959 resultados para Corrente elétrica
Resumo:
Patellofemoral pain syndrome (PFPS) is described as anterior or retropatellar pain knee in the absence of other pathologies and is frequently associated with dysfunction of the vastus medialis oblique (VMO). However, several studies have demonstrated the inability to selectively activate this muscle through exercise. To evaluate the effect of Neuromuscular Electrical Stimulation (NMES) selective VMO in women with syndrome. We evaluated thirty-eight women: twenty in the control group (24.15 ± 2.60 years) and eighteen diagnosed with PFPS (25.56 ± 3.55 years). Both groups were evaluated before and after a protocol of electro stimulation. To measure for comparing groups before and after treatment, we assessed the extensor torque concentric and eccentric knee through an isokinetic dynamometer, the intensity (Root Mean Square - RMS) and the onset of activation (onset) of VMO compared to the vastus lateralis (VL) in two types of exercise: open and closed kinetic chain. . Statistical analysis was performed using SPSS 15.0, with a significance level of 5%. Results: Our data showed an increase in the intensity of activation (RMS) of the VMO muscle after NMES in both study groups. During concentric contraction the RMS of the VMO before the NMES was 105.69 ± 32.26 μV and after a single intervention was 122.10 ± 39.62 μV (p = 0.048) for the control group. In the group with PPS, we found a similar behavior, with RMS of the VMO before NMES of 96.25 ± 18.83 μV and 139.80 ± 65.88 μV after the intervention (p = 0.0001). However, there was no evidence in the RMS value of VL muscle. The onset was calculated by subtracting the onset of VL by the onset of VMO. For the group with PFPS, the onset before the intervention was -0.007 ± 0.14 ms, indicating a delay of the VMO relative to VL, and after NMES was 0.074 ± 0.09 ms (p = 0.016), showing an activation previous VMO to VL. The same occurred for the control group. We also observed that NMES increased knee extensor power during the concentric contraction in both groups. Before the intervention the mean power was 28.97 ± 9.01 W for the PPS group and after NMES was 34.38 ± 7.61 W (p = 0.0001). Conclusion: We observed an increase in electromyographic activity of the VMO and also an anticipatory effect of this muscle
Resumo:
To analyze the effects of electrical stimulation at two frequencies on the EMG parameters (EMG) and dynamometer, in muscles with different typing. MATERIALS AND METHODS: This is a controlled clinical trial, randomized and double blind. Sixty healthy volunteers (23.6 ± 4.2anos; 54.2 ± 7.7kg, 1.62 ± 0.009 cm) of both sexes were divided randomly into three groups: control group (CG), experimental group 1 (SG1) with application of the current Russian 30 HZ and experimental group 2 (EG2) at 70 Hz The volunteers performed an initial assessment (AV1) on the isokinetic dynamometer with three repetitions maximum voluntary isometric (MVC) for knee extension concomitant uptake of EMG for the VM muscle, VL and RF. Later, after application of NMES, they underwent an experimental protocol of isometric fatigue using 70% of MVIC, ending with the completion of a final assessment (AV2) in the same manner as the AV1. RESULTS: By analyzing the profile of the 60 subjects in three broad, VM showed a higher value of RMS behavior when the VL and RF (p = 0.03 and p = 0.02). With respect to Fmed the RF muscle (p = 0.001) showed a higher value for the VM. The VM muscle showed significant increases of Fmed (p = 0.05) after electrical stimulation at 70 Hz when compared the AV1 AV2 and RF showed significant decreases (p = 0.009) after stimulation at 30 Hz during the fatigue showed an increase RMS in the VM and VL, with a reduction in RF. For the variable Fmed was observed in three broad decline during fatigue. CONCLUSION: Our findings provide evidence that the muscles VM, VL and RF fiber typing are different besides indicating that the frequency of NMES tend to relate to the muscle stimulated. Finally suggests the surface EMG as a noninvasive method for characterizing muscle
Resumo:
The reduction of physiological capacity present in the process of aging causes a marked decline in lung function. The exercise does promote several positive changes in the physical health of people and protect the cardiorespiratory function. The aim of this study was to investigate the effects of a program of Pilates exercices on the strengh and electrical activity of respiratory muscles of elderly. This is a randomized, controlled clinical trial, evaluating 33 elderly aged 65 and 80 (70.88 ± 4.32), healthy, sedentary, without cognitive impairment and able the practice physical activity. The sample was divided into two groups, one experimental group with 16 elderly women who did Pilates exercises and a control group (17) that was not submitted to the exercises, but received educational booklets on aging and health care. The elderly were evaluated initially and after a period of three months, taking into account the Maximal Inspiratory Pressure (MIP) and Maximal Expiratory Pressure (MEP), obtained by Manovacuometry and intensity of EMG activity was measured using the values of Root Mean Square (RMS) for the diaphragm and rectus abdominis muscles, during the course of diaphragmatic breathing and MIP maneuver. Data were analyzed using SPSS version 17.0. For all tests, we used a significance level or p value < 0.05 and confidence interval 95%. RMS in diaphragm and rectus abdominis muscles in both tests increased, but the data were significant for the rectus abdominis during diaphragmatic breathing (p = 0.03) and the diaphragm during the MIP maneuver (p = 0.01). There was no significant variation of the MIP and MEP. Pilates exercises were responsible for increasing the electrical activation of the diaphragm and rectus abdominis muscles in a group of healthy elderly, but had no influence on changes in strength of respiratory muscles
Resumo:
O objetivo deste trabalho é divulgar, por meio de uma tradução comentada, um dos principais trabalhos escritos por Dominique François Jean Arago (1786-1853) relativo ao eletromagnetismo. Trata-se de uma descrição das experiências feitas por ele, relativas à magnetização do ferro e do aço pela ação da corrente voltaica.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, the treatment of synthetic wastewaters containing Remazol Red BR (RRB) and Novacron Blue C-D (NB) by anodic oxidation using boron doped diamond anodes (BDD) and Novacron Yellow (YN) using BDD and Platinum (Pt) anodes was investigated. Galvanostatic electrolyses of RRB and NB synthetic wastewaters have led to the complete decolorization removal at different operating conditions (current density, pH and temperature). The influence of these parameters was investigated in order to find the best conditions for dyestuff colour removal. According to the experimental results obtained, the electrochemical oxidation process is suitable for decolorizing wastewaters containing these textile dyes, due to the electrocatalytic properties of BDD and Pt anode. Energy requirements for removing colour during galvanostatic electrolyses of RRB, NB and YN synthetic solutions depends mainly on the operating conditions; for example for RRB, it passes from 3.30 kWh m-3 at 20 mA cm-2 to 4.28 kWh m-3 at 60 mA cm-2 (pH = 1); 15.23 kWh m-3 at 20 mA cm-2 to 24.75 kWh m-3 at 60 mA cm-2 (pH = 4.5); 10.80 kWh m-3 at 20 mA cm-2 to 31.5 kWh m-3 at 60 mA cm-2 (pH = 8) (data estimated per volume of treated effluent). In order to verify the Brazilian law regulations of NB and RRB synthetic solutions after electrochemical decolourisation treatment, Hazen Units values were determined and the total colour removal was achieved; remaining into the regulations. Finally, electrical energy cost for removing colour was estimated
Resumo:
Many pollutants dumped in waterways, such as dyes and pesticides, have become so ubiquitous that they represent a serious threat to human health. The electrochemical oxidation is presented as an alternative clean, efficient and economic degradation of wastewater containing organic compounds and a number of advantages of this technique is to just not make use of chemical reagents, since only electrical energy is consumed during the removal of pollutants organic. However, despite being a promising alternative, still needs some tweaking in order to obtain better efficiency in the elimination of persistent pollutants. Thus, this study sought a relationship between a recently discovered phenomenon that reflects the participation of dissolved oxygen in solution in the electrochemical oxidation process, as an anomaly, present a kinetic model that shows instantaneous current efficiency (ICE) above 100% limited by theory, manifested for some experiments with phenolic compounds with H2SO4 or HClO4 as supporting electrolyte with electrodes under anodic oxidation on boron doped diamond (BDD). Therefore it was necessary to reproduce the data ICE exposes the fault model, and thus the 2-naphthol was used as phenolic compound to be oxidised at concentrations of 9, 12 and 15 mmol L-1, and H2SO4 and HClO4 to 1 mol L-1 as a supporting electrolyte under a current density of 30 mA cm-2 in an electrochemical reactor for continuous flow disk configuration, and equipped with anodes DDB at room temperature (25 oC). Experiments were performed using N2 like as purge gas for eliminate oxygen dissolved in solution so that its influence in the system was studied. After exposure of the anomaly of the ICE model and investigation of its relationship with dissolved O2, the data could be treated, making it possible for confirmation. But not only that, the data obtained from eletranálise and spectroscopic analysis suggest the involvement of other strongly oxidizing species (O3 (ozone) and O radicals and O2 -), since the dissolved O2 can be consumed during the formation of new strong oxidizing species, not considered until now, something that needs to be investigated by more accurate methods that we may know a little more of this system. Currently the performance of the electrocatalytic process is established by a complex interaction between different parameters that can be optimized, so it is necessary to the implementation of theoretical models, which are the conceptual lens with which researchers see
Resumo:
O trabalho teve por objetivo estudar metodologias para a condução do teste de condutividade elétrica, verificando sua eficiência na identificação de diferentes níveis de vigor de lotes de sementes de rúcula. Para tanto, o estudo foi conduzido utilizando cinco lotes de sementes de Rúcula Cultivada e cinco lotes de sementes de Rúcula Gigante. Foram realizados os testes de germinação, primeira contagem de germinação, emergência de plântulas em casa de vegetação e variações no teste de condutividade elétrica (temperaturas de 20ºC, 25ºC e 30ºC; volumes de 25mL, 50mL e 75mL de água; 25 e 50 sementes; e períodos de 1, 2, 4, 6, 8, 12, 16 e 24 horas). Diante dos resultados obtidos, verificou-se que o tempo de embebição para o teste de condutividade elétrica pode ser reduzido para 4 horas e o volume de água utilizado pode ser reduzido para 25 ou 50mL. As combinações de 50 sementes apresentaram menor coeficiente de variação e as temperaturas mais adequadas foram de 25ºC e 30ºC. Assim, concluiu-se que a condição mais adequada para o teste de condutividade elétrica em sementes de rúcula é a utilização de 50 sementes em 50mL de água por 4 horas, a 25ºC.
Resumo:
The high quality of seed trading for producers is very important to obtain high productivity. The aim of this work was to evaluate the effects of different periods of artificial seed aging on contents of sugars, proteins, amino acids and ions, on imbibition solution of electrical conductivity test, as well as its relationships with standard germination and vigor in bean seeds at the Perola cultivar. The research was carried out at the Laboratory of Seed Analysis - Faculdade de Engenharia - Unesp - Campus de Ilha Solteira. The experimental design was in completely randomized blocks. The seeds were submitted to eight accelerated aging conditions (zero, 24, 48, 72, 96, 120, 144 and 168 hours). The seed germination, seed vigor and leakage contents in exudates of bulk conductivity were Influenced by the increase in the time of seed exposition to accelerated aging. After seventy-two hours of exposition to the aging, a considerable decline in seed germination and vigor was observed. There was also an increase of leakage contents, such as amino acids, sugars, potassium and phosphorus ions. The increase of leakage contents is inversely related to seeds germination and vigor.
Resumo:
This work presents results derived from a study related to impact on non-controllable costs in the determination of energy taxes. This is done analyzing tax review practiced by concessionaries responsible for the distribution of electrical energy located in the Northeastern Region of Brazil, between 2003 and 2004. This Region was chosen as a study area due to the researcher s expectation in congregating companies that deliver services to markets that have similar social-economical profiles. A brief explanation related to the restructuring of the electrical sector in Brazil is presented, pointing out that there was privatization of the great majority of these companies. The study also points out the definition of regulating rules in service delivery process. The components of taxes that are practiced by these companies aimed at final consumers, as well as the market as a whole and the revision process that is executed by Agência Nacional de Energia Elétrica ANEEL for the definition of these taxes are demonstrated in the research. A brief historical of the concessionaires that were focus of the research is presented, totaling five companies. Some data used by ANEEL in the tax review process was analyzed as well as data on components of approved taxes. It is concluded that as a media 47, 49% of the components of taxes in the researched companies correspond to the non-controllable costs. These is done considering previous classification by ANEEL in the tax review process. Although, if it is considered that these companies since 2006, by the means of participation in energy auctions are able to negotiate energy prices for their own needs, it is concluded that these concession contracts guarantee the delivery of the service to the costumer in the total tribute. The percentage of non-controllable costs is 16, 27% average of the tax. This means, amongst other information, that the government has a great deal of responsibility in the formation of price practiced by these companies and its target markets
Resumo:
This work verifies the impact caused by the Emergencial Program of Reduction of Consumption of Electric Energy (energy-rationing program) in the results of the concessionary private companies of the public service of electric energy distribution localized in the Northeast Area. As the rationing invigorated from June 2001 to February 2002, its effects are diluted in the results presented by these companies in the second semester of 2001 and first quarter of 2002, with prominence for the last quarter of 2001, when the revenue of extraordinary tariff restore was instituted by the National Agency of Electric Energy (ANEEL), consequence of the so-called General Agreement of the Electric Sector made between the federal government and the companies of the electric sector. The structure of a generic electric sector and a historical review of the Brazilian electric sector from the time it was controlled by the private enterprises, including the State control period, about 1960, and returning to the control of the private enterprises in 1990, under a new regulation structure are presented. An explanation of the models of economic regulation that Brazil used for the electric sector is made, with prominence for the price cap that is the actual effective model. The process of tariff revision foreseen in the concession contracts signed by the federal government and the concessionary companies is presented, highlighting its two stages: the tariff rebalancing that defines the new price cap and the calculation of the factor X that establishes the efficiency goals for the companies. There is made a presentation of the Emergencial Program of Reduction of Consumption of Electric Energy and of the consequent General Agreement of the Electric Sector, which created the revenue of extraordinary tariff restore. A conceptual revision on reviews is presented, regarding to concepts, accomplishment and recognition. A brief review of the six companies that made part of the worked sample is also presented. Analyzing the quarters historical review and of amount of sold energy, it was possible to conclude that the energy-rationing altered the results of the studied companies significantly and that alteration was masked by the accounting process of the revenue of extraordinary tariff restore
Resumo:
This work presents contributions in the detection and identication of faults in multilevel inverters through the study of the converters behavior under these operation conditions. Basically, the approached fault consists of an open-circuit in any switch of a three-level clamped diode inverter. The converter operation is characterized in the pre and post-fault states. A wave form behavior analysis of the pole voltage, phase current and dc-bus current is also done, which highlights characteristics that allow the detection of failure and, even, under favorable conditions, the identication of the faulty device. A compensation strategy of the approached fault (open-switch) is also investigated with the purpose of maintaining the driving system operational when a failure occurs. The proposed topology uses SCRs in parallel with the internal switches of the inverter, which allows, in some occasions, the full utilization of the dc-bus
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)