956 resultados para Scanline sampling technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there are many potential new insights to be gained through advancing research on the clients of male sex workers, significant social, ethical and methodological challenges to accessing this population exist. This research project case explores our attempts to recruit a population that does not typically form a cohesive or coherent 'community' and often avoids self-identifying to mitigate the stigma attached to buying sex. We used an arms-length recruitment campaign that focussed on directing potential participants to our study website, which could in turn lead them to participate in an anonymous telephone interview. Barriers to reaching male sex-work clients, however, demanded the evolution of our recruitment strategy. New technologies are part of the solution to accessing a hard-to-reach population, but they only work if researchers engage responsively. We also show how we conducted an in-depth interview with a client and discuss the value of using secondary data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of GNSS tracked Lagrangian drifters allows more realistic quantification of fluid motion and dispersion coefficients than Eulerian techniques because such drifters are analogues of particles that are relevant to flow field characterisation and pollutant dispersion. Using the fast growing Real Time Kinematic (RTK) positioning technique derived from Global Satellite Navigation Systems (GNSS), drifters are developed for high frequency (10 Hz) sampling with position estimates to centimetre accuracy. The drifters are designed with small size and less direct wind drag to follow the sub-surface flow which characterizes dispersion in shallow waters. An analysis of position error from stationary observation indicates that the drifter can efficiently resolve motion up to 1 Hz. The result of the field deployments of the drifter in conjunction with acoustic Eulerian devices shows higher estimate of the drifter streamwise velocities. Single particle statistical analysis of field deployments in a shallow estuarine zone yielded dispersion coefficients estimate comparable to those of dye tracer studies. The drifters capture the tidal elevation during field studies in a tidal estuary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A monolithic stationary phase was prepared via free radical co-polymerization of ethylene glycol dimethacrylate (EDMA) and glycidyl methacrylate (GMA) with pore diameter tailored specifically for plasmid binding, retention and elution. The polymer was functionalized. with 2-chloro-N,N-diethylethylamine hydrochloride (DEAE-Cl) for anion-exchange purification of plasmid DNA (pDNA) from clarified lysate obtained from E. coli DH5α-pUC19 culture in a ribonuclease/ protease-free environment. Characterization of the monolithic resin showed a porous material, with 68% of the pores existing in the matrix having diameters above 300 nm. The final product isolated from a single-stage 5 min anion-exchange purification was a pure and homogeneous supercoiled (SC) pDNA with no gDNA, RNA and protein contamination as confirmed by ethidium bromide agarose gel electrophoresis (EtBr-AGE), enzyme restriction analysis and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. This non-toxic technique is cGMP compatible and highly scalable for production of pDNA on a commercial level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance is a well-established tool for structural characterisation of porous media. Features of pore-space morphology can be inferred from NMR diffusion-diffraction plots or the time-dependence of the apparent diffusion coefficient. Diffusion NMR signal attenuation can be computed from the restricted diffusion propagator, which describes the distribution of diffusing particles for a given starting position and diffusion time. We present two techniques for efficient evaluation of restricted diffusion propagators for use in NMR porous-media characterisation. The first is the Lattice Path Count (LPC). Its physical essence is that the restricted diffusion propagator connecting points A and B in time t is proportional to the number of distinct length-t paths from A to B. By using a discrete lattice, the number of such paths can be counted exactly. The second technique is the Markov transition matrix (MTM). The matrix represents the probabilities of jumps between every pair of lattice nodes within a single timestep. The propagator for an arbitrary diffusion time can be calculated as the appropriate matrix power. For periodic geometries, the transition matrix needs to be defined only for a single unit cell. This makes MTM ideally suited for periodic systems. Both LPC and MTM are closely related to existing computational techniques: LPC, to combinatorial techniques; and MTM, to the Fokker-Planck master equation. The relationship between LPC, MTM and other computational techniques is briefly discussed in the paper. Both LPC and MTM perform favourably compared to Monte Carlo sampling, yielding highly accurate and almost noiseless restricted diffusion propagators. Initial tests indicate that their computational performance is comparable to that of finite element methods. Both LPC and MTM can be applied to complicated pore-space geometries with no analytic solution. We discuss the new methods in the context of diffusion propagator calculation in porous materials and model biological tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bearing faults are the most common cause of wind turbine failures. Unavailability and maintenance cost of wind turbines are becoming critically important, with their fast growing in electric networks. Early fault detection can reduce outage time and costs. This paper proposes Anomaly Detection (AD) machine learning algorithms for fault diagnosis of wind turbine bearings. The application of this method on a real data set was conducted and is presented in this paper. For validation and comparison purposes, a set of baseline results are produced using the popular one-class SVM methods to examine the ability of the proposed technique in detecting incipient faults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores a gap within the serious game design research. That gap is the ambiguity surrounding the process of aligning the instructional objectives of serious games with their core-gameplay i.e. the moment-to-moment activity that is the core of player interaction. A core-gameplay focused design framework is proposed that can work alongside existing, more broadly focused serious games design frameworks. The framework utilises an inquiry-based approach that allows the serious game designer to use key questions as a means to clearly outline instructional objectives with the core-gameplay. The use of this design framework is considered in the context of a small section of gameplay from an educational game currently in development. This demonstration of the framework brings shows how instructional objectives can be embedded into a serious games core-gameplay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique, localised bubbling zones on the water storage were found to produce over 50,000 mg m-2 d-1 and the areal extent ranged from 1.8 to 7% of the total reservoir area. The drivers behind these changes as well as lessons learnt from the system implementation are presented. This system exploits relatively cheap materials, sensing and computing and can be applied to a wide variety of aquatic and terrestrial systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-thermal plasma (NTP) has been introduced over the past several years as a promising method for nitrogen oxide (NOx) removal. The intent, when using NTP, is to selectively transfer input electrical energy to the electrons, and to not expend this in heating the entire gas stream, which generates free radicals through collisions, and promotes the desired chemical changes in the exhaust gases. The generated active species react with the pollutant molecules and decompose them. This paper reviews and summarizes relevant literature regarding various aspects of the application of {NTP} technology on {NOx} removal from exhaust gases. A comprehensive description of available scientific literature on {NOx} removal using {NTP} technology is presented, including various types of NTP, e.g. dielectric barrier discharge, corona discharge and electron beam. Furthermore, the combination of {NTP} with catalyst and adsorbent for better {NOx} removal efficiency is presented in detail. The removal of {NOx} from both simulated gases and real diesel engines is also considered in this review paper. As {NTP} is a new technique and is not yet commercialized, there is a need for more studies to be performed in this field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While the implementation of the IEC 61850 standard has significantly enhanced the performance of communications in electrical substations, it has also increased the complexity of the system. Subsequently, these added elaborations have introduced new challenges in relation to the skills and tools required for the design, test and maintenance of 61850-compatible substations. This paper describes a practical experience of testing a protection relay using a non-conventional test equipment; in addition, it proposes a third party software technique to reveal the contents of the packets transferred on the substation network. Using this approach, the standard objects can be linked and interpreted to what the end-users normally see in the IED and test equipment proprietary software programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthesis of high quality boron carbide (B4C) powders is achieved by carbothermal reduction of boron oxide (B2O3) from a condensed boric acid (H3BO3)/polyvinyl acetate (PVAc) product. Precursor solutions are prepared via free radical polymerisation of vinyl acetate (VA) monomer in methanol in the presence of dissolved H3BO3. A condensed product is then formed by flash evaporation under vacuum. As excess VA monomer is removed at the evaporation step, the polymerisation time is used to manage availability of carbon for reaction. This control of carbon facilitates dispersion of H3BO3 in solution due to the presence of residual VA monomer. B4C powders with very low residual carbon are formed at temperatures as low as 1,250 °C with a 4 hour residence time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the extent of works done on modelling port water collisions, not much research effort has been devoted to modelling collisions at port anchorages. This paper aims to fill this important gap in literature by applying the Navigation Traffic Conflict Technique (NTCT) for measuring the collision potentials in anchorages and for examining the factors contributing to collisions. Grounding on the principles of the NTCT, a collision potential measurement model and a collision potential prediction model were developed. These models were illustrated by using vessel movement data of the anchorages in Singapore port waters. Results showed that the measured collision potentials are in close agreement with those perceived by harbour pilots. Higher collision potentials were found in anchorages attached to shoreline and international fairways, but not at those attached to confined water. Higher operating speeds, larger numbers of isolated danger marks and day conditions were associated with reduction in the collision potentials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Anaemia is common in critically ill patients, and has a significant negative impact on patients' recovery. Blood conservation strategies have been developed to reduce the incidence of iatrogenic anaemic caused by sampling for diagnostic testing. Objectives Describe practice and local guidelines in adult, paediatric and neonatal Australian intensive care units (ICUs) regarding blood sampling and conservation strategies. Methods Cross-sectional descriptive study, conducted July 2013 over one week in single adult, paediatric and neonatal ICUs in Brisbane. Data were collected on diagnostic blood samples obtained during the study period, including demographic and acuity data of patients. Institutional blood conservation practice and guidelines were compared against seven evidence-based recommendations. Results A total of 940 blood sampling episodes from 96 patients were examined across three sites. Arterial blood gas was the predominant reason for blood sampling in each unit, accounting for 82% of adult, 80% of paediatric and 47% of neonatal samples taken (p <. 0.001). Adult patients had significantly more median [IQR] samples per day in comparison to paediatrics and neonates (adults 5.0 [2.4]; paediatrics 2.3 [2.9]; neonatal 0.7 [2.7]), which significantly increased median [IQR] blood sampling costs per day (adults AUD$101.11 [54.71]; paediatrics AUD$41.55 [56.74]; neonatal AUD$8.13 [14.95]; p <. 0.001). The total volume of samples per day (median [IQR]) was also highest in adults (adults 22.3. mL [16.8]; paediatrics 5.0. mL [1.0]; neonates 0.16. mL [0.4]). There was little information about blood conservation strategies in the local clinical practice guidelines, with the adult and neonatal sites including none of the seven recommendations. Conclusions There was significant variation in blood sampling practice and conservation strategies between critical care settings. This has implications not only for anaemia but also infection control and healthcare costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As conservatoire-style dance teaching has traditionally utilised a hierarchical approach through which the student must conform to the ideal requirements of the conventional technique, current discourse is beginning to question how dance training can develop technical acuity without stifling students' ability to engage creatively. In recent years, there has been growing interest in the field of somatics and its relationship to tertiary dance training due to the understanding that this approach supports creative autonomy by radically repositioning the student's relationship to embodied learning, skill acquisition, enquiry and performance. This research addresses an observable disjuncture between the skills of dancers graduating from tertiary training and Australian dance industry needs, which increasingly demand the co-creative input of the dancer in choreographic practice. Drawing from Action Research, this paper will discuss a project which introduces somatic learning approaches, primarily from Feldenkrais Method and Hanna Somatics, to first-year dance students in their transition into tertiary education. This paper acknowledges previous research undertaken, most specifically the Somdance Manual by the University of Western Sydney, while directing focus to the first-year student transition from private dance studio training into the pre-professional arena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin temperature is an important physiological measure that can reflect the presence of illness and injury as well as provide insight into the localised interactions between the body and the environment. The aim of this systematic review was to analyse the agreement between conductive and infrared means of assessing skin temperature which are commonly employed in in clinical, occupational, sports medicine, public health and research settings. Full-text eligibility was determined independently by two reviewers. Studies meeting the following criteria were included in the review: 1) the literature was written in English, 2) participants were human (in vivo), 3) skin surface temperature was assessed at the same site, 4) with at least two commercially available devices employed—one conductive and one infrared—and 5) had skin temperature data reported in the study. A computerised search of four electronic databases, using a combination of 21 keywords, and citation tracking was performed in January 2015. A total of 8,602 were returned. Methodology quality was assessed by 2 authors independently, using the Cochrane risk of bias tool. A total of 16 articles (n = 245) met the inclusion criteria. Devices are classified to be in agreement if they met the clinically meaningful recommendations of mean differences within ±0.5 °C and limits of agreement of ±1.0 °C. Twelve of the included studies found mean differences greater than ±0.5 °C between conductive and infrared devices. In the presence of external stimulus (e.g. exercise and/or heat) five studies foundexacerbated measurement differences between conductive and infrared devices. This is the first review that has attempted to investigate presence of any systemic bias between infrared and conductive measures by collectively evaluating the current evidence base. There was also a consistently high risk of bias across the studies, in terms of sample size, random sequence generation, allocation concealment, blinding and incomplete outcome data. This systematic review questions the suitability of using infrared cameras in stable, resting, laboratory conditions. Furthermore, both infrared cameras and thermometers in the presence of sweat and environmental heat demonstrate poor agreement when compared to conductive devices. These findings have implications for clinical, occupational, public health, sports science and research fields.