Influence of light intensity and curing cycle on microleakage of Class V composite resin restorations


Autoria(s): SANTOS, Maria Jacinta Moraes Coelho; SOUZA JUNIOR, Mario Honorato Silva e; SANTOS JÚNIOR, Gildo Coelho; EL-MOWAFY, Omar; CAVALCANTI, Ana Paula Chedid; NEME, Carla Farah
Data(s)

21/10/2015

21/10/2015

01/06/2005

Resumo

O objetivo deste estudo foi determinar o efeito da polimerização gradual, mediante a utilização de aparelhos de Quartzo-Tungustênio-Halógena (QTH) e Arco de Plasma de Xenônio (PAC), no selamento marginal de restaurações classe V em resina composta com margens localizadas em dentina. Setenta e cinco incisivos bovinos receberam preparos de cavidades classe V, na raiz, com o intuito de situar as margens cavitárias em dentina. Os dentes foram divididos em cinco grupos de acordo com o método de fotoativação. As cavidades, depois de condicionadas, foram tratadas com o sistema adesivo Single Bond (3M Dental) e restauradas com a resina composta Z100 (3M Dental) pela técnica incremental. A fotoativação foi realizada para cada grupo como descrito a seguir: Grupo I: PAC pelo método de fotoativação constante: 1600mW/cm<sup>2</sup> – 3s; Grupo II: PAC pelo método de fotoativação por passos (800mW/cm<sup>2</sup> – 2s, subindo automaticamente para 1600mW/cm<sup>2</sup> – 4s); Grupo III: QTH pelo método de fotoativação constante: 400 mW/cm<sup>2</sup> – 40s; Grupo IV: QTH pelo método de fotoativação em rampa: 100 a 600 mW/cm<sup>2</sup> – 15s, permanecendo a 600mW/cm<sup>2</sup> por mais 25s; Grupo V: QTH pelo método de fotoativação por pulso: 200 mW/cm<sup>2</sup> – 3s, tempo de espera de 3min.e a seguir 600mW/cm<sup>2</sup> – 30s. Os dentes foram armazenados em água destilada a 37ºC por 30 dias e então submetidos à ciclagem térmica, por 500 ciclos à 5 ºC e 55 ºC. Os ápices dos dentes foram selados com resina composta e os dentes foram cobertos com duas camadas de esmalte para unha, antes da sua imersão em fucsina básica a 0,5%. Os dentes foram seccionados e os cortes foram escaneados para avaliação da área infiltrada por corante por um programa de computador (Image Tools). Os cortes foram também visualizados com lupa para a determinação do grau de penetração do corante na interface dente-restauração por escores. Diferenças estatisticamente significantes foram observadas entre os grupos quanto ao grau e à área de penetração de corante (p < 0,05). Os grupos I e II apresentaram valores significantemente mais altos de infiltração e penetração do corante que os grupos III, IV e V. Em conclusão, o uso da fonte de PAC, no modo constante e por passos, resultou em valores significantemente maiores de infiltração marginal quando comparados com a intensidade de luz média emitida pelos aparelhos de QTH. Os métodos de fotoativação por pulso, rampa e continuo com a fonte de QTH resultaram num grau similar de microinfiltração.

ABSTRACT: The aim of this study was to determine the effect of a softstart polymerization method from Quartz-Tungsten-Halogen (QTH) and Plasma Arc (PAC) curing units on microleakage of Class V composite resin restorations with dentin cavosurface margins. Seventy-five bovine incisors received standardized class V cavities in all dentin margins. Teeth were divided into 5 equal groups according to the curing cycle. The cavities were incrementally restored with a composite resin (Single Bond/Z-100, 3M). Light curing was applied as follows: Group I: PAC light continuous-cycle curing at 1600 mW/cm<sup>2</sup> for 3s; Group II: PAC light step-cycle curing (2s at 800 mW/cm<sup>2</sup> then 4s at 1600 mW/cm<sup>2</sup>); Group III: QTH light continuous-cycle curing at 400 mW/cm<sup>2</sup> for 40s; Group IV: QTH light ramp-cycle curing (from 100 to 600 mW/cm<sup>2</sup> in 15s followed by 25s at 600 mW/cm<sup>2</sup>); Group V: QTH light pulse-delay curing (200 mW/cm<sup>2</sup> for 3s followed by 3 min delay then 600 mW/cm<sup>2</sup> for 30s). Teeth were stored in distilled water at 37ºC for 30 days and then subjected to thermocycling for 500 cycles at 5 and 55ºC. Root apices were sealed and teeth coated with nail varnish before they were immersed in 0.5% fuchsine red dye solution. Teeth were then sectioned and slices were scanned with a computer scanner to determine the area of dye leakage using a computer program (Image Tools). Images of tooth slices were also visually examined under magnification and dye penetration along the tooth/restoration interface was scored. Significant differences in the degree of dye penetration and leakage were detected between groups (p<.05). Groups I and II had significantly higher values of dye penetration and leakage than groups III, IV and V. In conclusion, the use of PAC light curing in a continuous or step cycle modes resulted in increased microleakage of Class V resin composite restorations compared with medium intensity QTH light curing. Pulse, ramp and continuous-cycle curing modes with QTH light resulted in similar degrees of microleakage.

Identificador

SANTOS, Maria Jacinta Moraes Coelho et al. Influence of light intensity and curing cycle on microleakage of Class V composite resin restorations. Journal of Applied Oral Science, Bauru, v. 13, n. 2, p. 193-197, jun. 2005. Disponível em: <http://www.scielo.br/pdf/jaos/v13n2/a19v13n2.pdf>. Acesso em: 21 out. 2015. <http://dx.doi.org/10.1590/S1678-77572005000200019>.

1678-7765

http://repositorio.ufpa.br/jspui/handle/2011/6968

Idioma(s)

eng

Palavras-Chave #Resinas compostas #Infiltração dentária #Polimerização #Unidades fotopolimerizadoras
Tipo

article