1000 resultados para decisão fazer versus comprar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Evaluate the type of breast compression (gradual or no gradual) that provides less discomfort to the patient. Methods and Materials: The standard projections were simulated [craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast compressions in 90 volunteers women aged between 19 and 86. The women were organised in groups according to the breast density. The intensity of discomfort was evaluated using the scale that have represented several faces (0-10) proposed by Wong Baker in the end of each simulation. It was also applied an interview using focus group to debate the score that were attributed during pain evaluation and to identify the criteria that were considered to do the classification. Results: The women aged between 19-29y (with higher breast density) classified the pain during no gradual compression as 4 and the gradual compression as 2 for both projections. The MLO projection was considered the most uncomfortable. During the focus group interview applied to this group was highlighted that compression did not promoted pain but discomfort. They considered that the high expectations of pain did not correspond to the discomfort that they felt. Similar results were identified for the older women (30-50y; > 50y). Conclusion: The radiographers should considerer the technique for breast compression. The gradual compression was considered for the majority of the women as the most comfortable regardless of breast density. The MLO projection was considered as uncomfortable due to the positioning (axila and inclusion of pectoral muscle) and due to the higher breast compression compared to the CC projection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the advantages and drawbacks of a vector delay/frequency-locked loop (VDFLL) architecture regarding the conventional scalar and the vector delay-locked loop (VDLL) architectures for GNSS receivers in harsh scenarios that include ionospheric scintillation, multipath, and high dynamics motion. The VDFLL is constituted by a bank of code and frequency discriminators feeding a central extended Kaiman filter (EKF) that estimates the receiver's position, velocity, and clock bias. Both code and frequency loops are closed vectorially through the EKF. The VDLL closes the code loop vectorially and the phase loops through individual PLLs while the scalar receiver closes both loops by means of individual independent PLLs and DLLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the cost-effectiveness of treatment regimens with cyclosporine or tacrolimus, five years after renal transplantation.METHODS This cost-effectiveness analysis was based on historical cohort data obtained between 2000 and 2004 and involved 2,022 patients treated with cyclosporine or tacrolimus, matched 1:1 for gender, age, and type and year of transplantation. Graft survival and the direct costs of medical care obtained from the National Health System (SUS) databases were used as outcome results.RESULTS Most of the patients were women, with a mean age of 36.6 years. The most frequent diagnosis of chronic renal failure was glomerulonephritis/nephritis (27.7%). In five years, the tacrolimus group had an average life expectancy gain of 3.96 years at an annual cost of R$78,360.57 compared with the cyclosporine group with a gain of 4.05 years and an annual cost of R$61,350.44.CONCLUSIONS After matching, the study indicated better survival of patients treated with regimens using tacrolimus. However, regimens containing cyclosporine were more cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Bioenergia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-loss power transmission gears operate at lower temperature than conventional ones because their teeth geometry is optimized to reduce friction. The main objective of this work is to compare the operating stabilization temperature and efficiency of low-loss austempered ductile iron (ADI) and carburized steel gears. Three different low-loss tooth geometries were adopted (types 311, 411 and 611, all produced using standard 20° pressure angle tools) and corresponding steel and ADI gears were tested in a FZG machine. The results obtained showed that low-loss geometries had a significant influence on power loss, gears 611 generating lower power loss than gears 311. At low speeds (500 and 1000 rpm) and high torque ADI gears generated lower power loss than steel gears. However, at high speed and high torque (high input power and high stabilization temperature) steel gears had better efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Ciência e Sistemas de Informação Geográfica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Síndrome de Brown (SB) é uma síndrome anatómica e restritiva. Segundo Brown (1942), esta síndrome é classificada como uma ausência de elevação em adução, uma síndrome restritiva do grande oblíquo. Pode ser congénita, adquirida e iatrogénica e divide-se como ligeira, severa ou profunda. O Pequeno Oblíquo (PO) tem como acções a exciclodução, elevação e abdução. Ao estar afectado, observa-se nos movimentos oculares limitação da elevação e adução, que induz uma paralisia deste músculo. Assim, as duas apresentam ausência de elevação em adução, sendo importante, a realização de diagnóstico diferencial entre elas. Objectivos: Identificar as diversas características motoras e sensoriais da paralisia do PO comparando-as com as características da SB, especificando os testes de ortóptica adequados. Apresentar o diagnóstico diferencial a realizar, explicitando as características principais dos exames coordimétricos e do teste das ducções forçadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O CPAP nasal é o tratamento de eleição para os pacientes com Síndrome da Apneia Obstrutiva do Sono (SAOS). Com a máscara nasal podem ocorrer fugas de ar pela boca, que podem por em causa a aderência do paciente ao tratamento devido muitas vezes ao desconforto que provocam, ao aumento do trabalho respiratório e por afectarem a qualidade do sono. Objectivos: Este estudo tem como principal objectivo verificar a eficácia da banda submentoniana e da máscara facial na correcção das fugas pela boca em pacientes com SAOS. Métodos e Participantes: Uma amostra de conveniência de 15 pacientes (8 homens) com SAOS e a fazerem CPAP com máscara nasal, foi recrutada. Foram divididos em dois grupos A e B, onde no grupo A se colocou a banda submentoniana e no grupo B se alterou a interface para máscara facial. Medidas e Resultados: As variáveis avaliadas neste estudo foram as fugas, o IAH, o percentil 95 da pressão de tratamento, a Sa,O2 e os efeitos adversos das duas intervenções. O nível de fugas reduziu no grupo A de 38±11,27 para 24,55±14,30L/min (p=0,002) e no grupo B de 34,34±16,50 para 18,51±16,22L/min (p=0,008). O IAH aumentou no grupo B de 2,60±2,13 para 4,41±3,88 (p=0,016). Relativamente ao percentil 95 da pressão de tratamento aumentou nos dois grupos (Grupo A de 10,15±2,63 para 12,08±2,45cmH2O (p=0,008) e no Grupo B 10,51±1,88 para 12,64±1,29cmH2O (p=0,008)). A Sa,O2 mínima aumentou e o tempo<90% diminui no grupo A com p=0,008, p=0,031, respectivamente. Quanto ao uso auto-reportado verificaram-se poucos efeitos adversos, salientando-se apenas a facilidade de colocação da banda submentoniana, a secura da boca nos dois grupos, a pressão no queixo provocada pela banda e a dor no dorso do nariz provocada pela máscara facial. Conclusão: Ambas as estratégias provaram ser mais eficazes a reduzir a fuga que a máscara nasal. Foram bem toleradas e com poucos efeitos adversos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Gestão e Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologias para obtenção do grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyse the relationship between the privatization of a public firm and government preferences for tax revenue, by considering a (sequential) Stackelberg duopoly with the public firm as the leader. We assume that the government payoff is given by a weighted sum of tax revenue and the sum of consumer and producer surplus. We get that if the government puts a sufficiently larger weight on tax revenue than on the sum of both surpluses, it will not privatize the public firm. In contrast, if the government puts a moderately larger weight on tax revenue than on the sum of both surpluses, it will privatize the public firm. Furthermore, we compare our results with the ones previously published by an other author obtained in a (simultaneous) Cournot duopoly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A delayed evaluation of two groups of patients with paracoccidioidomycosis was carried out. Both groups were treated with amphotericin B, "but one of them was submitted to maintenance treatment with sulfonamides. Statistical analysis showed that treatment is more effective when patients are maintained with sulfonamide drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Sanitária