963 resultados para Neutron irradiation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degradation of the antibiotic tetracycline (TC) by the photo-Fenton process was evaluated under black-light and solar irradiation. The influences of iron source (Fe(NO3)(3) or ferrioxalate), hydrogen peroxide and matrix (pure water, surface water and a sewage treatment plant effluent-STP) were evaluated. Under black-light irradiation, TC degradation was favored in the presence of Fe(NO3)(3), achieving total degradation after 1 min irradiation, while under solar light the use of ferrioxalate favors the degradation. Nevertheless, no significant difference in total organic carbon removal was observed between these two iron sources, achieving a residual concentration of around 5 mg L-1 under black-light and 2 mg L-1 under solar light irradiation. No decrease of the degradation efficiency relative to pure water was observed when TC was irradiated in a sample of surface water, under either black-light or solar irradiation. However, lower efficiency was obtained under black-light when TC was present in a sample of STP effluent, indicating the interference of the constituents of this sample on the overall efficiency of the process. on the other hand, under solar irradiation in the presence of ferrioxalate, no influence of the matrix was observed, even in the sample of STP effluent, achieving total degradation of TC in 1.5 min. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work films were produced by the plasma enhanced chemical vapor deposition (PECVD) of titanium tetraisopropoxide-oxygen-helium mixtures and irradiated with 150 keV singly-charged nitrogen ions (N(+)) at fluences, phi, between 10(14) and 10(16) cm(-2). Irradiation resulted in compaction, which reached about 40% (measured via the film thickness) at the highest fluence. Infrared reflection-absorption spectroscopy (IRRAS) revealed the presence of Ti-O bonds in all films. Both O-H and C-H groups were present in the as-deposited films, but the density of each of these decreased with increasing phi and was absent at high phi, indicating a loss of hydrogen. X-ray photoelectron spectroscopy (XPS) analyses revealed an increase in the C to Ti atomic ratio as phi increased, while the O to Ti ratio hardly altered, remaining at around 2.8. The optical gap of the films, derived from data obtained by ultraviolet-visible spectroscopy (UVS), remained at about 3.6 eV for all fluences except the highest, for which an abrupt fall to around 1.0 eV was observed. For the irradiated films, the electrical conductivity, measured using the two-point method, showed a systematic increase with increasing phi. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of ion irradiation on fluorinated plasma polymer films are investigated using profilometry, surface contact-angle measurements, infrared reflection absorption spectroscopy (IRRAS) and X-ray photoelectron spectroscopy (XPS). Remarkably, helium plasma immersion ion implantation (PIII) of several amorphous hydrogenated fluorinated plasma polymers deposited from C(2)H(2)-SF(6), C(6)H(6)-SF(6) or C(6)F(6) produces film compactions of up to 40%, and modifies the surface energy in the 35 to 65 dyn cm(-1) range. As revealed by IRRAS and XPS, the films contain C-H, C-C, C=C, C=O, O-H and C-F groups. XPS spectra confirm the presence of N (typically similar to 5%). The films produced from SF(6)-containing plasmas also contain S. For irradiation times of 80 min, the film carbon content is increased, and the fluorine content is greatly reduced, by factors of about 3 to 15, depending on the initial film composition. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alcohols and acids can be switched to produce ethers or esters by varying the alcohol to catalyst mol ratio, in a new etherification and esterification method using NbCl5/Al2O3 catalyst under "solvent free" conditions and promoted by MW (microwave) irradiation. A "two sites" mechanism for the reaction is proposed, in an attempt to clarify the tendency of the catalyst to be dependent on the alcohol alone during the esterification process. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface).Study design. Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er: YAG laser -1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd: YAG laser -2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn's test.Results. SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. on the other hand, apicectomies carried out with Er: YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd: YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd: YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas.Conclusions. There were no differences in terms of cut quality between the use of burs and Er: YAG laser or between the 2 surfaces (apical and buccal) treated with Nd: YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e77-e82)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article a new technique for thermal neutron detection using pyroelectric ceramics is described. The detector system is basically constituted of a PZT (lead zirconate titanate) ceramic attached to an uranium disk. The energy released in the uranium fission gives rise to an electrical signal in the detector which is amplified by a lock-in system. The neutron beam impinging on the uranium disk was modulated with a cadmium chopper. Thermal neutron fluxes within the interval of 103 to 106 n/cm2 s have been detected using a U3O8 pellet with 20% enrichment in 235U. © 1992.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the Walecka model to investigate the influence of the charge symmetry breaking ρ0-ω mixing interaction on the neutron-proton self-energy difference in nuclear matter. Using 2mρ〈ρ0|H|ω〉 = -4500 MeV2, and employing the Dirac-Hartree-Fock approximation, we find that the neutron-proton self-energy difference is a decreasing function of the nuclear matter density, and that it has a value of the order of 700 keV at the normal density. The results indicate that the Nolen-Schiffer anomaly might be explained by means of relativistic nuclear models in a similar way as it is explained by means of non-relativistic models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin uranium films built on muscovite mica basis and obsidian samples having known ages were irradiated with thermal neutrons at the IPEN/CNEN reactor, São Paulo. Comparing thin film performance with the obsidian one, it was observed that the latter feel a greater neutron fluence. Nominal fluences at the used facility are in agreement with the results obtained analysing the obsidian samples. A probable hypothesis to explain this disagreement, namely, the uranium loss from the thin films, was ruled out. © 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the ferromagnetic screening for the decay of the X-ray neutron star magnetic field in the binary accretion phase, the phase transition of ferromagnetic materials in the crust of neutron star induces the ferromagnetic screening saturation of the accreted crust, which results in the minimum surface magnetic field of the accreting neutron star, about 108 G, if the accreted matter has completely replaced the crust mass of the neutron star. The magnetic field evolution versus accreted mass is given as Bs ∝ ΔM-0.9, and the obtained magnetic field versus spin period relation is consistent with the distribution of the binary X-ray sources and recycled pulsars. The further thermal effect on the magnetic evolution is also studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the equation of state for neutron matter using the Walecka model including quantum corrections for baryons and sigma mesons through a realignment of the vacuum. We next use this equation of state to calculate the radius, mass, and other properties of rotating neutron stars.