844 resultados para Legal standard
Resumo:
The limited armamentarium of active and oral antifungal drugs against emerging non-Aspergillus molds is of particular concern. Current antifungal agents and the new orally available beta-1,3-d-glucan synthase inhibitor SCY-078 were tested in vitro against 135 clinical non-Aspergillus mold isolates. Akin to echinocandins, SCY-078 showed no or poor activity against Mucoromycotina and Fusarium spp. However, SCY-078 was highly active against Paecilomyces variotii and was the only compound displaying some activity against notoriously panresistant Scedosporium prolificans.
Resumo:
AIM: The aim of our study was to compare traumatic injuries observed after cardiopulmonary resuscitation (CPR) by means of standard (manual) or assisted (mechanical) chest compression by Lund University Cardiopulmonary Assist System, 2nd generation (LUCAS?2) device. METHODS: A retrospective study was conducted including cases from 2011 to 2013, analysing consecutive autopsy reports in two groups of patients who underwent medicolegal autopsy after unsuccessful CPR. We focused on traumatic injuries from dermal to internal trauma, collecting data according to a standardised protocol. RESULTS: The study group was comprised of 26 cases, while 32 cases were included in the control group. Cardiopulmonary resuscitation performed by LUCAS?2 was longer than manual CPR performed in control cases (study group: mean duration 51.5 min; controls 29.4 min; p = 0.004). Anterior chest lesions (from bruises to abrasions) were described in 18/26 patients in the LUCAS?2 group and in 6/32 of the control group. A mean of 6.6 rib fractures per case was observed in the LUCAS?2 group, but this was only 3.1 in the control group (p = 0.007). Rib fractures were less frequently observed in younger patients. The frequency of sternal factures was similar in both groups. A few trauma injuries to internal organs (mainly cardiac, pulmonary and hepatic bruises), and some petechiae (study 46 %; control 41 %; p = 0.79) were recorded in both groups. CONCLUSION: LUCAS?2-CPR is associated with more rib fractures than standard CPR. Typical round concentric skin lesions were observed in cases of mechanical reanimation. No life-threatening injuries were reported. Petechiae were common findings.
Resumo:
Biocuration has become a cornerstone for analyses in biology, and to meet needs, the amount of annotations has considerably grown in recent years. However, the reliability of these annotations varies; it has thus become necessary to be able to assess the confidence in annotations. Although several resources already provide confidence information about the annotations that they produce, a standard way of providing such information has yet to be defined. This lack of standardization undermines the propagation of knowledge across resources, as well as the credibility of results from high-throughput analyses. Seeded at a workshop during the Biocuration 2012 conference, a working group has been created to address this problem. We present here the elements that were identified as essential for assessing confidence in annotations, as well as a draft ontology--the Confidence Information Ontology--to illustrate how the problems identified could be addressed. We hope that this effort will provide a home for discussing this major issue among the biocuration community. Tracker URL: https://github.com/BgeeDB/confidence-information-ontology Ontology URL: https://raw.githubusercontent.com/BgeeDB/confidence-information-ontology/master/src/ontology/cio-simple.obo
Resumo:
Accurate prediction of mortality following burns is useful as an audit tool, and for providing treatment plan and resource allocation criteria. Common burn formulae (Ryan Score, Abbreviated Burn Severity Index (ABSI), classic and revised Baux) have not been compared with the standard Acute Physiology and Chronic Health Evaluation II (APACHEII) or re-validated in a severely (≥20% total burn surface area) burned population. Furthermore, the revised Baux (R-Baux) has been externally validated thoroughly only once and the pediatric Baux (P-Baux) has yet to be. Using 522 severely burned patients, we show that burn formulae (ABSI, Baux, revised Baux) outperform APACHEII among adults (AUROC increase p<0.001 adults; p>0.5 children). The Ryan Score performs well especially among the most at-risk populations (estimated mortality [90% CI] original versus current study: 33% [26-41%] versus 30.18% [24.25-36.86%] for Ryan Score 2; 87% [78-93%] versus 66.48% [51.31-78.87%] for Ryan Score 3). The R-Baux shows accurate discrimination (AUROC 0.908 [0.869-0.947]) and is well-calibrated. However, the ABSI and P-Baux, although showing high measures of discrimination (AUROC 0.826 [0.737-0.916] and 0.848 [0.758-0.938]) in children), exceedingly overestimates mortality, indicating poor calibration. We highlight challenges in designing and employing scores that are applicable to a wide range of populations.
Resumo:
BACKGROUND & AIMS: The standard liver volume (SLV) is widely used in liver surgery, especially for living donor liver transplantation (LDLT). All the reported formulas for SLV use body surface area or body weight, which can be influenced strongly by the general condition of the patient. METHODS: We analyzed the liver volumes of 180 Japanese donor candidates and 160 Swiss patients with normal livers to develop a new formula. The dataset was randomly divided into two subsets, the test and validation sample, stratified by race. The new formula was validated using 50 LDLT recipients. RESULTS: Without using body weight-related variables, age, thoracic width measured using computed tomography, and race independently predicted the total liver volume (TLV). A new formula: 203.3-(3.61×age)+(58.7×thoracic width)-(463.7×race [1=Asian, 0=Caucasian]), most accurately predicted the TLV in the validation dataset as compared with any other formulas. The graft volume for LDLT was correlated with the postoperative prothrombin time, and the graft volume/SLV ratio calculated using the new formula was significantly better correlated with the postoperative prothrombin time than the graft volume/SLV ratio calculated using the other formulas or the graft volume/body weight ratio. CONCLUSIONS: The new formula derived using the age, thoracic width and race predicted both the TLV in the healthy patient group and the SLV in LDLT recipients more accurately than any other previously reported formulas.
Resumo:
OBJETIVO: Este trabalho aborda as conseqüências de laudos necroscópicos incompletos de baleados, nos casos em que não foi possível o uso de recursos radiológicos para localizar os projéteis de arma de fogo. MATERIAIS E MÉTODOS: Foram analisados 8.185 laudos necroscópicos do Instituto Médico-Legal Afrânio Peixoto, Rio de Janeiro, RJ, referentes à demanda total de cadáveres no período de 1º de janeiro a 31 de dezembro de 2001, dos quais 3.122 casos corresponderam a necropsias de baleados. RESULTADOS: Desses casos, 309 corpos foram sepultados contendo ainda, no seu interior, projéteis de arma de fogo, podendo suscitar futuras indagações judiciais. No mesmo período foram solicitadas 23 exumações, 12 delas com a finalidade de recolher projéteis. Foram calculados os gastos relacionados à realização de necropsias de baleados - R$ 996,85 - e custos alusivos à realização de exumações com a finalidade de recolher projéteis de arma de fogo - R$ 1.155,40, visando a estabelecer o montante financeiro que poderia ser poupado pelos cofres públicos, a ser alocado para finalidades outras, se a perícia médico-legal de baleados, no exame inicial, obtivesse sucesso. CONCLUSÃO: Os resultados permitiram concluir que todos os atos necroscópicos de baleados devem seguir protocolos específicos, uma vez que perícias incompletas exigem exumação posterior, com gastos adicionais desnecessários.
Resumo:
The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.
Resumo:
Tutkimuksessa on tarkoitus selvittää velallisen asemaa perinnässä ja perintäkulujen merkitystä. Tutkimus jakautuu teoreettiseen ja empiiriseen osaan, jossa selvitetään teoreettisesti velkaan ja perintään liittyviä käsitteitä ja lainsäädäntöä. Laki saatavien perinnästä sääntelee yleislakina perintätoimintaa riippumatta siitä suorittaako perintää itse velkoja vai perimistoimisto. Lakiin otettiin vuonna 2005 kuluttajasaatavia koskevia perimiskuluja rajoittavat enimmäismäärät, jotka on porrastettu saatavan suuruuden mukaan. Empiirisessä osassa tutkitaan oikeudenkäyntiaineistosta kerätyistä tiedoista perintään kuuluvia osapuolia, perittäviä saatavia ja perimiskuluja. Velallisen asema näyttää olevan riittävän hyvin turvattu oikeusjärjestyksessämme, joskin perimiskulujen ja oikeudenkulujen määrä nousee usein itse perittävää pääomaa suuremmaksi. Rahasaatavien perintää koskevien tapausten määrä käräjäoikeuksissa on kasvanut huomattavasti vuonna 2007. Tällaisia velkomuksia käsiteltiin käräjäoikeuksissa yli 200.000 kappaletta vuonna 2007. Tämän kasvun osaltaan selittää uudeksi velkaongelmien aiheuttajaksi nousemassa olevat pikavipit, joiden määrä kaikista perittävistä saatavista oli noin 10%. Näiden pääomat olivat keskiarvoltaan noin 145 euroa, ja näiden perintäkulut noin kaksinkertaisia verrattuna pääomaan Koko aineistossa perityt pääomat olivat keskiarvoltaan noin 2900 euroa ja perintäkulut noin 270 euroa.
Resumo:
Network neutrality is a growing policy controversy. Traffic management techniques affect not only high-speed, high-money content, but by extension all other content too. Internet regulators and users may tolerate much more discrimination in the interests of innovation. For instance, in the absence of regulatory oversight, ISPs could use Deep Packet Inspection (DPI) to block some content altogether, if they decide it is not to the benefit of ISPs, copyright holders, parents or the government. ISP blocking is currently widespread in controlling spam email, and in some countries in blocking sexually graphic illegal images. In 1999 this led to scrutiny of foreclosure of Instant Messaging and video and cable-telephony horizontal merger. Fourteen years later, there were in 2013 net neutrality laws implemented in Slovenia, the Netherlands, Chile and Finland, regulation in the United States and Canada , co-regulation in Norway, and self-regulation in Japan, the United Kingdom and many other European countries . Both Germany and France in mid-2013 debated new net neutrality legislation, and the European Commission announced on 11 September 2013 that it would aim to introduce legislation in early 2014. This paper analyses these legal developments, and in particular the difficulty in assessing reasonable traffic management and ‘specialized’ (i.e. unregulated) faster services in both EU and US law. It also assesses net neutrality law against the international legal norms for user privacy and freedom of expression
Resumo:
This study extends the standard econometric treatment of appellate court outcomes by 1) considering the role of decision-maker effort and case complexity, and 2) adopting a multi-categorical selection process of appealed cases. We find evidence of appellate courts being affected by both the effort made by first-stage decision makers and case complexity. This illustrates the value of widening the narrowly defined focus on heterogeneity in individual-specific preferences that characterises many applied studies on legal decision-making. Further, the majority of appealed cases represent non-random sub-samples and the multi-categorical selection process appears to offer advantages over the more commonly used dichotomous selection models.
Resumo:
Este artigo de revisão sistemática tem por objetivo citar os métodos de identificação humana por meio da radiologia, utilizados em odontologia legal. Para isso, realizou-se revisão de literatura com 19 trabalhos selecionados dentre 45 encontrados, após aplicação de critérios de inclusão. Há diversas técnicas radiológicas que podem ser utilizadas para auxiliar na identificação humana, tanto individual como geral, incluindo a determinação do gênero, do grupo étnico e, principalmente, da idade. A análise de radiografias e tomografias ante-mortem e post-mortem tornou-se uma ferramenta fundamental nos processos de identificação em odontologia legal, principalmente com o refinamento das técnicas adquiridas com o avanço da própria radio-logia e com a incorporação da informática. Conclui-se que a partir do conhecimento adequado dos métodos disponíveis, o profissional em odontologia legal pode optar pelo método que melhor preencha as características necessárias para o sucesso da identificação, tendo cuidado na aplicação correta da técnica e na interpretação precisa das informações obtidas.
Resumo:
Objective: To summarise and critically evaluate the evidence informing the provision of standard care practices and psychosocial interventions following stillbirth. Background: Stillbirth is increasingly recognised as a significant bereavement experience with the potential to cause substantial psychological distress for parents. Standard care practices and psychosocial interventions to support parents have undergone dramatic changes, with limited basis in evidence. Methods: A systematic narrative review was conducted of quantitative studies examining interventions designed to reduce psychological distress in parents following the loss of a stillborn baby. Results: Twenty-five studies met the inclusion criteria for the review. Substantial methodological weaknesses were identified among reviewed studies, including small and heterogeneous loss samples, weak study designs and lack of clarity in reported methods and outcomes. Inadequate replication of many findings substantially limits the generalisability of the evidence. Conclusion: Tentative evidence was found for the provision of mementoes of the baby and information regarding the cause of the loss, support group attendance, and cognitive behavioural interventions for parents identified with clinical levels of distress. Contradictory findings for the impact of contact with the baby prevent the formation of clear conclusions for this practice. Due to the methodological weaknesses prevalent in the research identified, the current evidence base is not considered sufficiently able to reliably inform care practices and intervention approaches. High-quality research evidence in this field is urgently required.
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.