618 resultados para SIPHON STENOSIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary artery disease remains the leading cause of mortality in most industrialized countries, although age-standardized mortality related to coronary artery disease (CAD) has decreased by more than 40% during the last two decades. Coronary atherosclerosis may cause angina pectoris, myocardial infarction, heart failure, arrhythmia, and sudden death. Medical management of atherosclerosis and its manifestation aims at retardation of progression of plaque formation, prevention of plaque rupture, and subsequent events and treatment of symptoms, when these occur as well as treatment of the sequelae of the disease. Revascularization by either percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) is performed as treatment of flow-limiting coronary stenosis to reduce myocardial ischaemia. In high-risk patients with acute coronary syndromes (ACS), a routine invasive strategy with revascularization in most patients provides the best outcome with a significant reduction in death and myocardial infarction compared with an initial conservative strategy. Conversely, the benefit of revascularization among patients with chronic stable CAD has been called into question. This review will provide information that revascularization exerts favourable effects on symptoms, quality of life, exercise capacity, and survival, particularly in those with extensive CAD and documented moderate-to-severe ischaemia. Accordingly, CABG and PCI should be considered a valuable adjunct rather than an alternative to medical therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Applications of diffusion-weighted (DW) magnetic resonance (MR) imaging outside the brain have gained increasing importance in recent years. Owing to technical improvements in MR imaging units and faster sequences, the need for noninvasive imaging without contrast medium administration, mainly in patients with renal insufficiency, can be met successfully by applying this technique. DW MR imaging is quantified by the apparent diffusion coefficient (ADC), which provides information on diffusion and perfusion simultaneously. By using a biexponential fitting process of the DW MR imaging data, these two entities can be separated, because this type of fitting process can serve as an estimate of both the perfusion fraction and the true diffusion coefficient. DW MR imaging can be applied for functional evaluation of the kidneys in patients with acute or chronic renal failure. Impairment of renal function is accompanied by a decreased ADC. Acute ureteral obstruction leads to perfusion and diffusion changes in the affected kidney, and renal artery stenosis results in a decreased ADC. In patients with pyelonephritis, diffuse or focal changes in signal intensity are seen on the high-b-value images, with increased signal intensity corresponding to low signal intensity on the ADC map. The feasibility and reproducibility of DW MR imaging in patients with transplanted kidneys have already been demonstrated, and initial results seem to be promising for the assessment of allograft deterioration. Overall, performance of renal DW MR imaging, presuming that measurements are of high quality, will further boost this modality, particularly for early detection of diffuse renal conditions, as well as more accurate characterization of focal renal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carotid endarterectomy (CEA) reduces the risk of stroke in patients with symptomatic (>50%) and asymptomatic (>60%) carotid artery stenosis. Here we report the midterm results of a microsurgical non-patch technique and compare these findings to those in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The perioperative risk for redo surgical aortic valve replacement (S-AVR) in patients with severe aortic stenosis and prior coronary artery bypass grafting (CABG) is increased. Transcatheter aortic valve implantation (TAVI) represents an alternative. We assessed the perioperative and mid-term clinical outcome of patients undergoing S-AVR or TAVI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is rapidly evolving as an alternative treatment option for elderly patients with severe symptomatic aortic stenosis and excessive risk for surgical intervention. Transcatheter valve-in-valve implantation is an alternative approach to redo-surgery for patients with degeneration of a bioprosthetic valve. Herein are reported three cases of successful transcatheter aortic valve-in-valve implantation for severely regurgitant bioprosthetic valves with a clinical follow up of more than 12 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) has emerged as a treatment alternative to surgical aortic valve replacement in elderly high-risk patients with symptomatic severe aortic stenosis. In this patient population, rapid improvement or restoration of quality of life (QoL) is at least as important as improved clinical outcomes. The purpose of the present study was to assess changes in QoL in response to TAVI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the clinical outcome of a 46-year-old man referred for percutaneous closure of an atrial septal defect under transthoracic echocardiographic and fluoroscopic guidance, whose upper left pulmonary vein was erroneously obliterated using an Amplatzer atrial septal defect occluder. Various medical conditions have been associated with pulmonary vein stenosis including dyspnea on exertion or at rest, cough, and hemoptysis. However, there were no short- or long-term symptoms in this patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Assessment of elderly patients with severe aortic stenosis and decisions in terms of management strategy (conservative with or without balloon aortic valvuloplasty, transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement) are complex and warrant a multidisciplinary approach involving collaboration between experienced cardiac surgeons, interventional cardiologists, cardiac imaging specialists, anaesthesiologists, geriatricians and a specialised nursing staff. Patient history, comorbid conditions, perioperative risk stratification as well as anatomical and procedural considerations require careful review on an individual, case-by-case basis and have a major impact on treatment allocation. The aims of this article are to provide insights into the fundamental role of appropriate patient screening and selection, and to review the nature, management and prevention of the most important procedural complications associated with the TAVI procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.