984 resultados para graded-index fiber lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fruta-pão é um fruto rico em vitaminas e minerais do qual pode ser extraído o amido ou processado à forma de farinha aumentando sua vida de prateleira. Essa farinha pode substituir parcialmente a farinha de trigo em produtos panificáveis. O objetivo do presente estudo foi extrair e analisar algumas características físicas, químicas e tecnológicas do amido nativo de fruta-pão, além de realizar a caracterização físico-química da farinha obtida desse fruto, de suas misturas com a farinha de trigo e verificar a viabilidade destas na elaboração de pão de forma. O amido de fruta-pão foi submetido às análises de umidade, capacidade de ligação de água a frio (CLAF), poder de inchamento (PI), índice de solubilidade (IS), sinérese, microscopia eletrônica de varredura (MEV) e difração de raio X. O amido de milho foi analisado para efeito de comparação. O amido de fruta-pão apresentou maior umidade (18,32%), CLAF (80,33%), PI (198,71 g/g a 90 0C), IS (7,22% a 90 0C) e sinérese (2,69 mL) quando comparado com o amido de milho. Pela análise de MEV, verificou-se que o amido de fruta-pão apresentou grânulos menores que os do amido de milho, mas ambos com formato poliédrico. A difração de raio X permitiu classificar o amido de milho como tipo A e o de fruta-pão como tipo B. As amostras de farinha analisadas continham um percentual de farinha de fruta-pão de 0% (controle), 5%, 10%, 15%, 20% e 100% e foram submetidas às análises de umidade, cinzas, extrato etéreo, carboidratos, proteína, energia, fibra total, solúvel e insolúvel, pH, cor e granulometria. Os mesmos percentuais de substituição foram utilizados para a elaboração dos pães, analisados em relação a umidade, peso, volume, volume específico, altura, perfil de textura, aceitação sensorial e intenção de compra. A substituição da farinha de trigo pela farinha de fruta-pão influenciou na granulometria das misturas, reduziu o teor de proteína de 10,8% para 3,99%, elevou o percentual de carboidratos, cinzas e pH de 73,84%, 0,52% e 5,94 para 83,10%, 2,19% e 6,34 , respectivamente. No entanto, para a umidade, teor de lipídeos e diferença global de cor das amostras não foi verificada influência significativa do percentual de substituição. A farinha de fruta-pão apresentou um maior percentual de fibras totais (21,17%), solúveis (10,39%) e insolúveis (10,77%). Para os pães de forma, o aumento da substituição não influenciou na umidade e no peso dos pães, exceto para a amostra com 100% de farinha de fruta-pão, que apresentou 41,28% de umidade e peso de 588,65 g. Para as demais análises, os maiores percentuais de substituição influenciaram negativamente as características do produto. Em relação a caracterização físico-química das amostras de farinha, o aumento do percentual de substituição influenciou na maioria dos parâmetros avaliados. Para os pães, as formulações com maiores notas hedônicas e com melhor intenção de compra foram as com substituição de 5% e de 10%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Dynamic Gait Index (DGI) é um teste que avalia o equilíbrio e marcha do corpo humano. OBJETIVOS: Os objetivos deste estudo foram adaptar culturalmente o DGI para o português e avaliar a sua confiabilidade. MATERIAL E MÉTODO: Seguiu-se o método de Guillemin et al. (1993) para a adaptação cultural do instrumento. Trata-se de estudo prospectivo em que 46 pacientes foram avaliados na fase de adaptação cultural e os itens que apresentaram 20% ou mais de incompreensão foram reformulados e reaplicados. A versão final do DGI em português foi aplicada em 35 idosos para examinar a confiabilidade intra e inter-observadores. O coeficiente de Spearman foi utilizado para correlacionar os escores inter e intra-observador e o teste de Wilcoxon para comparar as pontuações. A consistência interna foi analisada pelo coeficiente alfa de Cronbach. RESULTADOS: Houve correlações estatisticamente significantes entre os escores obtidos às avaliações inter e intra-observadores para todos os itens (p<0,001), classificadas como boa a muito forte (com de variação de r=0,655 a r=0,951). O DGI mostrou alta consistência interna entre seus itens nas avaliações inter e intra-observadores (variação de µ ou = 0,820 a a=0,894). CONCLUSÃO: O DGI foi adaptado culturalmente para o português brasileiro, mostrando-se um instrumento confiável.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(vinylidene fluoride-trifluoethylene) electrospun membranes were obtained from a blend of dimethylformamide (DMF) and methylethylketone (MEK) solvents. The inclusion of the MEK to the solvent system promotes a faster solvent evaporation allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. Several processing parameters were systematically changed to study their influence on fiber dimensions. Applied voltage and inner needle diameter do not have large influence on the electrospun fiber average diameter but in the fiber diameter distribution. On the other hand, the increase of the distance between the needle tip to collector results in fibers with larger average diameter. Independently on the processing conditions, all mats are produced in the electroactive phase of the polymer. Further, MC-3T3-E1cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(hydroxybutyrate) (PHB) obtained from sugar cane was dissolved in a blend of chloroform and dimethylformamide (DMF) and electrospun at 40 ºC. By adding DMF to the solution, the electrospinning process for the PHB polymer becomes more stable, allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. The influence of processing parameters on fiber size and distribution was systematically studied. It was observed that an increase of tip inner diameter promotes a decrease of the fiber average size and a broader distribution. On the other hand, an increase of the electric field and flow rate produces an increase of fiber diameter until a maximum of ~2.0 m, but for electric fields higher than 1.5 kV.cm-1, a decrease of the fiber diameter was observed. Polymer crystalline phase seems to be independent of the processing conditions and a crystallinity degree of 53 % was found. Moreover, thermal degradation of the as-spun membrane occurs in single step degradation with activation energy of 91 kJ/mol. Furthermore, MC-3T3-E1 cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combined use of precision agriculture and the Diagnosis and Recommendation Integrated System (DRIS) allows the spatial monitoring of coffee nutrient balance to provide more balanced and cost-effective fertilizer recommendations. The objective of this work was to evaluate the spatial variability in the nutritional status of two coffee varieties using the Mean Nutritional Balance Index (NBIm) and its relationship with their respective yields. The experiment was conducted in eastern Minas Gerais in two areas, one planted with variety Catucaí and another with variety Catuaí. The NBIm of the two varieties and their yields were analyzed through geostatistics and, based on the models and parameters of the variograms, were interpolated to obtain their spatial distribution in the studied areas. Variety Catucai, with grater spatial variability, was more nutritional unbalanced than variety Catuai, and consequently produced lower yields. Excess of Fe and Mn makes these elements limiting yield factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein-based polymers are present in a wide variety of organisms fulfilling structural and mechanical roles. Advances in protein engineering and recombinant DNA technology allow the design and production of recombinant protein-based polymers (rPBPs) with an absolute control of its composition. Although the application of recombinant proteins as biomaterials is still an emerging technology, the possibilities are limitless and far superior to natural or synthetic materials, as the complexity of the structural design can be fully customized. In this work, we report the electrospinning of two new genetically engineered silk-elastin-like proteins (SELPs) consisting of alternate silk- and elastin-like blocks. Electrospinning was performed with formic acid and aqueous solutions at different concentrations without addition of further agents. The size and morphology of the electrospun structures was characterized by scanning electron microscopy showing to be dependent of concentration and solvent used. Treatment with air saturated with methanol was employed to stabilize the structure and promote water insolubility through a time-dependent conversion of random coils into β-sheets (FTIR). The resultant methanol-treated electrospun mats were characterized for swelling degree (570-720%), water vapour transmission rate (1083 g/m2/day) and mechanical properties (modulus of elasticity of ~126 MPa). Furthermore, the methanol-treated SELP fiber mats showed no cytotoxicity and were able to support adhesion and proliferation of normal human skin fibroblasts. Adhesion was characterized by a filopodia-mediated mechanism. These results demonstrate that SELP fiber mats can provide promising solutions for the development of novel biomaterials suitable for tissue engineering applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Battery separators based on electrospun membranes of poly(vinylidene fluoride) (PVDF) have been prepared in order to study the effect of fiber alignment on the performance and characteristics of the membrane. The prepared membranes show an average fiber diameter of 272 nm and a degree of porosity of 87 %. The gel polymer electrolytes are prepared by soaking the membranes in the electrolyte solution. The alignment of the fibers improves the mechanical properties for the electrospun membranes. Further, the microstructure of the membrane also plays an important role in the ionic conductivity, being higher for the random electrospun membrane due to the lower tortuosity value. Independently of the microstructure, both membranes show good electrochemical stability up to 5.0 V versus Li/Li+. These results show that electrospun membranes based on PVDF are appropriate for battery separators in lithium-ion battery applications, the random membranes showing a better overall performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber meshes of poly(hydroxybutyrate) (PHB) and poly(hydroxybutyrate)/ poly(ethylene oxide) (PHB/PEO) with different concentrations of chlorhexidine (CHX) were prepared by electrospinning, for assessment as a polymer based drug delivery system. The electrospun fibers were characterized at morphological, molecular and mechanical levels. The bactericidal potential of PHB and PHB/PEO electrospun fibers with and without CHX was investigated against Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) by disk diffusion susceptibility tests. Electrospun fibers containing CHX exhibited bactericidal activity. PHB/PEO-1%CHX displayed higher CHX release levels and equivalent antibacterial activity when compared to PHB/PEO with 5 and 10 wt% CHX. Bactericidal performance of samples with 1 wt% CHX was assessed by Colony Forming Units (CFU), where a reduction of 100 % and 99.69 % against E. coli and S. aureus were achieved, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Battery separators based on electrospun membranes of poly(vinylidene fluoride) (PVDF) have been prepared in order to study the effect of fiber alignment on the performance and characteristics of the membrane. The prepared membranes show an average fiber diameter of ~272 nm and a degree of porosity of ~87 %. The gel polymer electrolytes are prepared by soaking the membranes in the electrolyte solution. The alignment of the fibers improves the mechanical properties for the electrospun membranes. Further, the microstructure of the membrane also plays an important role in the ionic conductivity, being higher for the random electrospun membrane due to the lower tortuosity value. Independently of the microstructure, both membranes show good electrochemical stability up to 5.0 V versus Li/Li+. These results show that electrospun membranes based on PVDF are appropriate for battery separators in lithium-ion battery applications, the random membranes showing a better overall performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the effect of growth reducer and nitrogen fertilization on morphological variables, SPAD index, radiation interception, and grain yield of three cultivars of wheat. The experimental design was a randomized block in factorial scheme 3x5x2, with three cultivars (Mestre, Iguaçú and Itaipú), five nitrogen doses (0, 40, 80, 120, 160 Kg ha-1), and application or no application of a growth reducer, with three replications. The following characteristics were evaluated: plant height, SPAD index, leaf area index (LAI), Global Radiation Interception (GRI) and grain yield. The Tukey test (p < 0.05) was used for the comparison between the means of cultivar and growth reducer factors, and for a regression analysis to evaluate N levels. Increasing the dose of nitrogen promotes an increase in LAI of plants of wheat crops differently among cultivars, which leads to a greater degree of global radiation interception. At doses higher or equal to 120 Kg ha-1 of nitrogen, there are significant differences in grain yield between treatments with and without the application of the growth reducer. The significant interaction between growth reducer and nitrogen dose, showed that applications of growth reducer increase the GRI at doses above and below 80 Kg ha-1 of nitrogen. Nitrogen rates of 138 and 109 Kg ha-1 are responsible for maximum grain yields of wheat, which is 4235 and 3787 Kg ha-1 with and without the use of growth reducer, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exposure index (lgM) obtained from a radiographic image may be a useful feedback indicator to the radiographer about the appropriate exposure level in routine clinical practice. This study aims to evaluate lgM in orthopaedic radiography performed in the standard clinical environment. We analysed the lgM of 267 exposures performed with an AGFA CR system. The mean value of lgM in our sample is 2.14. A significant difference (P=0.000<0.05) from 1.96 lgM reference is shown. Data show that 72% of exposures are above the 1.96 lgM and 42% are above the limit of 2.26. Median values of lgM are above 1.96 and below 2.26 for Speed class (SC) 200 (2.16) and SC400 (2.13). The interquartile range is lower in SC400 than in SC200. Data seem to indicate that lgM values are above the manufacturer’s reference of 1.96. Departmental exposure charts should be optimised to reduce the dose given to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar o valor preditivo do CRIB (Clinical Risk Index for Babies) para o risco de mortalidade neonatal ao peso de nascimento (PN) e idade gestacional (IG). MÉTODO: Numa coorte prospectiva foram estudados, durante o ano de 1996, 71 recém-nascidos admitidos na unidade de terapia intensiva, com PN < 1.500 g e/ou IG < 31 semanas. RESULTADOS: A taxa de mortalidade foi de 29,6%; para PN < 1.000 g ou IG < 29 semanas foi de 60%, enquanto que para o escore de CRIB > 10 foi de 100%. CONCLUSÕES: O escore de CRIB > 10 correspondeu a maiores especificidade e valor preditivo positivo em relação aos demais parâmetros. A área determinada pela "receiver operating characteristic" relativa ao CRIB também foi superior. O CRIB mostrou-se um marcador mais acurado na previsão de risco de mortalidade quando comparado ao PN ou IG isoladamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we analyze the relationship between volatility in index futures markets and the number of open and closed positions. We observe that, although in general both positions are positively correlated with contemporaneous volatility, in the case of S&P 500, only the number of open positions has influence over the volatility. Additionally, we observe a stronger positive relationship on days characterized by extreme movements of these contracting movements dominating the market. Finally, our findings suggest that day-traders are not associated to an increment of volatility, whereas uninformed traders, both opening and closing their positions, have to do with it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a Markov chain framework to characterize the behavior of the CBOE Volatility Index (VIX index). Two possible regimes are considered: high volatility and low volatility. The specification accounts for deviations from normality and the existence of persistence in the evolution of the VIX index. Since the time evolution of the VIX index seems to indicate that its conditional variance is not constant over time, I consider two different versions of the model. In the first one, the variance of the index is a function of the volatility regime, whereas the second version includes an autoregressive conditional heteroskedasticity (ARCH) specification for the conditional variance of the index.