919 resultados para Refusal of blood
Activation pattern of neutrophils from blood of elderly individuals with -related denture stomatitis
Resumo:
We have identified impaired neutrophils in elderly individuals which could be involved with -related denture stomatitis (DS), an oral infection predominantly caused by , affecting especially elderly individuals using dental prosthesis. However, specific mechanisms performed by neutrophil contributing to the susceptibility of the elderly to DS are not fully understood. This study evaluated activation features of blood neutrophils from elderly and young individuals with DS. Blood neutrophils cultured with . from elderly subjects secreted decreased levels of CXCL8. However, . challenged-neutrophils from DS patients produced high IL-4 and IL-10, and low GM-CSF levels, regardless of age. Additional elastase activity of neutrophils from both elderly groups was detected after incubation with . , but only neutrophils from elderly DS demonstrated high myeloperoxidase activity. Therefore, DS patients have affected neutrophils, and the advance of age intensifies these damages. In sumamry, individuals with -related denture stomatitis presented variation in the neutrophil phenotype and activation. Such alterations were more intense in neutrophils from infected elderly individuals.
Resumo:
Brossi P.M., Baccarin R.Y.A. & Massoco C.O. 2012 Do blood components affect the production of reactive oxygen species (ROS) by equine synovial cells in vitro? Pesquisa Veterinaria Brasileira 32(12):1355-1360. Departamento de Clinica Medica, Faculdade de Medicina Veterinaria e Zootecnia, Universidade de Sao Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, Butanta, Sao Paulo, SP 5508-210, Brazil. E-mail: baccarin@ usp.br Blood-derived products are commonly administered to horses and humans to treat many musculoskeletal diseases, due to their potential antioxidant and anti-inflammatory effects. Nevertheless, antioxidant effects have never been shown upon horse synovial fluid cells in vitro. If proved, this could give a new perspective to justify the clinical application of blood-derived products. The aim of the present study was to investigate the antioxidant effects of two blood-derived products - plasma (unconditioned blood product - UBP) and a commercial blood preparation (conditioned blood product - CBP)(4) - upon stimulated equine synovial fluid cells. Healthy tarsocrural joints (60) were tapped to obtain synovial fluid cells; these cells were pooled, processed, stimulated with lipopolysaccharide (LPS) or phorbol 12-myristate 13-acetate (PMA), and evaluated by flow cytometry for the production of reactive oxygen species (ROS). Upon addition of any blood-derived product here used - UBP and CBP - there was a significant decrease in the oxidative burst of synovial fluid cells (P<0.05). There was no difference between UBP and CBP effects. In conclusion, treatment of stimulated equine synovial cells with either UBP or CBP efficiently restored their redox equilibrium.
Resumo:
The study was designed to assess the effects of in vitro selenium addition on intracellular hydrogen peroxide production by neutrophils from the milk and blood of dairy cows. Blood from 10 dairy cows and 20 milk samples from five dairy cows were incubated with 0 mg (control) or 10μM of sodium selenite. Then, milk and blood neutrophils were submitted for evaluation of intracellular hydrogen peroxide production by flow cytometry using 2',7'-dichlorofluorescein diacetate as a probe. The selenium status of the animals was evaluated by determination of the blood glutathione peroxidase activity. The results of the present work showed that in vitro selenium supplementation leads to an enhancement in intracellular hydrogen peroxide production, which indicates an improvement in the bactericidal effects of blood and milk neutrophils even in cows with a selenium-adequate status. Thus, the present study showed that in vitro Se supplementation leads to an enhancement in intracellular hydrogen peroxide production, indicating an improvement in the bactericidal effects of blood and milk neutrophils in cows with Se-adequate status.
Resumo:
[EN] A universal O2 sensor presumes that compensation for impaired O2 delivery is triggered by low O2 tension, but in humans, comparisons of compensatory responses to altered arterial O2 content (CaO2) or tension (PaO2) have not been reported. To directly compare cardiac output (QTOT) and leg blood flow (LBF) responses to a range of CaO2 and PaO2, seven healthy young men were studied during two-legged knee extension exercise with control hemoglobin concentration ([Hb] = 144.4 +/- 4 g/l) and at least 1 wk later after isovolemic hemodilution ([Hb] = 115 +/- 2 g/l). On each study day, subjects exercised twice at 30 W and on to voluntary exhaustion with an FIO2 of 0.21 or 0.11. The interventions resulted in two conditions with matched CaO2 but markedly different PaO2 (hypoxia and anemia) and two conditions with matched PaO2 and different CaO2 (hypoxia and anemia + hypoxia). PaO2 varied from 46 +/- 3 Torr in hypoxia to 95 +/- 3 Torr (range 37 to >100) in anemia (P < 0.001), yet LBF at exercise was nearly identical. However, as CaO2 dropped from 190 +/- 5 ml/l in control to 132 +/- 2 ml/l in anemia + hypoxia (P < 0.001), QTOT and LBF at 30 W rose to 12.8 +/- 0.8 and 7.2 +/- 0.3 l/min, respectively, values 23 and 47% above control (P < 0.01). Thus regulation of QTOT, LBF, and arterial O2 delivery to contracting intact human skeletal muscle is dependent for signaling primarily on CaO2, not PaO2. This finding suggests that factors related to CaO2 or [Hb] may play an important role in the regulation of blood flow during exercise in humans.
Resumo:
Recent claims of blood vessels extracted from dinosaur fossils challenge classical views of soft-tissue preservation. Alternatively, these structures may represent postdepositional,diagenetic biofilms that grew on vascular cavity surfaces within the fossil. Similar red, hollow, tube-shaped structures were recovered from well-preserved and poorly-preserved (abraded, desiccated, exposed) Upper Cretaceous dinosaur fossils in this study. Integration of light microscopy, scanning electron microscopy, and energy dispersive x-ray spectroscopy was used to compare these vessel structures to the fossils from which they are derived. Vessel structures are typically 100-400 μm long, 0.5-1.5 μm thick, 10-40 μm in diameter and take on a wide range of straight, curved, andbranching morphologies. Interior surfaces vary from smooth to globular and typically contain spheres, rods, and fibrous structures (< 2 μm in diameter) incorporated into the surface. Exterior surfaces exhibit 2-μm-tall converging ridges, spaced 1-3 μm apart, that are sub-parallel to the long axis of the vessel structure. Fossil vascular cavities are typically coated with a smooth or grainy orange layer that shows a wide range of textures including smooth, globular, rough, ropy, and combinations thereof. Coatings tend to overlay secondary mineral crystals and framboids, confirming they are not primary structures of the fossil. For some cavity coatings, the surface that had been in contact with the bone exhibits a ridged texture, similar to that of vessel structures, having formed as a mold of the intravascular bone surface. Thus, vessel structures are interpreted as intact cavity coatings isolated after the fossil is demineralized. The presence of framboids and structures consistent in size and shape with bacteria cells, the abundance of iron in cavity coatings, and the growth of biofilms directly from the fossil that resemble respective cavity coatings support the hypothesis that vessel structures result from ironconsuming bacteria that form biofilms on the intravascular bone surfaces of fossil dinosaur bone. This also accounts for microstructures resembling osteocytes as some fossil lacunae are filled with the same iron oxide that comprises vessel structures andcoatings. Results of this study show that systematic, high-resolution SEM analyses of vertebrate fossils can provide improved insight on microtaphonomic processes, including the role of bacteria in diagenesis. These results conflict with earlier claims of dinosaurblood vessels and osteocytes.
Resumo:
This study aims to show that sensitive detection of ethyl glucuronide in dried blood spotted onto various surfaces after a period of 24h is feasible. At present, there is insufficient information how tightly ethyl glucuronide (EtG) binds to various materials and how easily it can be eluted. 4ml aliquots of blood samples obtained from seven volunteers after consumption of alcoholic beverages were applied to six different surfaces. After drying and a 24h-storage at 20±2°C the samples were re-dissolved in water, and EtG was subsequently analyzed by a LC-MS Paul-type ion trap. A comparison was made between dried and corresponding fluid samples. EtG was detectable in all subjects' samples following consumption of alcohol. EtG was also detectable after a storage time of four weeks at 4°C in whole blood that had been preserved with EDTA. EtG was detectable in all samples dried on different surfaces and its concentration remained relatively constant irrespective of the particular condition of the material. Detection of EtG in blood spots from the scene may indicate recent alcohol consumption in cases where collection of blood remained undone or could not be performed.
Resumo:
Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice.
Resumo:
Background: The clinical use of an enamel matrix derivative (EMD) has been shown to promote formation of new cementum, periodontal ligament (PDL), and bone and to significantly enhance the clinical outcomes after regenerative periodontal surgery. It is currently unknown to what extent the bleeding during periodontal surgery may compete with EMD adsorption to root surfaces. The aim of this study is to evaluate the effect of blood interactions on EMD adsorption to root surfaces mimicking various clinical settings and to test their ability to influence human PDL cell attachment and proliferation. Methods: Teeth extracted for orthodontic reasons were subjected to ex vivo scaling and root planing and treated with 24% EDTA, EMD, and/or human blood in six clinically related settings to determine the ability of EMD to adsorb to root surfaces. Surfaces were analyzed for protein adsorption via scanning electron microscopy and immunohistochemical staining with an anti-EMD antibody. Primary human PDL cells were seeded on root surfaces and quantified for cell attachment and cell proliferation. Results: Plasma proteins from blood samples altered the ability of EMD to adsorb to root surfaces on human teeth. Samples coated with EMD lacking blood demonstrated a consistent even layer of EMD adsorption to the root surface. In vitro experiments with PDL cells demonstrated improved cell attachment and proliferation in all samples coated with EMD (irrespective of EDTA) when compared to samples containing human blood. Conclusion: Based on these findings, it is advised to minimize blood interactions during periodontal surgeries to allow better adsorption of EMD to root surfaces.
Resumo:
OBJECTIVE: The use of vasopressors for treatment of hypotension in sepsis may have adverse effects on microcirculatory blood flow in the gastrointestinal tract. The aim of this study was to measure the effects of three vasopressors, commonly used in clinical practice, on microcirculatory blood flow in multiple abdominal organs in sepsis. DESIGN: Random order, cross-over design. SETTING: University laboratory. SUBJECTS: Eight sedated and mechanically ventilated pigs. INTERVENTIONS: Pigs were exposed to fecal peritonitis-induced septic shock. Mesenteric artery flow was measured using ultrasound transit time flowmetry. Microcirculatory flow was measured in gastric, jejunal, and colon mucosa; jejunal muscularis; and pancreas, liver, and kidney using multiple-channel laser Doppler flowmetry. Each animal received a continuous intravenous infusion of epinephrine, norepinephrine, and phenylephrine in a dose increasing mean arterial pressure by 20%. The animals were allowed to recover for 60 mins after each drug before the next was started. MEASUREMENTS AND MAIN RESULTS: During infusion of epinephrine (0.8 +/- 0.2 mug/kg/hr), mean arterial pressure increased from 66 +/- 5 to 83 +/- 5 mm Hg and cardiac index increased by 43 +/- 9%. Norepinephrine (0.7 +/- 0.3 mug/kg/hr) increased mean arterial pressure from 70 +/- 4 to 87 +/- 5 mm Hg and cardiac index by 41 +/- 8%. Both agents caused a significant reduction in superior mesenteric artery flow (11 +/- 4%, p < .05, and 26 +/- 6%, p < .01, respectively) and in microcirculatory blood flow in the jejunal mucosa (21 +/- 5%, p < .01, and 23 +/- 3%, p < .01, respectively) and in the pancreas (16 +/- 3%, p < .05, and 8 +/- 3%, not significant, respectively). Infusion of phenylephrine (3.1 +/- 1.0 mug/kg/min) increased mean arterial pressure from 69 +/- 5 to 85 +/- 6 mm Hg but had no effects on systemic, regional, or microcirculatory flow except for a 30% increase in jejunal muscularis flow (p < .01). CONCLUSIONS: Administration of the vasopressors phenylephrine, epinephrine, and norepinephrine failed to increase microcirculatory blood flow in most abdominal organs despite increased perfusion pressure and-in the case of epinephrine and norepinephrine-increased systemic blood flow. In fact, norepinephrine and epinephrine appeared to divert blood flow away from the mesenteric circulation and decrease microcirculatory blood flow in the jejunal mucosa and pancreas. Phenylephrine, on the other hand, appeared to increase blood pressure without affecting quantitative blood flow or distribution of blood flow.
Resumo:
Approximate entropy (ApEn) of blood pressure (BP) can be easily measured based on software analysing 24-h ambulatory BP monitoring (ABPM), but the clinical value of this measure is unknown. In a prospective study we investigated whether ApEn of BP predicts, in addition to average and variability of BP, the risk of hypertensive crisis. In 57 patients with known hypertension we measured ApEn, average and variability of systolic and diastolic BP based on 24-h ABPM. Eight of these fifty-seven patients developed hypertensive crisis during follow-up (mean follow-up duration 726 days). In bivariate regression analysis, ApEn of systolic BP (P<0.01), average of systolic BP (P=0.02) and average of diastolic BP (P=0.03) were significant predictors of hypertensive crisis. The incidence rate ratio of hypertensive crisis was 14.0 (95% confidence interval (CI) 1.8, 631.5; P<0.01) for high ApEn of systolic BP as compared to low values. In multivariable regression analysis, ApEn of systolic (P=0.01) and average of diastolic BP (P<0.01) were independent predictors of hypertensive crisis. A combination of these two measures had a positive predictive value of 75%, and a negative predictive value of 91%, respectively. ApEn, combined with other measures of 24-h ABPM, is a potentially powerful predictor of hypertensive crisis. If confirmed in independent samples, these findings have major clinical implications since measures predicting the risk of hypertensive crisis define patients requiring intensive follow-up and intensified therapy.
Resumo:
QUESTIONS UNDER STUDY: The risk of transfusion-transmitted HBV remains significant in Switzerland, where routine screening for hepatitis B virus (HBV) in blood donations relies solely on serological hepatitis B surface antigen (HBsAg) testing. This study was designed to determine the prevalence of anti-hepatitis B core (anti-HBc) and HBV nucleic acid testing (NAT) positive donations in two different Swiss donor populations, to help in deciding whether supplemental testing may bring additional safety to blood products. METHODS: In a first population of donors, 18143 consecutive donations were screened initially for HBsAg, anti-HBc (with one EIA assay) and with HBV NAT in minipools of 24 donations. The screening repeatedly reactive anti-HBc donations were then "confirmed" with two supplemental anti-HBc assays, an anti-hepatitis B surface assay (anti-HBs) and with single donation HBV NAT. In a second population of donors, 4186 consecutive donations were screened initially with two different anti-HBc assays in addition to the mandatory HBsAg screening test. The screening repeatedly reactive donations with at least one anti-HBc assay were tested for anti-HBs. RESULTS: In the first subset of 18143 donations, 17593 (97.0%) were negative for HBsAg, anti-HBc and HBV NAT in minipools. 549 (3.0%) were HBsAg and HBV NAT negative, but repeatedly reactive for anti-HBc. Of these 549 donations, 287 could not be "confirmed" with two additional anti-HBc assays and were negative with an anti-HBs assay, as well as with single donation HBV NAT. Only 211 (1.2% of the total screened donations) were "confirmed" positive with at least one of two supplemental anti-HBc assays. One repeatedly reactive HBsAg donation, from a first-time donor, was confirmed positive for HBsAg and anti-HBc, as well as with single donation HBV NAT. In the second subset of 4186 donations, 4014 (95.9%) were screened negative for HBsAg and for anti-HBc, tested with two independent anti-HBc assays. 172 donations (4.1%) were HBsAg negative but repeatedly reactive with at least one of the two anti-HBc assays. Of these 172 samples, 86 were reactive with the first anti-HBc assay only, 13 were reactive with the second anti-HBc assay only and 73 (1.7% of the total screened donations) were "confirmed" positive with both anti-HBc assays. CONCLUSION: The prevalence of anti-HBc "confirmed" positive donations in the two Swiss blood donor populations studied was low (<2%) and we found only one HBV NAT positive (HBsAg positive) donation among more than 18000. Concerning blood product safety, an increase in the deferral rate of less than 2% of anti-HBc positive, potentially infectious donors, would in our opinion make routine anti-HBc testing of blood donations cost-effective. There is however still a need for more specific assays to avoid an unacceptably high deferral rate of "false" positive donors. In contrast, the introduction of HBV NAT in minipools gives minimal benefit due to the inadequate sensitivity of the assay. It remains to evaluate more extensively the value of individual donation NAT, alone or in addition to anti-HBc, as supplemental testing in the context of several Swiss blood donor populations.
Resumo:
OBJECTIVE: Contact of blood with artificial surfaces and air as well as ischemia/reperfusion injury to the heart and lungs mediate systemic and local inflammation during cardiopulmonary bypass (CPB). Activation of complement and coagulation cascades leads to and accompanies endothelial cell damage. Therefore, endothelial-targeted cytoprotection with the complement inhibitor and endothelial protectant dextran sulfate (DXS, MW 5000) may attenuate CBP-associated myocardial and pulmonary injury. METHODS: Eighteen pigs (DXS, n=10; phosphate buffered saline [PBS], n=8) underwent standard cardiopulmonary bypass. After aortic cross-clamping, cardiac arrest was initiated with modified Buckberg blood cardioplegia (BCP), repeated after 30 and 60 min with BCP containing either DXS (300 mg/10 ml, equivalent to 5mg/kg) or 10 ml of PBS. Following 30 min reperfusion, pigs were weaned from CPB. During 2h of observation, cardiac function was monitored by echocardiography and invasive pressure measurements. Inflammatory and coagulation markers were assessed regularly. Animals were then sacrificed and heart and lungs analyzed. RESULTS: DXS significantly reduced CK-MB levels (43.4+/-14.8 ng/ml PBS, 35.9+/-11.1 ng/ml DXS, p=0.042) and significantly diminished cytokine release: TNFalpha (1507.6+/-269.2 pg/ml PBS, 222.1+/-125.6 pg/ml DXS, p=0.0071), IL1beta (1081.8+/-203.0 pg/ml PBS, 110.7+/-79.4 pg/ml DXS, p=0.0071), IL-6 (173.0+/-91.5 pg/ml PBS, 40.8+/-19.4 pg/ml DXS, p=0.002) and IL-8 (304.6+/-81.3 pg/ml PBS, 25.4+/-14.2 pg/ml DXS, p=0.0071). Tissue endothelin-1 levels were significantly reduced (6.29+/-1.90 pg/100mg PBS, 3.55+/-1.15 pg/100mg DXS p=0.030) as well as thrombin-anti-thrombin formation (20.7+/-1.0 microg/ml PBS, 12.8+/-4.1 microg/ml DXS, p=0.043). Also DXS reduced cardiac and pulmonary complement deposition, neutrophil infiltration, hemorrhage and pulmonary edema (measured as lung water content, 81+/-3% vs 78+/-3%, p=0.047), indicative of attenuated myocardial and pulmonary CPB-injury. Diastolic left ventricular function (measured as dp/dt(min)), pulmonary artery pressure (21+/-3 mmHg PBS, 19+/-3 mmHg DXS, p=0.002) and right ventricular pressure (21+/-1 mmHg PBS, 19+/-3 mmHg DXS p=0.021) were significantly improved with the use of DXS. CONCLUSIONS: Addition of DXS to the BCP solution ameliorates post-CPB injury and to a certain extent improves cardiopulmonary function. Endothelial protection in addition to myocyte protection may improve post-CPB outcome and recovery.
Resumo:
BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.
Resumo:
BACKGROUND AND AIMS: The splanchnic circulation has an important function in the body under both physiological and pathophysiological conditions. Despite its importance, no reliable noninvasive procedures for estimating splanchnic circulation have been established. The aim of this study was to evaluate MRI as a tool for assessing intra-abdominal blood flows of the aorta, portal vein (VPO) and the major intestinal and hepatic vessels. METHODS: In nine healthy volunteers, the proximal aorta (AOP) and distal abdominal aorta (AOD), superior mesenteric artery (SAM), celiac trunk (CTR), hepatic arteries (common and proper hepatic arteries, AHC and AHP, respectively), and VPO were localized on contrast-enhanced magnetic resonance angiography images. Volumetric flow was measured using a two-dimensional cine echocardiogram-gated phase contrast technique. Measurements were taken before and 30 min after continuous intravenous infusion of somatostatin (250 microg/h) and were independently evaluated by two investigators. RESULTS: Blood flow measured by MRI in the VPO, SAM, AOP, AHP, and CTR significantly decreased after drug infusion. Flows in the AOD and AHC showed a tendency to decrease (P>0.05). Interrater agreement on flows in MRI was very good for large vessels (VPO, AOP, and AOD), with a concordance correlation coefficient of 0.94, as well as for smaller vessels such as the CTR, AHC, AHP, and SAM (concordance correlation coefficient =0.78). CONCLUSION: Somatostatin-induced blood flow changes in the splanchnic region were reliably detected by MRI. MRI may be useful for the noninvasive assessment of blood flow changes in the splanchnic region.
Resumo:
OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.