929 resultados para Energy Performance of Buildings
Resumo:
Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.
Resumo:
According to the producers, CHROMagar (TM) Listeria medium comes to facilitate the detection, differentiating Listeria monocytogenes from the other species, directly on the isolation process, allowing final results in 72 h, while the traditional method takes up to 10 days. A total of 120 food samples of sliced cooked ham, ground beef and frankfurters was analyzed. From 151 colonies presenting typical L. monocytogenes characteristics on CHROMagar (TM) Listeria (bluish, surrounded by a white halo), only 95 (62.9%) were confirmed as L. monocytogenes. The medium was highly sensitive to detect L. monocytogenes in ground beef and frankfurter, but not in sliced ham. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Limb praxis can be influenced by age, gender, and education. The present Study investigated the influence of these variables on gesture production by healthy elderly Subjects. We evaluated 96 individuals divided into two age groups (60-74 and 75-88 years). Each group contained 48 men and 48 women and was subdivided into four groups according to education: illiterates and 1-3, 4-7, and 8 or more years of education. Individuals were requested to carry Out tasks oil verbal command and imitation. There were no differences between the performance of men and women, while older individuals performed worse than their younger counterparts. Regarding educational level, three major groups emerged: illiterates, individuals with 1-7 years of education, and those with 8 or more years of education. In conclusion, age and education significantly influenced the performance of individuals in limb praxis tests. (JINS, 2009, 157 618-622.)
Resumo:
The common bean is affected by several pathogens that can cause severe yield losses. Here we report the introgression of resistance genes to anthracnose, angular leaf spot and rust in the `carioca-type` bean cultivar `Ruda`. Initially, four backcross (BC) lines were obtained using `TO`, `AB 136`, `Ouro Negro` and `AND 277` as donor parents. Molecular fingerprinting was used to select the lines genetically closer to the recurrent parent. The relative genetic distances between `Ruda` and the BC lines varied between 0.0% and 1.99%. The BC lines were intercrossed and molecular markers linked to the resistance genes were used to identify the plants containing the genes of interest. These plants were selfed to obtain the F(2), F(3) and F(4) plants which were selected based on the presence of the molecular markers mentioned and resistance was confirmed in the F(4) generation by inoculation. Four F(4:7) pyramid lines with all the resistance genes showed resistance spectra equivalent to those of their respective donor parents. Yield tests showed that these lines are as productive as the best `carioca-type` cultivars.
Resumo:
Current visceral leishmaniasis (VL) control programs in Brazil include the infected dog elimination but, despite this strategy, the incidence of human VL is still increasing. One of the reasons is the long delay between sample collection, analysis, control implementation and the low sensitivity of diagnostic tests. Due to the high prevalence of asymptomatic dogs, the diagnosis of these animals is important considering their vector infection capacity. Hence, a rapid and accurate diagnosis of canine visceral leishmaniasis is essential for an efficient surveillance program. In this study we evaluated the performance of rK39 antigen in an immunochromatographic format to detect symptomatic and asymptomatic Leishmania chagasi infection in dogs and compared the results with those using a crude antigen ELISA. The sensitivity of rK39 dipstick and ELISA were 83% vs. 95%, respectively, while the specificity was both 100%. Our results also demonstrated that the dipstick test was able to detect infected dogs presenting different clinical forms. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This study aimed to compare Petrifilm Aerobic Count (AC) plates and the conventional pour plate methodology using the de Man-Rogosa-Sharpe (MRS) agar for the enumeration of lactic acid bacteria (LAB) in fermented milks (FMs), with different starter cultures added. FM samples (n = 66) were collected and plated on both methodologies, with incubation under anaerobic conditions at 35C for 48 h. The count results were compared by analysis of variance (P <= 0.05) and regression analysis. No differences between the mean counts obtained by both methodologies were observed, even when distinct FMs were compared. Considering all samples, a high correlation level was obtained between Petrifilm AC and MRS agar (r = 0.92), but these indexes were lower in FMs with Streptococcus thermophilus and Lactobacillus delbrueckii subsp. bulgaricus (r = 0.90) and Lactobacillus fortis (r = 0.81). Despite some slight interferences, Petrifilm AC has proven to be a convenient methodology on enumerating LAB in FM.
Resumo:
Objectives: The aim of this study was to compare the fracture strength of three techniques used to re-attach tooth fragments in sound and endodontically treated fractured teeth with or without fiber post placement. Material and methods: Ninety human lower incisors were randomly divided into three groups of 30 teeth each. In group A teeth were not subjected to endodontic treatment; while teeth from groups B and C were endodontically treated and the pulp chamber restored with a composite resin. All teeth were fractured by an axial load applied to the buccal area in order to obtain tooth fragments. Teeth from each group were then divided into three subgroups, according to the re-attachment technique: bonded-only, buccal-chamfer and circumferential chamfer. Before the re-attachment procedures, fiber posts were placed in teeth from group C using dual cure resin luting cement (Duo-Link). All teeth (groups A-C) had the fragments re-attached using a same dual cure resin luting cement. in the bonded-only group, no additional preparation was made. After re-attachment of the fragment, teeth from groups buccal and circumferential chamfer groups had a 1.0 mm depth chamfer placed in the fracture line either on buccal surfaceor along the buccal and lingual surfaces, respectively. increments of microhybid composite resin (Tetric Ceram) were used in subgroups buccal chamfer and circumferential chamfer to restore the chamfer. The specimens were loaded until fracture in the same pre-determined area. The force required to detach each fragment was recorded and the data was subjected to a three-way analysis of variance where factors Group and Re-attachment technique are independent measures and Time of fracture is a repeated measure factor (first and second) and Tukey`s test (alpha = 0.05). Results: The main factors Re-attachment technique (p = 0.04) and Time of fracture (p = 0.02) were statistically significant. The buccal and circumferential chamfer techniques were statistically similar (p > 0.05) and superior to the bonded-only group (p < 0.05). The first time of fracture was statistically superior to second time of fracture (p < 0.001). Conclusions: The use of fiber post is not necessary for the reinforcement of the tooth structure in re-attachment of endodontically treated teeth. When bonding a fractured fragment, the buccal or circumferential re-attachment techniques should be preferable in comparison with the simple re-attachment without any additional preparation. None of the techniques used for re-attachment restored the fracture strength of the intact teeth. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Statement of purpose: Increased resting energy expenditure following head injury is well documented, but whether this increase extends into rehabilitation and whether this is affected by changes in body composition have not been studied. The aim of this study was to determine whether children attending a rehabilitation program following head injury had altered energy expenditure and body composition. Methods: Measurements of resting energy expenditure by indirect calorimetry were performed in 21 head injured children (mean age 10.2±3.8 years). Measurement of body composition was performed using total body potassium. Results: Measured resting energy expenditure values were widely distributed, ranging from 52.3-156.4% of predicted values, yet the mean percentage predicted using Schofield weight, Schofield weight and height and World Health Organization predictive equations were 97.5%, 97.4% and 98.6%, respectively. Mean percentage of expected total body potassium for weight, height and age for head injured children were 85.1 ± 15.5%, 89.1 ± 14.1% and 86.9 ± 15.9%, thus all showed significant depletion. Conclusions: During rehabilitation, using predictive equations to estimate resting energy expenditure in this group revealed a small bias on average but very large bias at the individual level. Head injured children had altered resting energy expenditure and body composition.
Resumo:
Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)
Resumo:
There is currently some debate about whether the energy expenditure of domestic tasks is sufficient to confer health benefits. The aim of this study was therefore to measure the energy cost of five activities commonly undertaken by mothers of young children. Seven women with at least one child younger than five years of age spent 15 minutes in each of the following activities: sitting quietly, vacuum cleaning, washing windows, walking at moderate pace (approx 5km/hour), walking with a stroller and grocery shopping in a super-market. Each of the six 'trials' was completed on the same day, in random order. A carefully calibrated portable gas analyser was used to measure oxygen uptake during each activity, and data were converted to units of energy expenditure (METS). Vacuum cleaning, washing windows and walking with and without a stroller were found to be 'moderate intensity activities' (3 to 6 METs), but supermarket shopping did not reach this criterion. The MET values for these activities were similar to those reported in the Compendium of Physical Activities (Ainsworth et al., 2000). However, the energy expenditures of walking, both with and without a stroller, were higher than those reported in the Compendium. The findings suggest that some of the tasks associated with domestic caring duties are conducted at an intensity which is sufficient to confer some health benefit. Such benefits will only accrue however if the daily duration of these activities is sufficient to meet current guidelines.
Resumo:
Objective: The purpose of this study was to compare the energy cost of standardized physical activity (ECA) between patients with cystic fibrosis (CF) and healthy control subjects. Design: Cross-sectional study using patients with CF and volunteers from the community. Setting: University laboratory. Subjects: Fifteen patients (age 24.6 +/- 4.6 y) recruited with consent from their treating physician and 16 healthy control subjects (age 25.3 +/- 3.2) recruited via local advertisement. Interventions. Patients and controls walked on a computerised treadmill at 1.5 km/h for 60 min followed by a 60 min recovery period and, on a second occasion, cycled at 0.5 kp (kilopond), 30 rpm followed by a 60 min recovery. The ECA was measured via indirect calorimetry. Resting energy expenditure (REE), nutritional status, pulmonary function and genotype were determined. Results: The REE in patients was significantly greater than the REE measured in controls (P = 0.03) and was not related to the severity of lung disease or genotype. There was a significant difference between groups when comparing the ECA for walking kg root FFM (P = 0.001) and cycling kg root FFM (P = 0.04). The ECA for each activity was adjusted (ECA(adj)) for the contribution of REE (ECA kJ kg root FFM 120 min(-1) - REE kJ kg root FFM 120 min(-1)). ECA(adj) revealed a significant difference between groups for the walking protocol (P = 0.001) but no difference for the cycling protocol (P = 0.45). This finding may be related to the fact that the work rate during walking was more highly regulated than during cycling. Conclusions ECA in CF is increased and is likely to be explained by an additional energy-requiring component related to the exercise itself and not an increased REE. Sponsorship. The Prince Charles Hospital Foundation; MLR was in receipt of a QUTPRA Scholarship.
Resumo:
Purpose: The aim of this study was to assess the accuracy of a (CO2)-C-13 breath test for the prediction of short-duration energy expenditure. Methods: Eight healthy volunteers walked at 1.5 km.h(-1) for 60 min followed by 60-min recovery. During this time, the energy cost of physical activity was measured via respiratory calorimetry and a C-13 bicarbonate breath test. A further eight subjects were tested using the same two methods during a 60-min cycle at 0.5 kp. 30 ipm followed by a 60-min recovery. The rate of appearance of (CO2)-C-13, (RaCO2) was measured and the mean ratio, (V) over dot CO2/RaCO2 was used to calculate energy expenditure using the isotopic approach. Results: As would be expected, there was a significant difference in the energy cost of walking and cycling using both methods (P < 0.05). However. no significant differences were observed between respiratory calorimetry and the isotope method for measurement of energy expenditure while walking or cycling. Conclusions: These data suggest that the C-13 breath test is a valid method that can be used to measure the energy cost of short duration physical activity in a field setting.
Resumo:
Passive techniques as an alternative to artificial cooling can bring important energy, environmental, financial, operational and qualitative benefits. However, regions such as the wet tropics can reach high levels of thermal stress in which passive means alone are unable to provide appropriate thermal comfort standards for some parts of the year. Despite a great accumulation of empirical information on the passive performance of houses for either free-running or conditioned modes, very little work has been done on the thermal performance of buildings that can operate with a mixed-running strategy in warm-humid climates. Buildings with such design features are able to balance the needs for comfort, privacy, and energy efficiency during different periods of the year. As free-running and conditioned modes are believed by many to be 'opposite' approaches, and have been presented as separate strategies, this paper demonstrates that not all parameters are directly opposite and a possible dual-mode integrated operation can be used for warm-humid locations for maximum comfort and minimum energy requirements. For this purpose, simulation runs using ESP-R (University of Strathclyde, ESRU, UK) were based on the climate data of Darwin (Australia) and on the ventilation styles of the house: free running and conditioned. Design features applicable to both, i.e. for a dual mode operation could be identified and the differences between conditioned and free running were demonstrated and proved not to be totally conflicting and therefore suitable for a dual mode operation. Different daily usage profiles (five use patterns were defined), and zoning of sleeping and living areas are presented. The dual mode use patterns compared to the base case house, for all the user possibilities, had improved performances of 17-52%, when compared to the free-running mode and 66-98% when compared to the conditioned mode. Simulation runs using other warm-humid climates (Miami, USA; Sao Luis, Brazil; Kuala Lumpur, Malaysia) were also conducted and compared to the results found for Darwin. (C) 2002 Elsevier Science Ltd. All rights reserved.