998 resultados para Pressure platform
Resumo:
The calculation of the transitional boundary layer requires estimates of the extent of the transition zone, which in turn depends on the rate at which turbulent spots are formed. This rate has been found to scale with local boundary layer thickness and viscosity, and the resulting nondimensional group (called crumble) is a function of the pressure gradient, among other parameters. Available experimental data are analyzed to show that the crumble increases slowly with increasing favorable pressure gradients, being about four times as large as in constant-pressure flow when the Thwaites pressure gradient parameter at the effective origin of the resulting turbulent boundary layer is 0.1 and when transition is driven by free-stream turbulence.
Resumo:
Effect of pressure on the dielectric properties of ferroelectric DTAAP has been carried out upto about 4 Kbars. The dTc/dP value was found to be -1.65°C/Kbar. It was noted that the value of dTc/dP is 1.63 times smaller in DTAAP as compared to TAAP, where as Tc itself is 1.13 times larger.
Resumo:
The effect of pressure on non-ohmic conduction and electrical switching in the charge transfer complex benzidine-DDQ has been studied up to a pressure of 7·66 GPa at a temperature of 300K. Pulsed I-V measurements reveal heating contribution to non-ohmicity and switching. At high electric fields (∼ 3 × 103 V/cm), the sample switches from high resistance OFF state of several kiloohms to low resistance ON state of several ohms. Temperature dependence of conductivity of ON state show semiconducting behaviour with very low activation energy.
Resumo:
One of the most important factors that affect the pointing of precision payloads and devices in space platforms is the vibration generated due to static and dynamic unbalanced forces of rotary equipments placed in the neighborhood of payload. Generally, such disturbances are of low amplitude, less than 1 kHz, and are termed as ‘micro-vibrations’. Due to low damping in the space structure, these vibrations have long decay time and they degrade the performance of payload. This paper addresses the design, modeling and analysis of a low frequency space frame platform for passive and active attenuation of micro-vibrations. This flexible platform has been designed to act as a mount for devices like reaction wheels, and consists of four folded continuous beams arranged in three dimensions. Frequency and response analysis have been carried out by varying the number of folds, and thickness of vertical beam. Results show that lower frequencies can be achieved by increasing the number of folds and by decreasing the thickness of the blade. In addition, active vibration control is studied by incorporating piezoelectric actuators and sensors in the dynamic model. It is shown using simulation that a control strategy using optimal control is effective for vibration suppression under a wide variety of loading conditions.
Resumo:
In this paper, we present an algebraic method to study and design spatial parallel manipulators that demonstrate isotropy in the force and moment distributions. We use the force and moment transformation matrices separately, and derive conditions for their isotropy individually as well as in combination. The isotropy conditions are derived in closed-form in terms of the invariants of the quadratic forms associated with these matrices. The formulation is applied to a class of Stewart platform manipulator, and a multi-parameter family of isotropic manipulators is identified analytically. We show that it is impossible to obtain a spatially isotropic configuration within this family. We also compute the isotropic configurations of an existing manipulator and demonstrate a procedure for designing the manipulator for isotropy at a given configuration.
Resumo:
Pressure and temperature dependence of 35Cl nuclear quadrupole resonance (NQR) has been investigated in NaClO3 and Ba(ClO3)2·H2O. NQR frequencies are measured in the temperature range 77–300 K and up to 5 kbar pressure. The torsional frequency of the ClO3 pyramid and its variation with both pressure and temperature are evaluated from the NQR frequencies under the harmonic approximation. In general, the pressure effect on the internal motions is found to be less in Ba (ClO3)2·H2O compared to NaClO3. When the samples are cooled to 77 K the pressure coeffecient of NQR frequency becomes nearly zero in sodium chlorate, whereas it retains a value of 6 kHz kbar−1 in barium chlorate. This behaviour follows from the fact that at 77K, the torsional frequency in NaClO3 is unaffected by the application of pressure while it increases at the rate 12 cm−1 kbar−1 in Ba(ClO3)2·H2O.
Resumo:
Hypertension is one of the major risk factors for cardiovascular morbidity. The advantages of antihypertensive therapy have been clearly demonstrated, but only about 30% of hypertensive patients have their blood pressure (BP) controlled by such treatment. One of the reasons for this poor BP control may lie in the difficulty in predicting BP response to antihypertensive treatment. The average BP reduction achieved is similar for each drug in the main classes of antihypertensive agents, but there is a marked individual variation in BP responses to any given drug. The purpose of the present study was to examine BP response to four different antihypertensive monotherapies with regard to demographic characteristics, laboratory test results and common genetic polymorphisms. The subjects of the present study are participants in the pharmacogenetic GENRES Study. A total of 208 subjects completed the whole study protocol including four drug treatment periods of four weeks, separated by four-week placebo periods. The study drugs were amlodipine, bisoprolol, hydrochlorothiazide and losartan. Both office (OBP) and 24-hour ambulatory blood pressure (ABP) measurements were carried out. BP response to study drugs were related to basic clinical characteristics, pretreatment laboratory test results and common polymorphisms in genes coding for components of the renin-angiotensin system, alpha-adducin (ADD1), beta1-adrenergic receptor (ADRB1) and beta2-adrenergic receptor (ADRB2). Age was positively correlated with BP responses to amlodipine and with OBP and systolic ABP responses to hydrochlorothiazide, while body mass index was negatively correlated with ABP responses to amlodipine. Of the laboratory test results, plasma renin activity (PRA) correlated positively with BP responses to losartan, with ABP responses to bisoprolol, and negatively with ABP responses to hydrochlorothiazide. Uniquely to this study, it was found that serum total calcium level was negatively correlated with BP responses to amlodipine, whilst serum total cholesterol level was negatively correlated with ABP responses to amlodipine. There were no significant associations of angiotensin II type I receptor 1166A/C, angiotensin converting enzyme I/D, angiotensinogen Met235Thr, ADD1 Gly460Trp, ADRB1 Ser49Gly and Gly389Arg and ADRB2 Arg16Gly and Gln27Glu polymorphisms with BP responses to the study drugs. In conclusion, this study confirmed the relationship between pretreatment PRA levels and response to three classes of antihypertensive drugs. This study is the first to note a significant inverse relation between serum calcium level and responsiveness to a calcium channel blocker. However, this study could not replicate the observations that common polymorphisms in angiotensin II type I receptor, angiotensin converting enzyme, angiotensinogen, ADD1, ADRB1, or ADRB2 genes can predict BP response to antihypertensive drugs.
Resumo:
The equilibrium pressure of calcium corresponding to the reduction reaction 6CaO (s) + 2Al (l) half-arrow-right-over-half-arrow-left 3CaO.Al2O3 (s) + 3Ca (g) has been measured by Knudsen effusion - mass loss analysis in the temperature range 1190 - 1500 K. The measured vapour pressure can be expressed as a function of temperature by the relation: log p(Ca) (Pa) = -10,670/T + 9.267 The calcium generated is partially absorbed by aluminium to form an alloy. The equilibrium composition of the alloy at 1373 K was found to be 22 mol% Ca - 78 mol% Al. The measured vapour pressure is in good agreement with that computed from thermodynamic data.
Resumo:
The pressure dependence of critical parameters xc, Tc, and β have been analysed in four systems namely cyclohexane + acetic anhydride, n-heptane + acetic anhydride, methanol + n-heptane, and carbon disulphide + acetonitrile. The separation temperature was found to increase linearly with pressure the value of dTc/dP being 28 mK, 11 mK, 22 mK, and 25 mK respectively. These are in fair agreement with earlier measurements available for two systems. For the methanol + n-heptane system dTc/dP is apparently not consistent with the value predicted from the specific heat and thermal expansion data.Die Druckabhängigkeit der kritischen Parameter xc, Tc und β ist in den vier Systemen Cyclohexan + Essigsäureanhydrid, n-Heptan + Essigsäureanhydrid, Methanol + n-Heptan und Schwefelkohlenstoff + Acetonitril analysiert worden. Es wurde gefunden, daß die kritische Temperatur linear mit dem Druck ansteigt. Die Werte für dTc/dP betragen 28 mK, 11 mK, 22 mK und 25 mK. Sie sind in guter überein-stimmung mit früheren Messungen an zweien dieser Systeme. Für Methanol + n-Heptan stimmt der Wert für dT/dP offensichtlich nicht mit Werten, die mit Hilfe von Daten für die spezifische Wärme und die thermische Ausdehnung vorhergesagt wurden, überein.
Resumo:
Experimental studies on the measurement of pressure fields in the region of separating and reattaching flows behind several two-dimensional fore-bodies and one axisymmetric body are reported. In particular, extensive measurements of mean pressure, surface pressure fluctuation, and pressure fluctuation within the flow were made for a series of two-dimensional fore-body shapes consisting of triangular nose with varying included angle. The measurements from different bodies are compared and one of the important findings is that the maximum values of rms pressure fluctuation levels in the shear layer approaching reattachment are almost equal to the maximum value of the surface fluctuation levels.
Resumo:
The performance of a pressure transducer with meandering-path thin film strain gauges has been studied. Details of the procedure followed to prepare the thin film strain gauge system on the pressure transducer diaphragm are given. The effect of post-deposition heat treatment on the resistance of the sensing films of the strain gauges and the insulating base layers are discussed. The output of the pressure transducer was studied with various input pressures and excitation voltages. It was found that up to a maximum of 10 V bridge excitation the output was stable and repetitive. The maximum non-linearity and hysteresis observed are ±0.15%, ±0.16% and ±0.14% FSO (full-scale output) for 5, 7.5 and 10 V excitation respectively. Information on the output behaviour of the pressure transducer with temperature is also included.
Resumo:
A diaphragm-type pressure transducer with a sputtered platinum film strain gauge (sensing film) has been designed and fabricated. The various steps followed to prepare thin film strain gauges on the diaphragm are described. M-bond 450 adhesive (Measurements Group, USA) has been employed as the insulating layer. A detailed procedure to cure this layer is given. A d.c. sputtering method is employed to prepare the platinum films. This paper also includes details of the strain gauge pattern and its location on the diaphragm. A description of the output characteristics and overall behaviour of the platinum thin film pressure transducer is reported.