960 resultados para Problem Detection Study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In studies assessing the trends in coronary events, such as the World Health Organization (WHO) MONICA Project (multinational MONItoring of trends and determinants of CArdiovascular disease), the main emphasis has been on coronary deaths and non-fatal definite myocardial infarctions (MI). It is, however, possible that the proportion of milder MIs may be increasing because of improvements in treatment and reductions in levels of risk factors. We used the MI register data of the WHO MONICA Project to investigate several definitions for mild non-fatal MIs that would be applicable in various settings and could be used to assess trends in milder coronary events. Of 38 populations participating in the WHO MONICA MI register study, more than half registered a sufficiently wide spectrum of events that it was possible to identify subsets of milder cases. The event rates and case fatality rates of MI are clearly dependent on the spectrum of non-fatal MIs, which are included. On clinical grounds we propose that the original MONICA category ''non-fatal possible MI'' could bt:divided into two groups: ''non fatal probable MI'' and ''prolonged chest pain.'' Non-fatal probable MIs are cases, which in addition to ''typical symptoms'' have electrocardiogram (EGG) or enzyme changes suggesting cardiac ischemia, but not severe enough to fulfil the criteria for non-fatal definite MI In more than half of the MONICA Collaborating Centers, the registration of MI covers these milder events reasonably well. Proportions of non-fatal probable MIs vary less between populations than do proportions of non fatal possible MIs. Also rates of non-fatal probable MI are somewhat more highly correlated with rates of fatal events and non-fatal definite MI. These findings support the validity of the category of non-fatal probable MI. In each center the increase in event rates and the decrease in case-fatality due to the inclusion of non-fatal probable MI was lar er for women than men. For the WHO MONICA Project and other epidemiological studies the proposed category of non-fatal probable MIs can be used for assessing trends in rates of milder MI. Copyright (C) 1997 Elsevier Science Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The longest open reading frame of PKHD1 (polycystic kidney and hepatic disease 1), the autosomal recessive polycystic kidney disease (ARPKD) gene, encodes a single-pass, integral membrane protein named polyductin or fibrocystin. A fusion protein comprising its intracellular C-terminus, FP2, was previously used to raise a polyclonal antiserum shown to detect polyductin in several human tissues, including liver. In the current study, we aimed to investigate by immunohistochemistry the detailed polyductin localization pattern in normal (ductal plate [DP], remodelling ductal plate [RDP], remodelled bile ducts) and abnormal development of the primitive intrahepatic biliary system, known as ductal plate malformation (DPM). This work also included the characterization of polyductin expression profile in various histological forms of neonatal and infantile cholestasis, and in cholangiocellular carcinoma (CCC) and hepatocellular carcinoma (HCC). We detected polyductin expression in the intrahepatic biliary system during the DP and the RDP stages as well as in DPM. No specific staining was found at the stage of remodelled bile ducts. Polyductin was also detected in liver biopsies with neonatal cholestasis, including mainly biliary atresia and neonatal hepatitis with ductular reaction as well as congenital hepatic fibrosis. In addition, polyductin was present in CCC, whereas it was absent in HCC. Polyductin was also co-localized in some DP cells together with oval stem cell markers. These results represent the first systematic study of polyductin expression in human pathologies associated with abnormal development of intrahepatic biliary tree, and support the following conclusions: (i) polyductin expression mirrors developmental properties of the primitive intrahepatic biliary system; (ii) polyductin is re-expressed in pathological conditions associated with DPM and (iii) polyductin might be a potential marker to distinguish CCC from HCC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary C4d deposition has been recognized as a marker of antibody-mediated rejection (AMR). Although the detection of capillary C4d by means of immunofluorescence (IF) in cryostat sections is well established, frozen tissue is not always available, thus limiting the diagnosis of AMR. The aim of the present study was to analyze different techniques for C4d staining and the prevalence of C4d in renal allograft biopsies. Detection of C4d was carried out using IF or immunohistochemistry (IHC) on frozen and paraffin sections of renal allograft biopsies available from the same patients. Biopsies obtained from 20 patients were classified into 3 groups: no rejection, acute rejection, and chronic allograft nephropathy (CAN). The capillary C4d deposition prevalence in frozen-IF, considered the gold standard technique for C4d detection, was 45% (9/20 cases). Compared with frozen-IF, the frozen-IHC technique presented an 85% concordance rate (17/20 cases; r =.70; P <.001; sensitivity = 77.8%; specificity = 90.9%). The paraffin-IF technique showed similar results, with an 80% concordance rate (16/20 cases; r =.64; P <.005; sensitivity = 55.6%; specificity = 100%), whereas C4d detection occurred in only 65% of paraffin-IHC cases (13/20; r =.30; not significant; sensitivity = 66.7%; specificity = 63.6%). No capillary C4d deposition was detected in cases without evidence of rejection. However, 4/7 cases (57%) of acute rejection were C4d positive. In the CAN group, 5111 cases (45%) were C4d positive. In conclusion, these results demonstrated that frozen-IHC and paraffin-IF can be considered alternative techniques to frozen-IF for C4d detection. The paraffin-IHC technique displayed the lowest concordance rate for C4d detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The histopathological counterpart of white matter hyperintensities is a matter of debate. Methodological and ethical limitations have prevented this question to be elucidated. We want to introduce a protocol applying state-of-the-art methods in order to solve fundamental questions regarding the neuroimaging-neuropathological uncertainties comprising the most common white matter hyperintensities [WMHs] seen in aging. By this protocol, the correlation between signal features in in situ, post mortem MRI-derived methods, including DTI and MTR and quantitative and qualitative histopathology can be investigated. We are mainly interested in determining the precise neuroanatomical substrate of incipient WMHs. A major issue in this protocol is the exact co-registration of small lesion in a tridimensional coordinate system that compensates tissue deformations after histological processing. The protocol is based on four principles: post mortem MRI in situ performed in a short post mortem interval, minimal brain deformation during processing, thick serial histological sections and computer-assisted 3D reconstruction of the histological sections. This protocol will greatly facilitate a systematic study of the location, pathogenesis, clinical impact, prognosis and prevention of WMHs. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the effectiveness of a group-based attention and problem solving (APS) treatment approach to executive impairments in patients with frontal lobe lesions was investigated. Thirty participants with lesions in the frontal lobes, 16 with left frontal (LF) and 14 with right frontal (RF) lesions, were allocated into three groups, each with 10 participants. The APS treatment was initially compared to two other control conditions, an information/education (IE) approach and treatment-as-usual or traditional rehabilitation (TR), with each of the control groups subsequently receiving the APS intervention in a crossover design. This design allowed for an evaluation of the treatment through assessment before and after treatment and on follow up, six months later. There was an improvement on some executive and functional measures after the implementation of the APS programme in the three groups. Size, and to a lesser extent laterality, of lesion affected baseline performance on measures of executive function, but there was no apparent relationship between size, laterality or site of lesion and level of benefit from the treatment intervention. The results were discussed in terms of models of executive functioning and the effectiveness of domain specific interventions in the rehabilitation of executive dysfunction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose LATIN is a multinational case-control study designed to identify risk factors for agranulocytosis and to estimate the incidence rate of the disease in some Latin American countries. Methods Each study site in Brazil, Argentina and Mexico conducted an active search of agranulocytosis patients in hematology clinics and looked for possible associations with drug use. Results The overall incidence rate was 0.38 cases per 1 million inhabitant-years. Agranulocytosis patients more often took medications already associated with agranulocytosis than controls (p=0.01), mainly methimazole (OR 44.2, 95% CI 6.8 to infinity). The population attributable risk percentage (etiologic fraction) was 56%. The use of nutrient supplements was more frequent among patients than controls (p=0.03). Conclusions Agranulocytosis seems to be very rare in Latin America. The lower than expected number of cases identified during the study period precluded estimation of the risk associated to individual drugs, with the exception of methimazol. However, this is the longest series of agranulocytosis cases ever gathered in Latin America, and information on drug exposures was collected prospectively. The conclusion is that drug-induced agranulocytosis does not seem to be a major public health problem in the study regions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Helicobacter pylori ClariRes assay is a novel commercially available real-time PCR assay allowing H. pylori detection and clarithromycin susceptibility testing in either gastric biopsy or stool specimens. Objective: The aim of this study was to validate the novel biprobe real-time assay in stool specimens from 217 dyspeptic children. Methods: DNA from gastric biopsies and stool specimens were obtained and submitted to the biprobe real time assay for H. pylori detection and clarithromycin susceptibility testing. Results: The sensitivity, specificity, and test accuracy were 69, 100 and 93.9% for the detection of H. pylori infection and 83.3, 100 and 95.6%, for detection of clarithromycin resistance. Conclusion: This assay proved to be appropriate for H. pylori clarithromycin susceptibility testing, particularly in children populations where a high prevalence of clarithromycin-resistant strains is suspected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Sensitized patients (pts) may develop acute antibody-mediated rejection (AMR) due to preformed donor-specific antibodies, undetected by pre-transplant complement-dependent cytotoxicity (CDC) crossmatch (XM). We hypothesized that C4d staining in 1-h post-reperfusion biopsies (1-h Bx) could detect early complement activation in the renal allograft due to preformed donor-specific antibodies. Methods. To test this hypothesis, renal transplants (n = 229) performed between June 2005 and December 2007 were entered into a prospective study of 1-h Bx and stained for C4d by immunofluorescence. Transplants were performed against a negative T-cell CDC-XM with the exception of three cases with a positive B-cell XM. Results. All 229 1-h Bx stained negative for C4d. Fourteen pts (6%) developed AMR. None of the 14 protocol 1-h Bx stained positive for C4d in peritubular capillaries (PTC). However, all indication biopsies-that diagnosed AMR-performed at a median of 8 days after transplantation stained for C4d in PTC. Conclusions. These data show that C4d staining in 1-h Bx is, in general, not useful for the early detection of AMR when CDC-XM is negative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dacryocystorhinostomy is the treatment of choice for the obstruction of the lachrymal apparatus. At the end of last century, the development of the endoscopic instruments for nasosinusal surgery has made it possible to do it through the endoscopic pathway. Nonetheless, anatomical variations make it difficult to have reproducibility endonasaly. Aim: study the endoscopic anatomy of the lachrymal fossa through transillumination of the common canaliculus. Study design: experimental. Materials and Methods: we dissected 40 lachrymal pathways from 20 human cadavers, in three stages: 1. identification and dilation of the lachrymal canaliculus. 2 Optic fiber beam introduction; 3 - endoscopic dissection of the lachrymal sac, describing its position. Results: the most frequent position of the lachrymal sac was between the free border of the middle turbinate and its insertion immediately underneath it. The maxillary line was seen in 95% of the cases. Septoplasty was needed in 12.5%, unicifectomy in 35% and middle turbinectomy in 7.5%. Conclusion: Although the lachrymal sac has a more frequent location, its position varied considerably. The transillumination of the common canaliculus proved useful, solving the problem of the anatomical variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Verbal fluency (VF) tasks are simple and efficient clinical tools to detect executive dysfunction and lexico-semantic impairment. VF tasks are widely used in patients with suspected dementia, but their accuracy for detection of mild cognitive impairment (MCI) is still under investigation. Schooling in particular may influence the subject`s performance. The aim of this study was to compare the accuracy of two semantic categories (animals and fruits) in discriminating controls, MCI patients and Alzheimer`s disease (AD) patients. Methods: 178 subjects, comprising 70 controls (CG), 70 MCI patients and 38 AD patients, were tested on two semantic VF tasks. The sample was divided into two schooling groups: those with 4-8 years of education and those with 9 or more years. Results: Both VF tasks - animal fluency (VFa) and fruits fluency (VFf) - adequately discriminated CG from AD in the total sample (AUC = 0.88 +/- 0.03, p < 0.0001) and in both education groups, and high educated MCI from AD (VFa: AUC = 0.82 +/- 0.05, p < 0.0001; VFf: AUC = 0.85 +/- 0.05, p < 0.0001). Both tasks were moderately accurate in discriminating CG from MCI (VFa: AUC = 0.68 +/- 0.04, p < 0.0001 - VFf:AUC = 0.73 +/- 0.04, p < 0.0001) regardless of the schooling level, and MCI from AD in the total sample (VFa: AUC = 0.74 +/- 0.05, p < 0.0001; VFf: AUC = 0.76 +/- 0.05, p < 0.0001). Neither of the two tasks differentiated low educated MCI from AD. In the total sample, fruits fluency best discriminated CG from MCI and MCI from AD; a combination of the two improved the discrimination between CG and AD. Conclusions: Both categories were similar in discriminating CG from AD; the combination of both categories improved the accuracy for this distinction. Both tasks were less accurate in discriminating CG from MCI, and MCI from AD.