960 resultados para Peri-implant bones


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT : Background : The aim of this study was to evaluate the midterm biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. Methods : Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. [OP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. Results : For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. Conclusions : The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El llibre editat pel Dr. Ripoll Perelló s'emmarca en un deIs aspectes més destacats de la seva producció bibliografica, la de les recopilacions documentals, necrologiques i altres aspectes relacionats amb la historia de la prehistoria. Vull deixar clar que faig aquesta constatació en termes d' elogi i d' admiració, ja que les aportacions del Dr. Ripoll Perelló són molt valuoses per entendre moltes coses que continuen vigents en la prehistoria mundial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El dos de noviembre de 1935 se inauguró el Museo Arqueológico de Barcelona, sito en el antiguo edificio del Palacio de las Artes Gráficas construido para la Exposición Universal de 1929. Era el resultado de una ardua trayectoria iniciada por Pere Bosch Gimpera en 1916 por la que intentaba aplicar en Cataluña el esquema tripartito de protección del patrimonio histórico-artístico y arqueológico que había aprendido durante su estancia en Alemania como becario de la JAE entre 1911 y 1914, basado en la suma de tres conceptos: investigación, docencia y difusión. El nuevo equipamiento nacía bajo los auspicios de la Generalitat republicana y tras haber superado múltiples obstáculos derivados de la concepción clasista y winckelmaniana que ejercían tanto los responsables del museo del parque de la Ciudadela, como los integrantes de la Junta de Museos de Barcelona, más preocupados por el goce artístico de las obras de arte que por su inclusión como documentos en el ámbito del estudio de los procesos históricos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Primary bone sarcomas around the ankle are rare. Due to the proximity of neurovascular structures and limited soft tissue reserves, limb salvage is often not possible. Case report: A 19 yo male presented with pain and a progressive swelling of his ankle. X-rays revealed cortical erosions and an extensive periosteal reaction (sunburst) of the distal fibula. MRI showed a large mass of the fibula invading adjacent soft tissue. The lesion appeared close to the ankle joint, but with the articular cartilage as a barrier and without joint effusion. Core-needle biopsy revealed a high-grade chondroblastic osteosarcoma. No metastases were detected. After presentation at our multidisciplinary sarcoma board, the patient was subjected to neo-adjuvant chemotherapy (AOST 03-331). Without any sign of intra-articular contamination of the ankle joint, surgical treatment consisted of wide resection of the lateral malleolus including a large skin patch, the distal third of the fibula, the lateral surfaces of the tibia and talus as well as the insertion of the lateral ligament on the calcaneus. The distal parts of the anterior, peroneal, and posterior muscular compartments were resected en bloc with the tumor. The defect was reconstructed with tibio-talar and talo-calcanear fusion, bony allograft and a plate. Soft-tissue coverage was achieved with a free fascio-cutaneous flap from the controlateral thigh. Histological analysis revealed clear margins and 50% of tumor necrosis. The oncologic treatment was completed with adjuvant chemotherapy. Conclusion: Wide resection and reconstruction of the lateral malleolus is technically demanding but possible in selected cases. Despite some important functional loss, limb salvage is superior to an amputation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of patients suffering from cardiovascular disease, especially coronary artery disease (CAD), are treated with aspirin and/or clopidogrel for the prevention of major adverse events. Unfortunately, there are no specific, widely accepted recommendations for the perioperative management of patients receiving antiplatelet therapy. Therefore, members of the Perioperative Haemostasis Group of the Society on Thrombosis and Haemostasis Research (GTH), the Perioperative Coagulation Group of the Austrian Society for Anesthesiology, Reanimation and Intensive Care (ÖGARI) and the Working Group Thrombosis of the European Society of Cardiology (ESC) have created this consensus position paper to provide clear recommendations on the perioperative use of anti-platelet agents (specifically with semi-urgent and urgent surgery), strongly supporting a multidisciplinary approach to optimize the treatment of individual patients with coronary artery disease who need major cardiac and non-cardiac surgery. With planned surgery, drug eluting stents (DES) should not be used unless surgery can be delayed for ≥12 months after DES implantation. If surgery cannot be delayed, surgical revascularisation, bare-metal stents or pure balloon angioplasty should be considered. During ongoing antiplatelet therapy, elective surgery should be delayed for the recommended duration of treatment. In patients with semi-urgent surgery, the decision to prematurely stop one or both antiplatelet agents (at least 5 days pre-operatively) has to be taken after multidisciplinary consultation, evaluating the individual thrombotic and bleeding risk. Urgently needed surgery has to take place under full antiplatelet therapy despite the increased bleeding risk. A multidisciplinary approach for optimal antithrombotic and haemostatic patient management is thus mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare earth elements (REE), while not essential for the physiologic functions of animals, are ingested and incorporated in ppb concentrations in bones and teeth. Nd isotope compositions of modern bones of animals from isotopically distinct habitats demonstrate that the (143)Nd/(144)Nd of the apatite can be used as a fingerprint for bedrock geology or ambient water mass. This potentially allows the provenance and migration of extant vertebrates to be traced, similar to the use of Sr isotopes. Although REE may be enriched by up to 5 orders of magnitude during diagenesis and recrystallization of bone apatite, in vivo (143)Nd/(144)Nd may be preserved in the inner cortex of fossil bones or enamel. However, tracking the provenance of ancient or extinct vertebrates is possible only for well-preserved archeological and paleontological skeletal remains with in vivo-like Nd contents at the ppb-level. Intra-bone and -tooth REE analysis can be used to screen for appropriate areas. Large intra-bone Nd concentration gradients of 10(1)-10(3) are often measured. Nd concentrations in the inner bone cortex increase over timescales of millions of years, while bone rims may be enriched over millenial timescales. Nevertheless, epsilon(Nd) values are often similar within one epsilon(Nd) unit within a single bone. Larger intra-bone differences in specimens may either reflect a partial preservation of in vivo values or changing epsilon(Nd) values of the diagenetic fluid during fossilization. However, most fossil specimens and the outer rims of bones will record taphonomic (143)Nd/(144)Nd incorporated post mortem during diagenesis. Unlike REE patterns, (143)Nd/(144)Nd are not biased by fractionation processes during REE-uptake into the apatite crystal lattice, hence the epsilon(Nd) value is an important tracer for taphonomy and reworking. Bones and teeth from autochthonous fossil assemblages have small variations of +/- 1 epsilon(Nd) unit only. In contrast, fossil bones and teeth from over 20 different marine and terrestrial fossil sites have a total range of epsilon(Nd) values from -13.0 to 4.9 (n = 80), often matching the composition of the embedding sediment. This implies that the surrounding sediment is the source of Nd in the fossil bones and that the specimens of this study seem not to have been reworked. Differences in epsilon(Nd) values between skeletal remains and embedding sediment may either indicate reworking of fossils and/or a REE-uptake from a diagenetic fluid with non-sediment derived epsilon(Nd) values. The latter often applies to fossil shark teeth, which may preserve paleo-seawater values. Complementary to epsilon(Nd) values, (87)Sr/(86)Sr can help to further constrain the fossil provenance and reworking. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances in implant design, surgical technique, peri-operative antimicrobial prophylaxis and laminar airflow operating room environment have made total joint arthroplasty one of the most successful surgical procedures of all times. Orthopaedic implants, however, remain prone to microbial contamination resulting in persistent risk of implant-associated infection. Treatment of infections associated with orthopaedic devices usually requires appropriate surgical intervention combined with a prolonged antimicrobial therapy. The choice of the best possible treatment regimen depends on duration and pathogenesis of infection, stability of the implant, antimicrobial susceptibility of the pathogen and condition of the surrounding soft tissue. In addition towell known diagnostic procedures new promising tools for rapid and correct microbial diagnosis are being developed as correct diagnosis of the responsible micro-organism and this is paramount for successful treatment of prosthetic joint infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To study the efficacy and safety of a new intravitreal implant (sustained release of dexamethasone, Ozurdex®) recently approved in Switzerland for the treatment of macular edema secondary to retinal vein occlusion in a clinical setting.Patients and Methods: Prospective non-consecutive study of patients with macular edema secondary to central retinal vein occlusion or branch retinal vein occlusion treated with implant of dexamethasone 0.7 mg. Follow-up visits were performed at day 1, week 1 and monthly thereafter. ETDRS best corrected visual acuity, Goldmann tonometry and macular thickness on SD-OCT were registered. Retreatment was carried out on a pro re nata basis starting from month 3.Results: Fifteen eyes of 15 patients were included (8 branch retinal vein occlusions, 7 central retinal vein occlusions). 33 % of the patients achieved 3 lines or more of vision gain. The central retinal vein occlusion subgroup showed a mean decline in visual acuity at month 3. A reduction of 36 % of macular edema was already observed at day 1. All maculae were dry at month 1. The mean time of recurrence of macular edema for both groups was 4.6 months. A similar reduction of macular edema was obtained after a second implantation. An intraocular pressure increase of ≥ 20 % was observed after the first implantation in 53 % of patients.Conclusion: Our study showed efficacy and safety of intravitreal dexamethasone implant in the treatment of macular edema due to retinal vein occlusion. Anatomical efficacy was observed at day 1 but seems to have shorter effect than previously published data. No serious side effects were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’escola bressol és el primer centre educatiu on els infants tenen accés a l’era digital després de l’entorn familiar que és el primer que reben després del seu naixement. Aquests centres educatius també han de donar resposta a la societat digital que hi ha actualment per tal d’aconseguir un desenvolupament integral de l’infant. Per realitzar aquesta integració de les Tecnologies de la Informació i la Comunicació (TIC) al centre és important una bona formació per part dels docents i tenir clar quins són els elements que fan una bona pràctica TIC. En el present treball final de grau s’aprofundeix en les bones pràctiques educatives en l’ús de les TIC i, posteriorment, es realitza una proposta de transferència de les mateixes a una escola de nova creació.