterations observed among studied periods on the values of hemoglobin, hematocrit, erythrocytes, leukocytes, neutrophils, and lymphocytes.