956 resultados para SALIVARY FLOW-RATE


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työn tavoitteena oli kehittää Stora Enso Oyj:n Imatran tehtaille Wedge-pohjainen analysointityökalu, jolla voidaan hallita prosessi- ja päästötietojen yhteys nykyistä paremmin. Wedgeen määriteltiin päästömittauksia, olennaisia prosessimittauksia ja tarpeelliset laskennat kuormituksen ennustamiseksi lähtien tuotantoprosessien tilasta. Työssä tehtiin kemialliselle ja biologiselle jätevedenpuhdistamolle meneville jätevesille laskennallisia malleja, joita verrattiin mitattuihin arvoihin. Kemialliselle jätevedenpuhdistamolle meneville jätevesille tehtiin malli jäteveden virtaamalle. Biologiselle jätevedenpuhdistamolle meneville jätevesille tehtiin mallit jäteveden virtaamalle sekä COD-, AOX- ja alkuainekuormituksille. Alkuaineista työhön otettiin mukaan natrium, rikki ja kloori. Teoriaosassa on käsitelty sellu- ja paperitehtaiden vedenkäyttöä, tehtaan eri osastojen jätevesikuormitusta, jäteveden puhdistusmenetelmiä sekä prosessidatan käsittelymenetelmiä. Kokeellisessa osassa on esitelty mitattujen ja laskennallisten mallien yhteyttä. Suurin osa laskennallisista malleista näyttää seuraavan kohtuullisen hyvin mitattuja arvoja. Kokeellisessa osassa on myös havainnollistettu esimerkkien avulla mallien hyödyntämistä. Työn hyötynä on normaalien kuormitusvaihteluiden ja häiriöpäästöjen entistä tarkempi ja nopeampi erottelu. Pitkällä tähtäimellä Wedge-ohjelman avulla pystytään keskittämään jätevesikuormituksen vähentämistoimenpiteet olennaisimpiin kohteisiin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Läntisen Pien-Saimaan vesistön alueella on ilmennyt voimakasta sinileväkukintaa vuosina 2006 - 2009. Yksi tehokas keino vähentää sinilevien määrää ja parantaa vedenlaatua, onravinnepitoisuuksien alentaminen virtausohjauksen avulla. Tästä on 70 vuoden kokemus Pien- Saimaan itäosissa, joissa Vehkataipaleen pumppaamon virta on pitänyt vedenlaadun hyvänä huolimatta vesialuetta raskaasti rasittavasta puunjalostusteollisuudesta. Diplomityössä selvitetään mahdollisuuksia toteuttaa virtauksenohjausta myös läntisen Pien-Saimaan puolella, jolloin tavoitteena on vedenlaadun paraneminen. Vedenlaadun parantamista edellyttää myös Euroopan unionin vesipuitedirektiivi. Selvityksessä tarkasteltiin virtauksenohjauksen eri toteutusvaihtoehtoja ja arvioitiin näiden vaikutuksia eri alueiden vedenlaatuun. Tämän lisäksi kartoitettiin ja arvioitiin eri vaihtoehdoista aiheutuvia riskejä. Näiden tietojen pohjalta päädyttiin suositeltaviin virtauksenohjauksen toteutusvaihtoehtoihin, joita ovat Kolhonlahti – Kolinlahti välillä toteutettu pumppaus ja mahdollisen Kutilan kanavan rakentamisen yhteydessä Kopinsalmen pumppaamo. Kolhonlahti – Kolinlahti sijaitsee Pien-Saimaan koillisosassa lähellä Rehulaa. Muista tarkastelluista kohteista saatiin yhdistelemällä suositeltavaksi vaihtoehdoksi myös Vehkataipaleen pumppaamon virran kasvattaminen yhdistettynä Kirjamoinsalmen tai Kopinsalmen pumppaamoon. Tämän lisäksi eri vaihtoehdoille laadittiin alustava kustannustarkastelu. Selvityksessä käytettyjä menetelmiä ja tuloksia voidaan soveltaa myös muihin vastaavan tyyppisiin vesistöjen kunnostushankkeisiin. Työssä on lisäksi koottu yhteen yleistietoja Pien-Saimaasta ja sen tunnetuista virtauksista.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present paper reports a bacteria autonomous controlled concentrator prototype with a user-friendly interface for bench-top applications. It is based on a micro-fluidic lab-on-a-chip and its associated custom instrumentation, which consists in a dielectrophoretic actuator, to pre-concentrate the sample, and an impedance analyser, to measure concentrated bacteria levels. The system is composed by a single micro-fluidic chamber with interdigitated electrodes and a instrumentation with custom electronics. The prototype is supported by a real-time platform connected to a remote computer, which automatically controls the system and displays impedance data used to monitor the status of bacteria accumulation on-chip. The system automates the whole concentrating operation. Performance has been studied for controlled volumes of Escherichia coli (E. coli) samples injected into the micro-fluidic chip at constant flow rate of 10 μL/min. A media conductivity correcting protocol has been developed, as the preliminary results showed distortion of the impedance analyser measurement produced by bacterial media conductivity variations through time. With the correcting protocol, the measured impedance values were related to the quantity of bacteria concentrated with a correlation of 0.988 and a coefficient of variation of 3.1%. Feasibility of E. coli on-chip automated concentration, using the miniaturized system, has been demonstrated. Furthermore, the impedance monitoring protocol had been adjusted and optimized, to handle changes in the electrical properties of the bacteria media over time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study of the electrochemical degradation of the ranitidine was developed using an electrochemical reactor with a gas diffusion electrode (GDE) as cathode. The electrolysis experiments was performed at constant current (1 < A < 10) and flow rate of 200 L h-1. The process of drug degradation, chemical/electrochemical and electro-Fenton ways, using electrochemical reactor showed best efficiency at current values of > 4 A. The process reached a production of 630 mg L-1 of the H2O2 at 7 A. The ranitidine concentrations was reduced in 99.9% (HPLC) and chemical oxygen demand (COD) was reduced in 86.7% by electro-Fenton.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A high performance liquid chromatography (HPLC) method has been developed for a rapid determination of nimesulide in dissolution studies. Nimesulide was analyzed using 5 µm Lichrospher® RP-18 column (125 x 4 mm i.d.) and mobile phase acetonitrile: phosphate buffer pH=6.0 (55:45) at a flow-rate of 1.0 mL min-1. Detection was carried out at 300 nm at 25 ºC. The method was applied to analysis of nimesulide in in vitro release studies and showed a rapid and efficient analytical alternative for evaluation of dissolution profile of nimesulide.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study deals with phenol adsorption on chitin and chitosan and removal of contaminants from wastewater of a petroleum refinery. The adsorption kinetic data were best fitted to first- and second-order models for chitosan and chitin, respectively. The results of adsorption isotherms showed Langmuir model more appropriately described than a Freundlich model for both adsorbents. The adsorption capacity was 1.96 and 1.26 mg/g for chitin and chitosan, respectively. Maximum removal of phenol was about 70-80% (flow rate: 1.5 mL/min, bed height: 18.5 cm, and 30 mg/L of phenol. Wastewater treatment with chitin in a fixed-bed system showed reductions of about 52 and 92% for COD and oil and greases, and for chitosan 65 and 67%, respectively. The results show improvement of the effluent quality after treatment with chitin and chitosan.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C12 analytical column, maintained at 35 ºC, with water:acetonitrile:methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 μg/mL (r²=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Decomposition of carbon tetrachloride in a DC thermal plasma reactor was investigated in argon atmosphere. The operational parameters such as plasma torch power and argon flow rate versus CCl4 conversion were examined. The CCl4 net degradation was determined by GC-FID, the chlorine produced was quantified by iodometric titration, the solid carbon was characterised by Raman spectroscopy and by BET analysis. The solid carbon collected inside de plasma reactor was submitted to solid/liquid extraction and the desorbed species were identified by GC-MS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC) in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS). A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v), with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of gemifloxacin and diuretics (hydrochlorothiazide and furosemide) in bulk, dosage formulations and human serum at 232 nm. Chromatographic separation was achieved on Purospher Start C18 (250 mm x 4.6 mm, 5 µm) column using mobile phase, methanol: water: acetonitrile (70:25:5 v/v/v) adjusted to pH 3.0 via phosphoric acid 85% having flow rate of 0.8 mL min -1 at room temperature. Calibration curves were linear over range of 0.5-10 µg mL -1 with a correlation coefficient ± 0.999. LOD and LOQ were in the ranges of 0.75-2.56 µg mL -1. Intra and inter-run precision and accuracy results were 98.26 to 100.9.