994 resultados para Posteroanterior motion test
Resumo:
INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.
Resumo:
Fundação para a Ciência e a Tecnologia (FCT) - PhD grant (SFRH/BD/62568/2009)
Resumo:
INTRODUCTION: Arenavirus hemorrhagic fever is a severe emerging disease. METHODS: Considering that the levels of antibodies against arenavirus in the Brazilian population are completely unknown, we have standardized an ELISA test for detecting IgG antibodies using a recombinant nucleoprotein from the Junin virus as the antigen. This protein was obtained by inserting the gene of the Junin virus nucleoprotein into the genome of Autographa californica nucleopolyhedrovirus, using the Bac-to-Bac baculovirus expression system. This recombinant baculovirus was used to infect S. frugiperda cells (SF9). RESULTS: The infection resulted in synthesis of high concentrations of recombinant protein. This protein was detected on 12.5% polyacrylamide gel and by means of Western blot. Using the standardized ELISA test, 343 samples from the population of Nova Xavantina were analyzed. We observed that 1.4% of the serum samples (five samples) presented antibody titers against arenavirus. CONCLUSIONS: These results show the population studied may present exposure to arenavirus infection.
Resumo:
INTRODUCTION: To evaluate physical capacity as determined by the six-minute walk test (6MWT) in patients with chronic heart failure due to Chagas' disease associated with systemic arterial hypertension (Chagas-SAH). METHODS: A total of 98 patients routinely followed at the Cardiomyopathy Outpatient Service were recruited. Of these, 60 (61%) were diagnosed with Chagas disease and 38 (39%) with Chagas-SAH. RESULTS: The distance walked during 6 min was 357.9 ±98 m for Chagas-SAH patients and 395.8 ± 121m for Chagas cardiomyopathy patients (p >0.05). In patients with Chagas-SAH, a negative correlation occurred between the 6MWT and the total score of the Minnesota Living with Heart Failure Questionnaire (r= -0.51; p=0.001). No other correlations were determined between 6MWT values and continuous variables in patients with Chagas-SAH. CONCLUSIONS: The results of the 6MWT in Chagas-SAH patients are similar to those verified in Chagas cardiomyopathy patients with chronic heart failure. Coexistence of SAH does not seem to affect the functional capacity of Chagas cardiomyopathy patients with chronic heart failure.
Resumo:
With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.
Resumo:
Since the invention of photography humans have been using images to capture, store and analyse the act that they are interested in. With the developments in this field, assisted by better computers, it is possible to use image processing technology as an accurate method of analysis and measurement. Image processing's principal qualities are flexibility, adaptability and the ability to easily and quickly process a large amount of information. Successful examples of applications can be seen in several areas of human life, such as biomedical, industry, surveillance, military and mapping. This is so true that there are several Nobel prizes related to imaging. The accurate measurement of deformations, displacements, strain fields and surface defects are challenging in many material tests in Civil Engineering because traditionally these measurements require complex and expensive equipment, plus time consuming calibration. Image processing can be an inexpensive and effective tool for load displacement measurements. Using an adequate image acquisition system and taking advantage of the computation power of modern computers it is possible to accurately measure very small displacements with high precision. On the market there are already several commercial software packages. However they are commercialized at high cost. In this work block-matching algorithms will be used in order to compare the results from image processing with the data obtained with physical transducers during laboratory load tests. In order to test the proposed solutions several load tests were carried out in partnership with researchers from the Civil Engineering Department at Universidade Nova de Lisboa (UNL).
Resumo:
INTRODUCTION: Mansonelliasis is caused by Mansonella ozzardi. It is widespread in the Amazon region, with a high prevalence. The common exam of thick blood smears stained with Giemsa shows low efficacy levels and has been an obstacle to diagnosing individuals with low blood parasitemia. METHODS: In order to increase diagnosis efficacy, the PCR technique was improved. RESULTS AND CONCLUSIONS: PCR demonstrated the best performance, with sensitivity and negative predictive values (NPV) of 100%, followed by blood filtration through membrane filters, which showed a sensitivity of 88.9% and a NPV of 84.6%, when compared to thick blood smears.
Resumo:
INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.
Resumo:
Proceedings of the 16th Annual Conference organized by the Insurance Law Association of Serbia and German Foundation for International Legal Co-Operation (IRZ), entitled "Insurance law, governance and transparency: basics of the legal certainty" Palic Serbia, 17-19 April 2015.
Resumo:
INTRODUCTION: Since 1970, lengthening of the rectosigmoid has been suspected to be a solitary manifestation of Chagas colopathy. METHODS: To test this hypothesis, opaque enema was administered on 210 seropositive and 63 seronegative patients, and radiographs in the anteroposterior and posteroanterior positions were examined blind to the serological and clinical findings. The distal colon was measured using a flexible ruler along the central axis of the image from the anus to the iliac crest. RESULTS: Dolichocolon was diagnosed in 31 (14.8%) seropositive and 3 (4.8%) seronegative patients. The mean length was 57.2 (±12.2)cm in seropositive patients and 52.1 (±8.8)cm in the seronegative patients (p = 0.000), that is, the distal colon in Chagas patients was, on average, 5.1cm longer. Seropositive female patients presented a mean length of 58.8 (±12.3)cm, and seronegative female patients presented 53.2 (±9.1)cm (p = 0.002). Seropositive male patients had a mean length of 55 (±11.6)cm, and seronegative male patients had 49.9 (±7.8)cm (p = 0.02). Among 191 patients without megacolon and suspected megacolon, the mean length was 56.3 (±11.6)cm in seropositive individuals and 52 (±8.8)cm in seronegative patients (p = 0.003). Among individuals with distal colon >70cm, there were 31 Chagas patients with mean length of 77.9 (±7.1)cm and three seronegative with 71.3 (±1.1)cm (p = 0.000). Among 179 with distal colon <70cm, seropositive individuals had a mean length of 53.6 (±8.8)cm, and seronegative patients had 51.2 (±7.8)cm (p = 0.059). Serological positive women had longer distal colon than men (p = 0.02), whereas the mean length were the same among seronegative individuals (p = 0.16). CONCLUSIONS: In endemic areas of Brazil Central, solitary dolichocolon is a radiological Chagas disease signal.
Resumo:
Introduction Dengue is prevalent in many tropical and sub-tropical regions. The clinical diagnosis of dengue is still complex, and not much data are available. This work aimed at assessing the diagnostic accuracy of the tourniquet test in patients with suspected dengue infection and its positivity in different classifications of this disease as reported to the Information System for Notifiable Disease in Belo Horizonte, State of Minas Gerais, Brazil between 2001 and 2006. Methods Cross-section analysis of the diagnostic accuracy of the tourniquet test for dengue, using IgM-anti-DENV ELISA as a gold standard. Results We selected 9,836 suspected cases, of which 41.1% were confirmed to be dengue. Classic dengue was present in 95.8%, dengue with complications in 2.5% and dengue hemorrhagic fever in 1.7%. The tourniquet test was positive in 16.9% of classic dengue cases, 61.7% of dengue cases with complications and 82.9% of cases of dengue hemorrhagic fever. The sensitivity and specificity of the tourniquet test were 19.1% and 86.4%, respectively. Conclusions A positive tourniquet test can be a valuable tool to support diagnosis of dengue where laboratory tests are not available. However, the absence of a positive test should not be read as the absence of infection. In addition, the tourniquet test was demonstrated to be an indicator of dengue severity.
Resumo:
The catastrophic disruption in the USA financial system in the wake of the financial crisis prompted the Federal Reserve to launch a Quantitative Easing (QE) programme in late 2008. In line with Pesaran and Smith (2014), I use a policy effectiveness test to assess whether this massive asset purchase programme was effective in stimulating the economic activity in the USA. Specifically, I employ an Autoregressive Distributed Lag Model (ARDL), in order to obtain a counterfactual for the USA real GDP growth rate. Using data from 1983Q1 to 2009Q4, the results show that the beneficial effects of QE appear to be weak and rather short-lived. The null hypothesis of policy ineffectiveness is not rejected, which suggests that QE did not have a meaningful impact on output growth.
Resumo:
Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.
Resumo:
Introduction. The genera Enterococcus, Staphylococcus and Streptococcus are recognized as important Gram-positive human pathogens. The aim of this study was to evaluate the performance of Vitek 2 in identifying Gram-positive cocci and their antimicrobial susceptibilities. Methods. One hundred four isolates were analyzed to determine the accuracy of the automated system for identifying the bacteria and their susceptibility to oxacillin and vancomycin. Results. The system correctly identified 77.9% and 97.1% of the isolates at the species and genus levels, respectively. Additionally, 81.8% of the Vitek 2 results agreed with the known antimicrobial susceptibility profiles. Conclusion. Vitek 2 correctly identified the commonly isolated strains; however, the limitations of the method may lead to ambiguous findings.
Resumo:
Introduction Despite the known importance of Clostridium difficile as a nosocomial pathogen, few studies regarding Clostridium difficile infection (CDI) in Brazil have been conducted. To date, the diagnostic tests that are available on the Brazilian market for the diagnosis of CDI have not been evaluated. The aim of this study was to compare the performances of four commercial methods for the diagnosis of CDI in patients from a university hospital in Brazil. Methods Three enzyme immunoassays (EIAs) and one nucleic acid amplification test (NAAT) were evaluated against a cytotoxicity assay (CTA) and toxigenic culture (TC). Stool samples from 92 patients with suspected CDI were used in this study. Results Twenty-five (27.2%) of 92 samples were positive according to the CTA, and 23 (25%) were positive according to the TC. All EIAs and the NAAT test demonstrated sensitivities between 59 and 68% and specificities greater than 91%. Conclusions All four methods exhibited low sensitivities for the diagnosis of CDI, which could lead to a large number of false-negative results, an increased risk of cross-infection to other patients, and overtreatment with empirical antibiotics.