975 resultados para Procédé tandem


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An assay using high performance liquid chromatography (HPLC)-electrospray ionization-tandem mass spectrometry (ESI-MS-MS) was developed for simultaneously determining concentrations of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone, in 50 mul samples of rat serum. Deuterated (d(3)) analogues of each compound were used as internal standards. Samples were treated with acetonitrile to precipitate plasma proteins: acetonitrile was removed from the supernatant by centrifugal evaporation before analysis. Limits of quantitation (ng/ml) and their between-day accuracy and precision (%deviation and %CV) were-morphine, 3.8 (4.3% and 7.6%); morphine-3-glucuronide, 5.0 (4.5% and 2.9%); oxycodone, 4.5 (0.4% and 9.3%); noroxycodone, 5.0 (8.5% and 4.6%). (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance liquid chromatography coupled by an electrospray ion source to a tandem mass spectrometer (HPLC-EST-MS/ MS) is the current analytical method of choice for quantitation of analytes in biological matrices. With HPLC-ESI-MS/MS having the characteristics of high selectivity, sensitivity, and throughput, this technology is being increasingly used in the clinical laboratory. An important issue to be addressed in method development, validation, and routine use of HPLC-ESI-MS/MS is matrix effects. Matrix effects are the alteration of ionization efficiency by the presence of coeluting substances. These effects are unseen in the chromatograrn but have deleterious impact on methods accuracy and sensitivity. The two common ways to assess matrix effects are either by the postextraction addition method or the postcolumn infusion method. To remove or minimize matrix effects, modification to the sample extraction methodology and improved chromatographic separation must be performed. These two parameters are linked together and form the basis of developing a successful and robust quantitative HPLC-EST-MS/MS method. Due to the heterogenous nature of the population being studied, the variability of a method must be assessed in samples taken from a variety of subjects. In this paper, the major aspects of matrix effects are discussed with an approach to address matrix effects during method validation proposed. (c) 2004 The Canadian Society of Clinical Chemists. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new method for the interrogation of large arrays of Bragg grating sensors. Eight gratings operating between the wavelengths of 1533 and 1555 nm have been demultiplexed. An unbalanced Mach—Zehnder interferometer illuminated by a single low-coherence source provides a high-phase-resolution output for each sensor, the outputs of which are sequentially selected in wavelength by a tunable Fabry-Perot interferometer. The minimum detectable strain measured was 90 ne-vHz at 7 Hz for a wavelength of 1535 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel 16-quadrature amplitude modulation (QAM) transmitter based on two cascaded IQ modulators driven by four separate binary electrical signals. The proposed 16-QAM transmitter features scalable configuration and stable performance with simple bias-control. Generation of 16-QAM signals at 40 Gbaud is experimentally demonstrated for the first time and visualized with a high speed constellation analyzer. The proposed modulator is also compared to two other schemes. We investigate the modulator bandwidth requirements and tolerance to accumulated chromatic dispersion through numerical simulations, and the minimum theoretical insertion attenuation is calculated analytically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monoamines have an important role in neural plasticity, a key factor in cortical pain processing that promotes changes in neuronal network connectivity. Monoamine oxidase type A (MAOA) is an enzyme that, due to its modulating role in monoaminergic activity, could play a role in cortical pain processing. The X-linked MAOA gene is characterized by an allelic variant of length, the MAOA upstream Variable Number Tandem Repeat (MAOA-uVNTR) region polymorphism. Two allelic variants of this gene are known, the high-activity MAOA (HAM) and low-activity MAOA (LAM). We investigated the role of MAOA-uVNTR in cortical pain processing in a group of healthy individuals measured by the trigeminal electric pain-related evoked potential (tPREP) elicited by repeated painful stimulation. A group of healthy volunteers was genotyped to detect MAOA-uVNTR polymorphism. Electrical tPREPs were recorded by stimulating the right supraorbital nerve with a concentric electrode. The N2 and P2 component amplitude and latency as well as the N2-P2 inter-peak amplitude were measured. The recording was divided into three blocks, each containing 10 consecutive stimuli and the N2-P2 amplitude was compared between blocks. Of the 67 volunteers, 37 were HAM and 30 were LAM. HAM subjects differed from LAM subjects in terms of amplitude of the grand-averaged and first-block N2-P2 responses (HAM>LAM). The N2-P2 amplitude decreased between the first and third block in HAM subjects but not LAM subjects. The MAOA-uVNTR polymorphism seemed to influence the brain response in a repeated tPREP paradigm and suggested a role of the MAOA as a modulator of neural plasticity related to cortical pain processing. Monoamines have an important role in neural plasticity, a key factor in cortical pain processing that promotes changes in neuronal network connectivity. Monoamine oxidase type A (MAOA) is an enzyme that, due to its modulating role in monoaminergic activity, could play a role in cortical pain processing. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new method for the interrogation of large arrays of Bragg grating sensors. Eight gratings operating between the wavelengths of 1533 and 1555 nm have been demultiplexed. An unbalanced Mach—Zehnder interferometer illuminated by a single low-coherence source provides a high-phase-resolution output for each sensor, the outputs of which are sequentially selected in wavelength by a tunable Fabry-Perot interferometer. The minimum detectable strain measured was 90 ne-vHz at 7 Hz for a wavelength of 1535 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to demonstrate the applicability of reduced-size STR (Miniplex) primer sets to challenging samples and to provide the forensic community with new information regarding the analysis of degraded and inhibited DNA. The Miniplex primer sets were validated in accordance with guidelines set forth by the Scientific Working Group on DNA Analysis Methods (SWGDAM) in order to demonstrate the scientific validity of the kits. The Miniplex sets were also used in the analysis of DNA extracted from human skeletal remains and telogen hair. In addition, a method for evaluating the mechanism of PCR inhibition was developed using qPCR. The Miniplexes were demonstrated to be a robust and sensitive tool for the analysis of DNA with as low as 100 pg of template DNA. They also proved to be better than commercial kits in the analysis of DNA from human skeletal remains, with 64% of samples tested producing full profiles, compared to 16% for a commercial kit. The Miniplexes also produced amplification of nuclear DNA from human telogen hairs, with partial profiles obtained from as low as 60 pg of template DNA. These data suggest smaller PCR amplicons may provide a useful alternative to mitochondrial DNA for forensic analysis of degraded DNA from human skeletal remains, telogen hairs, and other challenging samples. In the evaluation of inhibition by qPCR, the effect of amplicon length and primer melting temperature was evaluated in order to determine the binding mechanisms of different PCR inhibitors. Several mechanisms were indicated by the inhibitors tested, including binding of the polymerase, binding to the DNA, and effects on the processivity of the polymerase during primer extension. The data obtained from qPCR illustrated a method by which the type of inhibitor could be inferred in forensic samples, and some methods of reducing inhibition for specific inhibitors were demonstrated. An understanding of the mechanism of the inhibitors found in forensic samples will allow analysts to select the proper methods for inhibition removal or the type of analysis that can be performed, and will increase the information that can be obtained from inhibited samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannabis sativa is the most frequently used of all illicit drugs in the United States. Cannabis has been used throughout history for its stems in the production of hemp fiber, for its seed for oil and food, and for its buds and leaves as a psychoactive drug. Short tandem repeats (STRs), were chosen as molecular markers because of their distinct advantages over other genetic methods. STRs are co-dominant, can be standardized such that reproducibility between laboratories can be easily achieved, have a high discrimination power and can be multiplexed. ^ In this study, six STR markers previously described for Cannabis were multiplexed into one reaction. The multiplex reaction was able to individualize 98 Cannabis samples (14 hemp and 84 marijuana, authenticated as originating from 33 of the 50 United States) and detect 29 alleles averaging 4.8 alleles per loci. The data did not relate the samples from the same state to each other. This is the first study to report a single reaction six-plex and apply it to the analysis of almost 100 Cannabis samples of known geographic collection site. ^