882 resultados para NETTRA-E2-FIFO (Computer program)
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study evaluated the effect of ultrasonic vibration on the tensile strength required to remove intraradicular post cemented with different materials. Bovine teeth were selected, and 7 mm of the cervical root canals were prepared to size 5 Largo drill, the posts were cemented with zinc phosphate, Enforce (resin) or Rely X (glass ionomer). The specimens were divided into six groups (n = 10), according to the following procedures: GI-cementation with zinc phosphate associated with traction force; GII-cementation with zinc phosphate associated with ultrasonic activation and traction force; G111-cementation with Enforce associated with traction force; GIV-cementation with Enforce associated with ultrasonic activation and traction force; GV-cementation with Rely X associated with traction force; and GVI-cementation with Rely X associated with ultrasonic activation and traction force. The tensile test was conducted using the electromechanical testing machine, the force was determined by a specialized computer program and ultrasonic activation using the Jet Sonic Four Plus (Gnatus) device in 10P. Concerning to average ranking, GI showed statistically significant difference in comparison with GII and GVI (p < 0.05); there was no statistical difference in GIII and GIV when compared to other groups (p > 0.05). The ultrasound favored the intraradicular post traction regardless of the employed cement in greater or lesser extent. The post removal is a routine practice in the dental office, therefore, new solutions and better alternatives are need to the practitioner. We did not find in the literature many articles referring to this practice. Thus, the results from this study are relevant in the case planning and to promote more treatment options.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Low-intensity laser has been used as a physical agent in various fields of medical sciences such as bone and tissue repair. Meanwhile little is known about its effects in adverse conditions such as abolition of load and osteopenic. With the assumption that the laser Ga-Al-As accelerates the process of bone consolidation, goal of this study was to evaluate bone mineral density (BMD) in incomplete transverse osteotomies of tibia in adult rats, treated with low power laser therapy in three different groups: G1 (n = 10), reference 15 days; G2 (n=10), suspended by the tail and, accordingly, treated with laser for 12 days; G3 (n = 10), suspended by the tail by 36 days and that after 21 days, there was laser treatment for 12 days. The right tibia treated with laser and left served as control. The laser was used to Ga-Al-As, DMC - Flash Lase® III, with wavelength 830nm, 100 mW, 4J, 140 J / cm ², 40s of application in 12 sessions. It was used densitometer-Lunar DPX®, with computer program for "small animals", and the analysis of BMD was made in the bone throughout the region and the osteotomy. The results showed no efficacy of laser therapy in the process of bone repair, both in animals of group 1, as in group 2 and 3. It follows that either the low-power laser was not an effective performance or the effects of laser therapy is not only manifested at the site of irradiation as well as the systemic level.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Matemática em Rede Nacional - IBILCE
Resumo:
This study aims to develop a computer program based on VBA programming language, using Microsoft Excel, for designing pumping systems of water. The program allows the user to determine the economical diameter, using the equation of Bresse, for a given installation, since the geometric elevation, the material of the tube, the accessories along the line and the volumetric flow are known. In addition, the program estimates the total annual cost of the installation for three different diameters, in order to compare which diameter is more advantageous from an economical perspective. The program interface is designed to be simple and intuitive with the intention of being didactic and offering to engineering students an advantageous tool to analyze this type of project. Microsoft Excel was chosen for this work because is present in virtually all personal computer, and is an indispensable tool for educational purposes
Resumo:
In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
This study aims to develop a computer program based on VBA programming language, using Microsoft Excel, for designing pumping systems of water. The program allows the user to determine the economical diameter, using the equation of Bresse, for a given installation, since the geometric elevation, the material of the tube, the accessories along the line and the volumetric flow are known. In addition, the program estimates the total annual cost of the installation for three different diameters, in order to compare which diameter is more advantageous from an economical perspective. The program interface is designed to be simple and intuitive with the intention of being didactic and offering to engineering students an advantageous tool to analyze this type of project. Microsoft Excel was chosen for this work because is present in virtually all personal computer, and is an indispensable tool for educational purposes
Resumo:
In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Background: Polycystic ovary syndrome (PCOS) is an endocrine disorder associated with metabolic dysfunction and changes in cardiovascular risk markers, and using oral contraceptives (OCs) may exert a further negative effect on these alterations in patients with PCOS. Thus, the primary objective of this study was to assess the effects on arterial function and structure of an OC containing chlormadinone acetate (2 mg) and ethinylestradiol (30 mcg), alone or combined with spironolactone (OC+SPL), in patients with PCOS. Study Design: This was a randomized, controlled clinical trial. Fifty women with PCOS between 18 and 35 years of age were randomized by a computer program to use OC or OC+SPL. Brachial artery flow-mediated vasodilation, carotid intima-media thickness and the carotid artery stiffness index were evaluated at baseline and after 6 and 12 months. Serum markers for cardiovascular disease were also analyzed. The intragroup data were analyzed using analysis of variance with Tukey's post hoc test. A multivariate linear regression model was used to analyze the intergroup data. Results: At 12 months, the increase in mean total cholesterol levels was greater in the OC+SPL group than in the OC group (27% vs. 13%, respectively; p=.02). The increase in mean sex hormone-binding globulin levels was greater in the OC group than in the OC+SPL group (424% vs. 364%, respectively; p=.01). No statistically significant differences between the groups were found for any of the other variables. Conclusion: The addition of spironolactone to an OC containing chlormadinone acetate and ethinylestradiol conferred no cardiovascular risk-marker advantages in young women with PCOS. (C) 2012 Elsevier Inc. All rights reserved.