872 resultados para Validation of test results
Resumo:
It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.
Resumo:
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.
Resumo:
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Resumo:
Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.
Resumo:
Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Background Apathy is a frequent neuropsychiatric condition in neurodegenerative disorders, depression, and often in mild cognitive impairment. The Apathy Inventory (AI) is a reliable instrument for improving the accuracy of the apathy diagnosis. The aim was to establish the validity of the Apathy Inventory for the Brazilian community. Methods We established the concurrent validity, internal consistency, inter-rater reliability, and the sensitivity and specificity of AI for the Brazilian community in a cohort of 175 individuals with Alzheimer's disease, Parkinson's disease, depression, mild cognitive impairment, and healthy controls. The three dimensions of the AI (emotional blunting, lack of initiative, and lack of interest) were compared with the Apathy domain of the Neuropsychiatric Inventory-Clinician rating scale (NPI-C) in an independent scheme. Results The analyses demonstrated high correlation coefficients in AI's individual dimensions and in AI-total score (F = 0.965). Concerning the NPI-C/Apathy domain, intra-class correlation coefficients were also high (F = 0.977). Concurrent validity was high according to both raters on AI dimensions × NPI-C/Apathy domain and regarding total score (rater 1: rho = 0.956 vs. rater 2: rho = 0.970). The internal consistency of the AI was also high concerning the AI's individual dimensions and total score (rater 1: 0.945 vs. rater 2: 0.958). Conclusion We observed high internal consistency, high concurrent validity, and inter-rater reliability of the Apathy Inventory. In addition, we found that its sensitivity and specificity were high. We suggest that the Brazilian version of the Apathy Inventory would be an appropriate instrument to identify the apathy syndrome in Brazilian patients. © 2012 John Wiley & Sons, Ltd.
Resumo:
Includes bibliography.
Resumo:
Objetivo:Este estudo teve como objetivo construir e validar um instrumento de avaliação da compreensão de leitura a fim de caracterizar o perfil de leitura e detectar dificuldades de compreensão em escolares do terceiro ao quinto ano do Ensino Fundamental.Métodos:Participaram 378 escolares divididos em trés grupos para avaliação da compreensão de proposições literais e inferenciais de micro e macroestruturas de dois textos expositivos e dois textos narrativos por meio de questões de múltipla escolha.Resultados:Os dados analisados estatisticamente indicaram valores do teste alfa de Cronbach apresentando consisténcia interna nos quatros textos aplicados para os trés grupos.Conclusão:Foi possível constatar que os escolares apresentaram menor número de erros com o aumento da escolarização e que cada tipo de texto apresentou uma dificuldade específica para os escolares.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objectives To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Method Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. Results A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. Ascites was added in the nursing diagnosis excessive fluid volume. Conclusion The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Implications for Practice Support the assessment of patients with decompensated heart failure. Objetivos Realizar a validacAo consensual das definicoes operacionais dos diagnosticos de enfermagem Intolerancia a atividade, Volume de liquidos excessivo e Debito cardiaco diminuido em pacientes com insuficiencia cardiaca descompensada. Metodo ValidacAo consensual em duas etapas: Analogia de semelhanca das caracteristicas definidoras e desenvolvimento de definicoes operacionais e validacAo com expertst. Resultados Foram encontradas 38 caracteristicas definidoras para os diagnosticos de enfermagem. Suas definicoes operacionais foram desenvolvidas e seu conteudo validado. Os resultados mostram que houve 100% de concordancia entre os sete experts apos cinco rodada. As definicoes operacionais foram classificadas com base no nivel de concordanica. Ascite foi acrescentada ao diagnostico Volume de liquidos excessivo. ConclusAo A validacAo consensual melhora a interpretacAo das respostas humanas, embasando a selecAo de intervencoes de enfermagem e contribuindo para melhorar os resultados. Implicacoes Para A Pratica Apoio a avaliacAo dos pacientes com insuficiencia cardiaca descompensada.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Translation, cross-cultural adaptation and validation of the DYMUS questionnaire for the assessment of dysphagia in multiple sclerosis. The original English version of the DYMUS was translated using the forward-backward technique, cross-culturally adaptated, pilot-tested in 40 patients, and then applied to 100 multiple sclerosis patients to assess the reliability and construct validity. Construct validity was assessed by Mann–Whitney test and Spearman’s correlation coefficient (rs). The internal consistency of the questionnaire was evaluated using Cronbach’s alpha coefficient and inter-item correlation. DYMUS-BR internal consistency was high (Cronbach’s alpha= 0.72); Cronbach’s alpha was 0.65 for the ‘dysphagia for solids’ subscale and 0.67 for the ‘dysphagia for liquids’ subscale and positive inter-item correlations was found between all items, except for weight loss question. Significant association (p<0.001) and correlation (rs = 0,357; p = 0.01) was found between DYMUS-BR and dysphagia self-assessment. The DYMUS-BR questionnaire maintained the characteristics of that originally described, demonstrating to be a reliable, valid, easy and consistent tool to be used by health professionals for preliminary selection of Brazilian MS patients who need more specific instrumental analyses of swallowing.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)