989 resultados para Heart-assist devices
Resumo:
This paper describes how to extend the access to remote experiments from mobile devices, aiming to better engage digital native students who expect a more interactive and ubiquitous access mode. The extension is based on features of HTML5 and the jQuery Mobile framework, which allow accessing the experiments from different operating systems via the browser or native applications. As a result, users have a richer interaction mode with the experiments, which includes access from simple hand-held devices such as smartphones and PDAs. Extending the access to remote experiments, from simple devices, enables its use in other educational stages, such as high schools, where teachers struggle to engage students in STEM learning. By enabling students to use their everyday "technological companions", e.g. cellular phones, to access remote experiments, we seek to increase the educational value of this technology-enhanced learning resource.
Resumo:
In this article the authors describe the application development RExMobile and the importance of remote experimentation via mobile devices, especially smartphones simple, beyond the space provided for this application in education. The article deals the creation, software and hardware that provide an interactive and dynamic way to attract more students to use these experiments remote, serving as support to teachers to science teaching from its initial series. The ease and availability of smartphones, even these students of basic education, permits the reach of new users and in different places. Thus, the practice of remote experimentation in mobile devices enables new spaces for access and interaction. Are used for developing software free or low cost, HTML5 and jQuery Mobile framework, that enable the creation of pages compatible with different mobile operating systems such as iOS, Android, Windows Phone, some Symbian, among others. Also are demonstrated patterns layouts that allow greater accessibility.
Resumo:
The rapid increase in the use of microprocessor-based systems in critical areas, where failures imply risks to human lives, to the environment or to expensive equipment, significantly increased the need for dependable systems, able to detect, tolerate and eventually correct faults. The verification and validation of such systems is frequently performed via fault injection, using various forms and techniques. However, as electronic devices get smaller and more complex, controllability and observability issues, and sometimes real time constraints, make it harder to apply most conventional fault injection techniques. This paper proposes a fault injection environment and a scalable methodology to assist the execution of real-time fault injection campaigns, providing enhanced performance and capabilities. Our proposed solutions are based on the use of common and customized on-chip debug (OCD) mechanisms, present in many modern electronic devices, with the main objective of enabling the insertion of faults in microprocessor memory elements with minimum delay and intrusiveness. Different configurations were implemented starting from basic Components Off-The-Shelf (COTS) microprocessors, equipped with real-time OCD infrastructures, to improved solutions based on modified interfaces, and dedicated OCD circuitry that enhance fault injection capabilities and performance. All methodologies and configurations were evaluated and compared concerning performance gain and silicon overhead.
Resumo:
A melhoria progressiva na prestação de cuidados de saúde que se verifica nos dias de hoje, deve-se maioritariamente ao desenvolvimento de novas tecnologias médicas, que se traduzem na criação de inovadores dispositivos médicos, cujo fim é auxiliar no diagnóstico, prevenção e tratamento de doenças, melhorando assim as condições de trabalho e os cuidados oferecidos aos pacientes. No entanto estas melhorias apenas são vantajosas quando as novas tecnologias são utilizadas de forma segura, o que leva a uma preocupação crescente com a segurança dos profissionais de saúde e dos pacientes em ambiente hospitalar. Como forma de reduzir e controlar os riscos existentes, as unidades de saúde introduziram mecanismos de gestão que permitem o conhecimento das fontes de risco e respetivos mecanismos de ação. A presente dissertação de mestrado apresenta uma proposta de modelo de Manual de Procedimentos para Gestão de Risco de Dispositivos Médicos, aplicável a todos os dispositivos médicos existentes nas Unidades de Saúde. Para a criação deste manual, foram utilizados por meio de adaptação, as etapas da gestão de risco definidas na Norma ISO 14971:2007 em conjunto com o método de gestão de risco utilizado pela Unidade Local de Saúde de Matosinhos O desenvolvimento deste manual de procedimentos permitirá a esta unidade de saúde, a aquisição e fornecimento de informações úteis na tomada de decisão sobre os procedimentos de controlo de risco de dispositivos médicos, com o objetivo de manter o risco destes dispositivos dentro dos níveis previamente estabelecidos e auxiliar a tomada de decisão de programas de manutenção preventiva e de aquisição de dispositivos médicos.
Resumo:
Fault injection is frequently used for the verification and validation of the fault tolerant features of microprocessors. This paper proposes the modification of a common on-chip debugging (OCD) infrastructure to add fault injection capabilities and improve performance. The proposed solution imposes a very low logic overhead and provides a flexible and efficient mechanism for the execution of fault injection campaigns, being applicable to different target system architectures.
Resumo:
Com o envelhecimento da população, as preocupações com a garantia do seu bem-estar aumentam criando a necessidade de desenvolver ferramentas que permitam monitorizar em permanência este sector da população. A utilização de smartphones pelos mais velhos pode ser crucial no seu bem-estar e na sua autonomia contribuindo para a recolha de informação importante já que estes estão muitas vezes equipados com sensores que podem dar indicações preciosas ao cuidador sobre o estado atual do paciente. Os sensores podem fornecer dados sobre a atividade física do paciente, bem como detetar quedas ou calcular a sua posição, com a ajuda do acelerómetro, do giroscópio e do sensor de campo magnético. No entanto, funcionalidades como essas requerem, obrigatoriamente, uma frequência de amostragem mínima por parte dos sensores que permita a implementação de algoritmos, que determinarão esses parâmetros da forma mais exata possível. Dado que nem sempre os pacientes se fazem acompanhar do seu smartphone quando estão na sua residência, a criação de ambientes de AAL (Ambient Assisted Living) com recurso a dispositivos externos que podem ser “vestidos” pelos pacientes pode também ser uma solução adequada. Estes contêm normalmente os mesmos sensores que os smartphones e comunicam com estes através de tecnologias sem fios, como é o caso do Bluetooth Low Energy. Neste trabalho, avaliou-se a possibilidade de alteração da frequência dos sensores em diferentes sistemas operativos, tendo sido efectuadas modificações nas instalações por defeito de alguns sistemas operativos abertos. Com o objectivo de permitir a criação de uma solução de AAL com recurso a um dispositivo externo implementaram-se serviços e perfis num dispositivo externo, o SensorTag.
Resumo:
Trabalho de Projeto realizado para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
From January 1988 to January 1989 all the heart transplant and bone marrow recipients at the Instituto do Coração of the Hospital das Clínicas of the University of São Paulo Medical School were studied for the incidence and morbidity associated with herpesviruses infections after transplantation. Five bone marrow and 5 heart transplant recipients were followed for a mean of 4.2 months post-transplantation. All the patients were seropositive for cytomegalovirus (CMV) before admission and 80% experienced one or more recurrences during the observation period. Of the 12 episodes of CMV infection, that were identified in this study, 83% were accompanied by clinical or laboratory abnormalities. However, there was only one case of severe disease. The overall incidence of infection for herpes simplex (HSV) was 50%. Although most of HSV reactivations were oral or genital, one case of HSV hepatitis occurred. One of the 6 episodes of HSV infections that were treated with acyclovir showed an unsatisfactory response and was successfully managed with ganciclovir. All the individuals had anti-varicella zoster virus antibodies, but none of them developed infection. The study emphasizes the importance of active diagnostic surveillance of herpesvirus infections in transplant patients. Both CMV and HSV reactivations showed high incidence and important morbidity and thus, deserve prophylactic therapy.
Resumo:
Mobile devices are embedded systems with very limited capacities that need to be considered when developing a client-server application, mainly due to technical, ergonomic and economic implications to the mobile user. With the increasing popularity of mobile computing, many developers have faced problems due to low performance of devices. In this paper, we discuss how to optimize and create client-server applications for in wireless/mobile environments, presenting techniques to improve overall performance.
Resumo:
The capability to anticipate a contact with another device can greatly improve the performance and user satisfaction not only of mobile social network applications but of any other relying on some form of data harvesting or hoarding. One of the most promising approaches for contact prediction is to extrapolate from past experiences. This paper investigates the recurring contact patterns observed between groups of devices using an 8-year dataset of wireless access logs produced by more than 70000 devices. This effort permitted to model the probabilities of occurrence of a contact at a predefined date between groups of devices using a power law distribution that varies according to neighbourhood size and recurrence period. In the general case, the model can be used by applications that need to disseminate large datasets by groups of devices. As an example, the paper presents and evaluates an algorithm that provides daily contact predictions, based on the history of past pairwise contacts and their duration. Copyright © 2015 ICST.
Resumo:
Os dispositivos móveis são pessoais, intransmissíveis e cada vez mais utilizados, tornando-se assim numa boa ferramenta para a realização de um conjunto de serviços na indústria hoteleira. Entre esses serviços que necessitam da identificação pessoal, encontram-se a possibilidade do cliente reservar um quarto ou utilizar o serviço de quartos. Atualmente é muito utilizado, nos locais de alojamento, um smart card que possibilite ao cliente ter acesso a alguns dos serviços disponíveis. O objetivo deste documento é apresentar uma alternativa ao sistema de cartões, utilizando para o efeito, dispositivos móveis. De modo a garantir a segurança e uma utilização semelhante ao sistema de cartões existentes foi utilizada a tecnologia NFC (Near Field Communication) que, ao permitir o modo de emulação de cartão, facilita a transação do sistema de smart card existente, para o da utilização de dispositivos móveis na realização das mesmas funções. Mais concretamente, será abordada a utilização de smartphones para o processo de abertura de portas. Para que exista uma melhor compreensão e para que haja um conhecimento das suas capacidades e limites foram estudados casos de uso da tecnologia NFC. Este documento apresenta ainda os processos de desenvolvimento de uma aplicação nativa para o sistema operativo Android, cujo objetivo é proporcionar ao cliente de um local de alojamento um novo modo de acesso ao quarto, utilizando a tecnologia NFC. Para além desta funcionalidade a aplicação permite ainda ao utilizador fazer reservas, fazer o check-in, fazer o check-out entre outras. Posteriormente serão apresentadas as conclusões e possíveis trabalhos futuros.
Consumption Management of Air Conditioning Devices for the Participation in Demand Response Programs
Resumo:
Demand Response has been taking over the years an extreme importance. There’s a lot of demand response programs, one of them proposed in this paper, using air conditioners that could increase the power quality and decrease the spent money in many ways like: infrastructures and customers energy bill reduction. This paper proposes a method and a study on how air conditioners could integrate demand response programs. The proposed method has been modelled as an energy resources management optimization problem. This paper presents two case studies, the first one with all costumers participating and second one with some of costumers. The results obtained for both case studies have been analyzed.
Resumo:
This prospective study on 41 autopsy collected human hearts concerns the "apical" lesion in Chagas' disease. Previous report did not show a correlation between lesion frequency and heart weight then discarding a vascular factor in its pathogenesis. The present paper involves other variables besides the heart weight to evaluate the relative coronary insufficiency. Distinct colored gel (green and red) injected through the capillary beds of both coronary arteries defined the extent of both vessels before separating the atria and removing the sub-epicardium fat. The Right Ventricle (RV) and Left Ventricle (LV) free walls furnished the RV/LV mass ratio. The myocardium mass colored green (right coronary artery - RC) and the whole Ventricular Weight (VW) determined the RC/VW mass ratio. The heart weight plus these mass ratios, graded and added, composed a score inversely proportional to the myocardium irrigation condition. It intended to be a more sensitive morphologic evaluation of the relative ischaemia to correlate to the apical lesion. This study showed a right deviation for the relative accumulated frequency of lesions plotted as a score function and a significant difference for higher scores in hearts with aneurysm. It suggests a ischaemic factor intervening in the apical lesion pathogenesis in Chagas' cardiopathy.
Resumo:
A crescente utilização de dispositivos móveis com diferentes finalidades é uma realidade. Com estes dispositivos, o utilizador tem a necessidade de aceder e usar dados em tempo real provenientes de diversas fontes. Uma tendência acentuada passa pela incorporação destes dispositivos móveis no vestuário, designados por dispositivos wearable. Segundo a empresa IMS Research, o mercado deste tipo de dispositivos irá aumentar de 14 milhões de unidades registadas no presente ano (2013), para cerca de 171 milhões em 2016, sendo esta previsão conservadora, segundo o analista da IMS Research, Theo Ahadome [15]. A maioria dos dispositivos portáteis está atualmente projetada para questões de saúde, como a monitorização do nível de glicose e batimento cardíaco. O objetivo deste trabalho passa por definir e implementar um dispositivo wearable para aplicações de saúde com um conjunto de funcionalidades para monitorização dos sinais vitais do utilizador. Posteriormente esta base pode ser aplicada em cenários de aplicação distintos, em que todos os dispositivos comunicam entre si, e fazem o reencaminhamento da informação para onde mais interessar. Foi desenhado e implementado hardware e software, para a construção de aplicações capazes de realizar a monitorização do batimento cardíaco, temperatura e humidade corporal, deteção de quedas, qualidade do sono, e chamadas de emergência. Este trabalho aborda os diferentes cenários e aplicações da utilização deste dispositivo, invocando as necessidades específicas de cada situação, sendo estas necessidades trabalhadas e transformadas em características e especificações do sistema. A plataforma de hardware e software permite criar um ecossistema de aplicações, permitindo usar todas as infraestruturas do sistema desenvolvido em futuros cenários de aplicação.