876 resultados para fault propagation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The soliton propagation in a medium with Kerr nonlinearity and resonant impurities was studied by a variational approach. The existence of a solitary wave was shown within the framework of a combined nonintegrable system composed of one nonlinear Schrödinger and a pair of Bloch equations. The analytical solution which was obtained, was tested through numerical simulations confirming its solitary wave nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Curcuma longa L. is used in many countries for its flavor, and medicinal and cosmetic attributes, as well as for its peculiar starch characteristics. These factors have driven an interest in the in vitro propagation of this species, looking for germplasm bank maintenance, production of disease free plants, genetic variability induction from callus, and as a tool for starch research. However, there are few reports concerning the micropropagation of Curcuma longa. The in vitro propagation rate of this species, cultured under two benzylaminopurine (BAP) concentrations, was the aim of this research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cell culture of Maytenus ilicifolia were established in order to produce and to quantify the antitumoral and antioxidant quinonemethide triterpenes. In vitro calli were induced from leaf explants of native plants and cultured in semi-solid medium under controlled conditions of humidity, temperature and photoperiod. The quinonemethide triterpenes showed maximum accumulation in the logarithmic phase growth of the cell culture. A rapid, sensitive and reliable reverse-phase HPLC method was used for quantitative determination of the antitumoral and antioxidant quinonemethide triterpenes, 22β-hydroxymaytenin and maytenin in callus of Maytenus ilicifolia. Well resolved peaks with good detection response and linearity in the range 1.0 - 100 μg/mL were obtained. This quantitative work was performed by an external standard method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot radial distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vegetative propagation of Dovyalis hebecarpawas studied using herbaceous cuttings of a hybrid introduced in Brazil by the College of Agriculture, Campus of Jaboticabal-UNESP. The treatments consisted of (1) evaluating the effect of five 3-Indolebutyric acid (IBA) doses (0 (control), 1,000, 3,000, 5,000 and 7,000 mg.L -1); (2) the influence of two kinds of herbaceous cuttings (apical and sub-apical) and (3) the collection position on the plant (upper and lower part of the canopy) at two different times of the year (autumn and spring). The experimental design was completely randomized with four replicates of 10 cuttings each; the analysis was on a 5 × 2 × 2 factorial layout. The growth regulator (IBA) did not influence the rooting of cuttings in either sampling season. The best season for the rooting was spring. Apical cuttings were desirable for rooting in both seasons. In autumn cuttings taken from the lower portion of the plant showed significantly higher rooting values than the ones from the upper portion; and in spring cuttings taken from the upper portion had higher rooting percentages. © 2007 by The Haworth Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The numerical model FUNWAVE was adapted in order to simulate the generation and propagation of ship waves to shore, including phenomena such as refraction, diffraction, currents and breaking of waves. Results are shown for Froude numbers equal to 0.8, 1.0 and 1.1, in order to verify the refraction of the wave pattern, identify breaking conditions and to investigate the wave generation scheme as a moving pressure at the free surface. © 2009 World Scientific Publishing Co. Pte. Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection of young poults with turkey coronavirus (TCoV) produces a syndrome characterized by acute enteritis, diarrhea, anorexia, ruffled feathers, decreased body weight gain and uneven flock growth. The objective of this study was to standardize an intestinal organ culture (IOC) in order to assess host-virus interaction related to apoptosis. For this purpose the Brazilian strain (TCoV/Brazil/2006 with GenBank accession number FJ188401), was used for infection. Infected IOC cells had mitochondrial dysfunction and initial nuclear activation with MTT value of 90.7 (± 2.4) and apoptotic factor 2.21 (± 2.1), considered statistically different from uninfected IOC cells (p > 0.05). The kinetics of TCoV antigens and viral RNA was directly correlated to annexin-V, caspases- 2 and -3, p53, BCl-2 antigens at 24, 72 and 96 h post-infection (p.i.). Morphological and biochemical features of apoptosis, such as in situ nuclear fragmentation (TUNEL and annexin-V) and DNA ladder formation were also detected in infected cells at all assayed p.i. intervals. Moreover, different from other coronaviruses, the expression of both effective caspase-2 and - 3 and p53 antigens were considered lower. However, at all p.i., the BCl-2 antigens were expressed quantitatively and qualitatively as viral antigen measured by immunofluorescence microscopy analysis. Because the diagnosis of TCoV infection is only performed by infecting embryonated poult eggs, the pathological characteri tics related to host-virus interaction remain unclear. This is the first report on apoptosis of TCoV infected IOC, and reveals that it may be useful immunological method to assess virus pathogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for spatial electric load forecasting using multi-agent systems, especially suited to simulate the local effect of special loads in distribution systems is presented. The method based on multi-agent systems uses two kinds of agents: reactive and proactive. The reactive agents represent each sub-zone in the service zone, characterizing each one with their corresponding load level, represented in a real number, and their relationships with other sub-zones represented in development probabilities. The proactive agent carry the new load expected to be allocated because of the new special load, this agent distribute the new load in a propagation pattern. The results are presented with maps of future expected load levels in the service zone. The method is tested with data from a mid-size city real distribution system, simulating the effect of a load with attraction and repulsion attributes. The method presents good results and performance. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important alteration of the equivalent loads profile has been observed in the electrical energy distribution systems, for the last years. Such fact is due to the significant increment of the electronic processors of electric energy that, in general, behave as nonlinear loads, generating harmonic distortions in the currents and voltages along the electric network. The effects of these nonlinear loads, even if they are concentrated in specific sections of the network, are present along the branch circuits, affecting the behavior of the entire electric network. For the evaluation of this phenomenon it is necessary the analysis of the harmonic currents flow and the understanding of the causes and effects of the consequent voltage harmonic distortions. The usual tools for calculation the harmonic flow consider one-line equivalent networks, balanced and symmetrical systems. Therefore, they are not tools appropriate for analysis of the operation and the influence/interaction of mitigation elements. In this context, this work proposes the development of a computational tool for the analysis of the three-phase harmonic propagation using Norton modified models and considering the real nature of unbalanced electric systems operation. © 2011 IEEE.