994 resultados para Signal de transduction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a PhD degree in Biochemistry at Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a PhD degree in Biochemistry at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given an hyperspectral image, the determination of the number of endmembers and the subspace where they live without any prior knowledge is crucial to the success of hyperspectral image analysis. This paper introduces a new minimum mean squared error based approach to infer the signal subspace in hyperspectral imagery. The method, termed hyperspectral signal identification by minimum error (HySime), is eigendecomposition based and it does not depend on any tuning parameters. It first estimates the signal and noise correlation matrices and then selects the subset of eigenvalues that best represents the signal subspace in the least squared error sense. The effectiveness of the proposed method is illustrated using simulated data based on U.S.G.S. laboratory spectra and real hyperspectral data collected by the AVIRIS sensor over Cuprite, Nevada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

xi RESUMO A acção da insulina no músculo esquelético depende de um reflexo parassimpático hepático que conduz à libertação de uma substância hepática sensibilizadora da insulina, designada por HISS, responsável por cerca de 55% do efeito hipoglicemiante da insulina. A acção da HISS é finamente regulada pelo monóxido de azoto (NO) hepático e pelo estado prandial, aumentando no período pós-prandial imediato e diminuindo progressivamente com as horas de jejum. A secreção da HISS pode ser inibida cirúrgica ou farmacologicamente, quer por desnervação selectiva do plexo anterior hepático, quer por administração de atropina, quer por inibição do sintase do NO (NOS) hepático. O objectivo geral do trabalho apresentado nesta dissertação foi a caracterização da via de transdução de sinal que conduz à libertação da HISS. O modelo utilizado neste estudo foi o rato Wistar. A sensibilidade à insulina foi avaliada através do teste rápido de sensibilidade à insulina (RIST). A primeira hipótese de trabalho testada foi que a sequência de eventos que conduzem à secreção da HISS inicia-se com a activação do sistema parassimpático hepático seguida de activação do NOS hepático com subsequente produção de NO e activação do guanilato ciclase (GC). Observou-se que a administração de um dador de NO reverteu a resistência à insulina induzida, quer por inibição do NOS hepático, quer por antagonismo dos receptores muscarínicos com atropina. Em contraste, a resistência à insulina produzida por inibição do NOS hepático não foi revertida por administração intraportal de acetilcolina (ACh). Constatou-se que a inibição do GC hepático diminuiu a sensibilidade à insulina. Estes resultados sugerem que: a ACh libertada no fígado induz a síntese de NO hepático que conduz à libertação da HISS, que por sua vez é modulada pelo GC hepático. A libertação da HISS em resposta à insulina é regulada pelo estado prandial. Uma vez que os níveis hepáticos de glutationo (GSH) se encontram, tal como a HISS, diminuídos no estado de jejum e aumentados após a ingestão de uma refeição, testou-se a hipótese de que o GSH hepático está envolvido na secreção da HISS. Observou-se que a depleção do GSH hepático induziu resistência à insulina, comparável à obtida após inibição do NOS hepático. Estes resultados suportam a hipótese de que o GSH hepático desempenha um papel crítico na acção periférica da insulina. Considerando que, no estado de jejum, tanto os níveis de GSH hepático como os níveis de NO hepático são baixos, testou-se a hipótese de que a co-administração intraportal de um dador de GSH e de um dador de NO promove um aumento da sensibilidade à insulina no estado de jejum, devido ao restabelecimento do mecanismo da HISS. Observou-se que a administração sequencial de dadores de GSH e de NO no fígado provocou um aumento na sensibilidade à insulina, dependente da dose de dador de GSH administrada. Concluiu-se portanto que ambos, GSH e NO, são essenciais para que o mecanismo da HISS esteja completamente funcional. O GSH e o NO reagem para formar um S-nitrosotiol, o S-nitrosoglutationo (GSNO). Os resultados supra-mencionados conduziram à formulação da hipótese de que a secreção/acção da HISS depende da formação de GSNO. Observou-se que a administração intravenosa de S-nitrosotióis (RSNOs) aumentou a sensibilidade à insulina, em animais submetidos a um período de jejum, ao contrário da administração intraportal destes fármacos, o que RSNOs têm uma acção periférica, mas não hepática, na sensibilidade à insulina. Os resultados obtidos conduziram à reformulação da hipótese da HISS, sugerindo que a ingestão de uma refeição activa os nervos parassimpáticos hepáticos levando à libertação de ACh no fígado que, por sua vez activa o NOS. Simultaneamente, ocorre um aumento dos níveis de GSH hepático que reage com o NO hepático para formar um composto nitrosado, o GSNO. Este composto mimetiza a acção hipoglicemiante da HISS no músculo esquelético. SUMMARY Insulin action at the skeletal muscle depends on a hepatic parasympathetic reflex that promotes the release of a hepatic insulin sensitizing substance (HISS) from the liver, which contributes 55% to total insulin action. HISS action is modulated by hepatic nitric oxide (NO) and also by the prandial status so as to, in the immediate ostprandial state, HISS action is maximal, decreasing with the duration of fasting. HISS secretion may be inhibited by interruption of the hepatic parasympathetic reflex, achieved either by surgical denervation of the liver or by cholinergic blockade with atropine, or by prevention of hepatic NO release, using NO synthase (NOS) antagonists. The main objective of this work was to characterize the signal transduction pathways that lead to HISS secretion by the liver. Wistar rats were used and insulin sensitivity was evaluated using the rapid insulin sensitivity test (RIST). The first hypothesis tested was that the sequence of events that lead to HISS secretion starts with an increase in the hepatic parasympathetic tone, followed by the activation of hepatic NOS and subsequent triggering of guanylate cyclase (GC). We observed that insulin resistance produced either by muscarinic receptor antagonism with atropine or by hepatic NOS inhibition was reversed by the intraportal administration of an NO donor. In contrast, intraportal acetylcholine (ACh) did not restore insulin sensitivity after NOS inhibition. We also observed that GC inhibition lead to a decrease in insulin sensitivity.These results suggest that the release of ACh in the liver activates hepatic NO synthesis in order to allow HISS secretion, through a signaling pathway modulated by GC. HISS release in response to insulin is controlled by the prandial status. The second hypothesis tested was that glutathione (GSH) is involved in HISS secretion since the hepatic levels of GSH are, like HISS action, decreased in the fasted state and increased after ingestion of a meal. We observed that hepatic GSH depletion led to insulin resistance of the same magnitude of that observed after inhibition of hepatic NOS. These results support the hypothesis that hepatic GSH is crucial in peripheral insulin action. Since, in the fasted state, both hepatic GSH and NO levels are low, we tested the hypothesis that intraportal o-administration of a GSH donor and an NO donor enhances insulin sensitivity in fasted Wistar rats, by restoring HISS secretion. We observed that GSH and NO increased insulin sensitivity in a GSH dose-dependent manner. We concluded that HISS secretion requires elevated levels of both GSH and NO in the liver. GSH and NO react to form a S-nitrosothiol, S-nitrosoglutathione (GSNO). The last hypothesis tested in this work was that HISS secretion/ action depends on the formation of GSNO. We observed that intravenous administration of -nitrosothiols (RSNOs) increased insulin sensitivity in animals fasted for 24 h, in contrast with the intraportal administration of the drug. This result suggests that RSNOs enhanced insulin sensitivity through a peripheral, and not hepatic, mechanism. The results obtained led to a restructuring of the HISS hypothesis, suggesting that the ingestion of a meal triggers the hepatic parasympathetic nerves, leading to the release of Ach in the liver, which in turn activates NOS. Simultaneously, hepatic GSH levels increase and react with NO to form a nitrosated compound, GSNO. S-nitrosoglutathione mimics HISS hypoglycaemic action at the skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Electrical and Computer Engineering by the Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensification of agricultural productivity is an important challenge worldwide. However, environmental stressors can provide challenges to this intensification. The progressive occurrence of the cyanotoxins cylindrospermopsin (CYN) and microcystin-LR (MC-LR) as a potential consequence of eutrophication and climate change is of increasing concern in the agricultural sector because it has been reported that these cyanotoxins exert harmful effects in crop plants. A proteomic-based approach has been shown to be a suitable tool for the detection and identification of the primary responses of organisms exposed to cyanotoxins. The aim of this study was to compare the leaf-proteome profiles of lettuce plants exposed to environmentally relevant concentrations of CYN and a MC-LR/CYN mixture. Lettuce plants were exposed to 1, 10, and 100 lg/l CYN and a MC-LR/CYN mixture for five days. The proteins of lettuce leaves were separated by twodimensional electrophoresis (2-DE), and those that were differentially abundant were then identified by matrix-assisted laser desorption/ionization time of flight-mass spectrometry (MALDI-TOF/TOF MS). The biological functions of the proteins that were most represented in both experiments were photosynthesis and carbon metabolism and stress/defense response. Proteins involved in protein synthesis and signal transduction were also highly observed in the MC-LR/CYN experiment. Although distinct protein abundance patterns were observed in both experiments, the effects appear to be concentration-dependent, and the effects of the mixture were clearly stronger than those of CYN alone. The obtained results highlight the putative tolerance of lettuce to CYN at concentrations up to 100 lg/l. Furthermore, the combination of CYN with MC-LR at low concentrations (1 lg/l) stimulated a significant increase in the fresh weight (fr. wt) of lettuce leaves and at the proteomic level resulted in the increase in abundance of a high number of proteins. In contrast, many proteins exhibited a decrease in abundance or were absent in the gels of the simultaneous exposure to 10 and 100 lg/l MC-LR/CYN. In the latter, also a significant decrease in the fr. wt of lettuce leaves was obtained. These findings provide important insights into the molecular mechanisms of the lettuce response to CYN and MC-LR/CYN and may contribute to the identification of potential protein markers of exposure and proteins that may confer tolerance to CYN and MC-LR/CYN. Furthermore, because lettuce is an important crop worldwide, this study may improve our understanding of the potential impact of these cyanotoxins on its quality traits (e.g., presence of allergenic proteins).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Biology by Universidade Nova de Lisboa, Instituto de Tecnologia Química e Biológica, Instituto Gulbenkian de Ciência.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work uses surface imprinting to design a novel smart plastic antibodymaterial (SPAM) for Haemoglobin (Hb). Charged binding sites are described here for the first time to tailor plastic antibody nanostructures for a large size protein such as Hb. Its application to design small, portable and low cost potentiometric devices is presented. The SPAM material was obtained by linking Hb to silica nanoparticles and allowing its ionic interaction with charged vinyl monomers. A neutral polymeric matrix was created around these and the imprinted protein removed. Additional materials were designed in parallel acting as a control: a neutral imprinted material (NSPAM), obtained by removing the charged monomers from the procedure, and the Non-Imprinted (NI) versions of SPAM and NSPAM by removing the template. SEM analysis confirmed the surface modification of the silica nanoparticles. All materials were mixed with PVC/plasticizer and applied as selective membranes in potentiometric transduction. Electromotive force (emf) variations were detected only for selective membranes having a lipophilic anionic additive in the membrane. The presence of Hb inside these membranes was evident and confirmed by FTIR, optical microscopy and Raman spectroscopy. The best performance was found for SPAM-based selective membranes with an anionic lipophilic additive, at pH 5. The limits of detection were 43.8 mg mL 1 and linear responses were obtained down to 83.8 mg mL 1, with an average cationic slope of +40 mV per decade. Good selectivity was also observed against other coexisting biomolecules. The analytical application was conducted successfully, showing accurate and precise results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a novel surface Smart Polymer Antibody Material (SPAM) for Carnitine (CRT, a potential biomarker of ovarian cancer), tested for the first time as ionophore in potentiometric electrodes of unconventional configuration. The SPAM material consisted of a 3D polymeric network created by surface imprinting on graphene layers. The polymer was obtained by radical polymerization of (vinylbenzyl) trimethylammonium chloride and 4-styrenesulfonic acid (signaling the binding sites), and vinyl pivalate and ethylene glycol dimethacrylate (surroundings). Non-imprinted material (NIM) was prepared as control, by excluding the template from the procedure. These materials were then used to produce several plasticized PVC membranes, testing the relevance of including the SPAM as ionophore, and the need for a charged lipophilic additive. The membranes were casted over solid conductive supports of graphite or ITO/FTO. The effect of pH upon the potentiometric response was evaluated for different pHs (2-9) with different buffer compositions. Overall, the best performance was achieved for membranes with SPAM ionophore, having a cationic lipophilic additive and tested in HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) buffer, pH 5.1. Better slopes were achieved when the membrane was casted on conductive glass (-57.4 mV/decade), while the best detection limits were obtained for graphite-based conductive supports (3.6 × 10−5mol/L). Good selectivity was observed against BSA, ascorbic acid, glucose, creatinine and urea, tested for concentrations up to their normal physiologic levels in urine. The application of the devices to the analysis of spiked samples showed recoveries ranging from 91% (± 6.8%) to 118% (± 11.2%). Overall, the combination of the SPAM sensory material with a suitable selective membrane composition and electrode design has lead to a promising tool for point-of-care applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sol-gel chemistry allows the immobilization of organic molecules of biological origin on suibtable solid supports, permitting their integration into biosensing devices widening the possibility of local applications. The present work is an application of this principle, where the link between electrical receptor platform and the antibody acting as biorecognition element is made by sol-gel chemistry. The immunosensor design was targeted for carcinoembryonic antigen (CEA), an important biomarker for screening the colorectal cancer, by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SVW). The device displayed linear behavior to CEA in EIS and in SWV assays ranging from 0.50 to 1.5ng/mL, and 0.25 to 1.5ng/mL, respectively. The corresponding detection limits were 0.42 and 0.043 ng/mL. Raman spectroscopy was used to characterize the surface modifications on the conductive platform (FTO glass). Overall, simple sol-gel chemistry was effective at the biosensing design and the presented approach can be a potential method for screening CEA in point-of-care, due to the simplicity of fabrication, short response time and low cost. - See more at: http://www.eurekaselect.com/127192/article#sthash.m1AWhINx.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myoglobin (Mb) is among the cardiac biomarkers playing a major role in urgent diagnosis of cardiovascular diseases. Its monitoring in point-of-care is therefore fundamental. Pursuing this goal, a novel biomimetic ionophore for the potentiometric transduction of Mb is presented. It was synthesized by surface molecular imprinting (SMI) with the purpose of developing highly efficient sensor layers for near-stereochemical recognition of Mb. The template (Mb) was imprinted on a silane surface that was covalently attached to silica beads by means of self-assembled monolayers. First the silica was modified with an external layer of aldehyde groups. Then, Mb was attached by reaction with its amine groups (on the external surface) and subsequent formation of imine bonds. The vacant places surrounding Mb were filled by polymerization of the silane monomers 3-aminopropyltrimethoxysilane (APTMS) and propyltrimethoxysilane (PTMS). Finally, the template was removed by imine cleavage after treatment with oxalic acid. The results materials were finely dispersed in plasticized PVC selective membranes and used as ionophores in potentiometric transduction. The best analytical features were found in HEPES buffer of pH 4. Under this condition, the limits of detection were of 1.3 × 10−6 mol/L for a linear response after 8.0 × 10−7 mol/L with an anionic slope of −65.9 mV/decade. The imprinting effect was tested by preparing non-imprinted (NI) particles and employing these materials as ionophores. The resulting membranes showed no ability to detect Mb. Good selectivity was observed towards creatinine, sacarose, fructose, galactose, sodium glutamate, and alanine. The analytical application was conducted successfully and showed accurate and precise results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade−1 and detection limits of 3.91 × 10−5 mol L−1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7–62.0 mV decade−1 and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2–7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 3D-mirror synthetic receptor for ciprofloxacin host–guest interactions and potentiometric transduction is presented. The host cavity was shaped on a polymeric surface assembled with methacrylic acid or 2-vinyl pyridine monomers by radical polymerization. Molecularly imprinted particles were dispersed in 2-nitrophenyl octyl ether and entrapped in a poly(vinyl chloride) matrix. The sensors exhibited a near-Nernstian response in steady state evaluations. Slopes and detection limits ranged from 26.8 to 50.0 mV decade−1 and 1.0 × 10−5 to 2.7 × 10−5 mol L−1, respectively. Good selectivity was observed for trimethoprim, enrofloxacin, tetracycline, cysteine, galactose, hydroxylamine, creatinine, ammonium chloride, sucrose, glucose, sulphamerazine and sulfadiazine. The sensors were successfully applied to the determination of ciprofloxacin concentrations in fish and in pharmaceuticals. The method presented offered the advantages of simplicity, accuracy, applicability to colored and turbid samples and automation feasibility, as well as confirming the use of molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.