925 resultados para fragility fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The WHO fracture risk assessment tool FRAX® is a computer based algorithm that provides models for the assessment of fracture probability in men and women. The approach uses easily obtained clinical risk factors (CRFs) to estimate 10-year probability of a major osteoporotic fracture (hip, clinical spine, humerus or wrist fracture) and the 10-year probability of a hip fracture. The estimate can be used alone or with femoral neck bone mineral density (BMD) to enhance fracture risk prediction. FRAX® is the only risk engine which takes into account the hazard of death as well as that of fracture. Probability of fracture is calculated in men and women from age, body mass index, and dichotomized variables that comprise a prior fragility fracture, parental history of hip fracture, current tobacco smoking, ever long-term use of oral glucocorticoids, rheumatoid arthritis, other causes of secondary osteoporosis, daily alcohol consumption of 3 or more units daily. The relationship between risk factors and fracture probability was constructed using information of nine population-based cohorts from around the world. CRFs for fracture had been identified that provided independent information on fracture risk based on a series of meta-analyses. The FRAX® algorithm was validated in 11 independent cohorts with in excess of 1 million patient-years, including the Swiss SEMOF cohort. Since fracture risk varies markedly in different regions of the world, FRAX® models need to be calibrated to those countries where the epidemiology of fracture and death is known. Models are currently available for 31 countries across the world. The Swiss-specific FRAX® model was developed very soon after the first release of FRAX® in 2008 and was published in 2009, using Swiss epidemiological data, integrating fracture risk and death hazard of our country. Two FRAX®-based approaches may be used to explore intervention thresholds. They have recently been investigated in the Swiss setting. In the first approach the guideline that individuals with a fracture probability equal to or exceeding that of women with a prior fragility fracture should be considered for treatment is translated into thresholds using 10-year fracture probabilities. In that case the threshold is age-dependent and increases from 16 % at the age of 60 ys to 40 % at the age of 80 ys. The second approach is a cost-effectiveness approach. Using a FRAX®-based intervention threshold of 15 % for both, women and men 50 years and older, should permit cost-effective access to therapy to patients at high fracture probability in our country and thereby contribute to further reduce the growing burden of osteoporotic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FRAX-based cost-effective intervention thresholds in the Swiss setting were determined. Assuming a willingness to pay at 2× Gross Domestic Product per capita, an intervention aimed at reducing fracture risk in women and men with a 10-year probability for a major osteoporotic fracture at or above 15% is cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a case of a fatal speed flying accident in which the victim was electrocuted, burned and fell from a great height. Post-mortem imaging revealed acute appearing fractures on CT, without bone marrow oedema on MRI. Based on the known clinical imaging findings of bone marrow oedema in acute fractures, we concluded that the speed flyer died from electrocution rather than the fall and that the fractures occurred post-mortem. Radiological imaging augmented the reconstruction of the peri-mortem events. Further research is needed to assess whether bone marrow oedema in acute fractures is a reliable vital sign.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For nonsurgical treatment of fractures of the proximal phalanges of the triphalangeal fingers, different dynamic casts have been described. The main principle behind these casts is advancement and tightening of the extensor hood, caused by a combination of blocking the metacarpophalangeal joints in flexion and actively flexing the proximal interphalangeal joints. In contrast to established treatment protocols using functional forearm casts, the Lucerne cast allows for free mobilization of the wrist joint. The purpose of the current multicenter study was to compare the results of conservative, functional treatment using 2 different methods, either a forearm cast or a Lucerne cast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of our prospective study was to document the clinical and radiological results of conservative-functional treatment of extraarticular proximal phalangeal fractures without immobilisation of the wrist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five 'windows' for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called 'Pararectus' approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (sd 2.6) vs 0.1 mm (sd 0.3), p < 0.001; and mean gap 11.5 mm (sd 6.5) vs 0.8 mm (sd 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A retrospective study was performed on the use of bioabsorbable pins in the fixation of osteochondral fractures (OCFs) after traumatic patellar dislocation in children. Eighteen children (13 females, 5 males) aged 11 to 15 years (mean age 13.1 years) with osteochondral fracture (OCF) of the knee joint were treated at the authors' institution. Followup ranged from 22 months to 5 years. Diagnosis was verified by X-ray and magnetic resonance imaging (MRI) of the knee and patella. In seven patients the osteochondral fragment was detached from the patella and in 11 it was detached from the lateral femoral condyle. All patients were subjected to open reduction and fixation of the lesion with bioabsorbable pins. Postoperatively, the knee was immobilized in a cast and all patients were mobilized applying a standardized protocol. Bone consolidation was successful in 17 of the 18 patients. Bioabsorbable pins reliably fix OCF in children and adolescents, demonstrating a high incidence of consolidation of the detached osteochondral fragment in short- and middle-term followup without requiring further operative procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of the study were (1) to determine the cumulative two to twenty-year survivorship of the hip after open reduction and internal fixation of displaced acetabular fractures, (2) to identify factors predicting conversion to total hip arthroplasty or hip arthrodesis, and (3) to create a predictive model that calculates an individual's probability of early need for total hip arthroplasty or hip arthrodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Falls and fractures in the elderly are among the leading causes of disability. We investigated whether pacemaker implantation prevents falls in patients with SND in a large cohort of patients. Methods. Patient demographics and medical history were collected prospectively. Fall history was retrospectively reconstituted from available medical records. The 10-year probability for major osteoporotic fractures was calculated retrospectively from available medical records using the Swiss fracture risk assessment tool FRAX-Switzerland. Results. During a mean observation period of 2.3 years after implantation, the rates of fallers and injured fallers with fracture were reduced to 15% and 6%, respectively. This corresponds to a relative reduction in the number of fallers of 75% (P < 0.001) and of injured fallers of 63% (P = 0.014) after pacemaker implantation. Similarly, the number of falls was reduced from 60 (48%) before pacemaker implantation to 22 (18%) thereafter (relative reduction 63%, P = 0.035) and the number of falls with injury from 22 (18%) to 7 (6%), which corresponds to a relative reduction of 67%, P = 0.013. Conclusion. In patients with SND, pacemaker implantation significantly reduces the number of patients experiencing falls, the total number of falls, and the risk for osteoporotic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the difference between the effects of a 5-day and a 1-day course of antibiotics on the incidence of postoperative infection after displaced fractures of the orbit. A total of 62 patients with orbital blow-out fractures were randomly assigned to two groups, both of which were given amoxicillin/clavulanic acid 1.2g intravenously every 8h from the time of admission to 24h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625mg orally every 8h for 4 further days. The 1-day group were given placebo orally at the same time intervals. Follow up appointments were 1, 2, 4, 6, and 12 weeks, and 6 months, postoperatively. An infection in the orbital region was the primary end point. Sixty of the 62 patients completed the study. Two of the 29 patients in the 5-day group (6.8%) and 1/31 patients in the 1-day group (3.2%) developed local infections. In the 5-day group 1 patient developed diarrhoea. In the 1-day group 1 patient developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. We conclude that in displaced orbital fractures a postoperative 1-day course of antibiotics is as effective in preventing infective complications as a 5-day regimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to identify the occurrence, type, location, and severity of dental injuries (DIs), as well as predictors for DIs, in pediatric patients with facial fractures.