967 resultados para Cancer imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerebral responses to alternating periods of a control task and a selective letter generation paradigm were investigated with functional Magnetic Resonance Imaging (fMRI). Subjects selectively generated letters from four designated sets of six letters from the English language alphabet, with the instruction that they were not to produce letters in alphabetical order either forward or backward, repeat or alternate letters. Performance during this condition was compared with that of a control condition in which subjects recited the same letters in alphabetical order. Analyses revealed significant and extensive foci of activation in a number of cerebral regions including mid-dorsolateral frontal cortex, inferior frontal gyrus, precuneus, supramarginal gyrus, and cerebellum during the selective letter generation condition. These findings are discussed with respect to recent positron emission tomography (PET) and fMRI studies of verbal working memory and encoding/retrieval in episodic memory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PCR-based cancer diagnosis requires detection of rare mutations in k-ras, p53 or other genes. The assumption has been that mutant and wild-type sequences amplify with near equal efficiency, so that they are eventually present in proportions representative of the starting material. Work factor IX suggests that this assumption is invalid for one case of near-sequence identity To test the generality of this phenomenon and its relevance to cancer diagnosis, primers distant from point mutations in p53 and k-ras were used to amplify, wild-type and mutant sequences from these genes. A substantial bias against PCR amplification of mutants was observed for two regions of the p53 gene and one region of k-ras. For kras and p53, bias was observed when the wild-type and mutant sequences were amplified separately or when mixed in equal proportions before PCR. Bias was present with proofreading and non-proofreading polymerases. Mutant and wild-type segments of the factor V cystic fibrosis transmembrane conductance regulator and prothrombin genes were amplified and did not exhibit PCR bias. Therefore, the assumption of equal PCR efficiency for point mutant and wild-type sequences is invalid in several systems. Quantitative or diagnostic PCR will require validation for each locus, and enrichment strategies may be needed to optimize detection of mutants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-three patients treated with intracerebroventricular (ICV) morphine in this study not only obtained excellent pain relief without rapid increases in dose, but also experienced a reduction in morphine-related side effects. By 24 h after initiation of ICV morphine, the mean trough cerebrospinal fluid (CSF) morphine concentration (approximately 20 mu M) was 50-fold higher than the baseline concentration (approximately 0.4 mu M), and the CSF concentration of morphine-6-glucuronide (M6G) was undetectable (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m(2) respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and IO-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias:thigh, -12%; calf, 5%) and adipose tissue (bias:thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20-77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging of the head and neck is the most commonly performed clinical magnetic resonance imaging (MRI) examination [R. G. Evans and J. R. G. Evans, AJR 157, 603 (1991)]. This is usually undertaken in a generalist MRI instrument containing superconducting magnet system capable of imaging all organs. These generalist instruments are large, typically having a bore of 0.9-1.0 m and a length of 1.7-2.5 m and therefore are expensive to site, somewhat claustrophobic to the patient, and offer little access by attending physicians. In this article, we present the design of a compact, superconducting MRI magnet for head and neck imaging that is less than 0.8 m in length and discuss in detail the design of an asymmetric gradient coil set, tailored to the magnet profile. In particular, the introduction of a radio-frequency FM modulation scheme in concert with a gradient sequence allows the epoch of the linear region of the gradient set to be much closer to the end of the gradient structure than was previously possible. Images from a prototype gradient set demonstrate the effectiveness of the designs. (C) 1999 American Institute of Physics. [S0034-6748(99)04910-2].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a three-dimensional scanning probe microscope in which the extremely soft spring of an optical tweezers trap is used. Feedback control of the instrument based on backscattered light levels allows three-dimensional imaging of microscopic samples in an aqueous environment. Preliminary results with a 2-mu m-diameter spherical probe indicate that features of approximately 200 nm can be resolved, with a sensitivity of 5 nm in the height measurement. The theoretical resolution is limited by the probe dimensions. (C) 1999 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To use magnetic resonance imaging (MRI) to validate estimates of muscle and adipose tissue (AT) in lower limb sections obtained by dual-energy X-ray absorptiometry (DXA) modelling. DESIGN: MRI measurements were used as reference for validating limb muscle and AT estimates obtained by DXA models that assume fat-free soft tissue (FFST) comprised mainly muscle: model A accounted for bone hydration only; model B also applied constants for FFST in bone and skin and fat in muscle and AT; model C was as model B but allowing for variable fat in muscle and AT. SUBJECTS: Healthy men (n = 8) and women (n = 8), ages 41 - 62 y; mean (s.d.) body mass indices (BMIs) of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m2, respectively. MEASUREMENTS: MRI scans of the legs and whole body DXA scans were analysed for muscle and AT content of thigh (20 cm) and lower leg (10 cm) sections; 24 h creatinine excretion was measured. RESULTS: Model A overestimated thigh muscle volume (MRI mean, 2.3 l) substantially (bias 0.36 l), whereas model B underestimated it by only 2% (bias 0.045 l). Lower leg muscle (MRI mean, 0.6 l) was better predicted using model A (bias 0.04 l, 7% overestimate) than model B (bias 0.1 l, 17% underestimate). The 95% limits of agreement were high for these models (thigh,+/- 20%; lower leg,+/- 47%). Model C predictions were more discrepant than those of model B. There was generally less agreement between MRI and all DXA models for AT. Measurement variability was generally less for DXA measurements of FFST (coefficient of variation 0.7 - 1.8%) and fat (0.8 - 3.3%) than model B estimates of muscle (0.5-2.6%) and AT (3.3 - 6.8%), respectively. Despite strong relationships between them, muscle mass was overestimated by creatinine excretion with highly variable predictability. CONCLUSION: This study has shown the value of DXA models for assessment of muscle and AT in leg sections, but suggests the need to re-evaluate some of the assumptions upon which they are based.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The estrogen receptor alpha (ER alpha) is implicated in the development of breast cancer. The immunophilins, cyclophilin 40 (CyP40) and FKBP52, are associated with ER alpha and other steroid receptors in mutually exclusive heterocomplexes and may differentially modulate receptor activity. Since previous studies have not assessed the levels of these immunophilins in breast cancer, we examined 10 breast cancer cell lines for mRNA and protein expression of CyP40 and FKBP52 and for amplification of the CyP40 gene. In addition, 26 breast carcinomas, including seven with matched normal breast tissue, were examined for mRNA expression of both immunophilins. CyP40 and FKBP52 were ubiquitously expressed in breast cancer cell lines, but there were significant differences in their pattern of expression. FKBP52 protein levels were generally an order of magnitude greater than those for CyP40. FKBP52 mRNA expression correlated strongly with protein expression and was significantly higher in ER alpha-positive compared with ER alpha-negative cell lines. However, CyP40 mRNA expression did not correlate with protein expression, nor did expression of this immunophilin correlate with ER alpha status. Relatively high expression of CyP40 in one cell line (BT-20) could be attributed to amplification of the CyP40 gene. Both immunophilins were also ubiquitously expressed in breast carcinomas, and we demonstrate for the first time that both CyP40 and FKBP52 mRNA are overexpressed in breast tumors compared to matched normal breast controls. The overexpression of CyP40 and FKBP52, coupled with relative differences in their expression in tumors, may have important functional implications for ER alpha and other steroid receptors in breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a case-control study in three Australian states that included 794 women with epithelial ovarian cancer and 853 community controls for whom we had adequate contraceptive and reproductive histories, Re examined the effects of oral contraceptive use after controlling for estimated number of ovulatory cycles. Other covariates included in the multiple logistic regression analysis were parity, smoking, and history of pelvic surgery. The protective effect of duration of oral contraceptive use appeared to be multiplicative, with a 7% decrease in relative risk per year [95% confidence interval (CI) = 4-9%], persisting beyond 15 years of exposure. Use for up to 1 year may have a greater effect than predicted (odds ratio = 0.57; 95% CI = 0.40-0.82), whereas use before the first pregnancy may be additionally beneficial (odds ratio = 0.95; 95% CI = 0.87-1.03, adjusted for overall duration of use). Better control for ovulatory life might attenuate these estimates somewhat. There was little evidence of waning protection with time since last exposure or of extra benefit with early commencement of oral contraceptive use. We found no convincing evidence of effect modification in any factor examined or differences in effect among the three main histologic cancer types or between borderline and malignant tumors. Oral contraceptives may act by both suppressing ovulation and altering the tumor-promoting milieu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine whether mammographic screening has affected the presentation of invasive breast cancer in Western Australia. Design: Population-based reviews of the presentation of all invasive breast cancers diagnosed in Western Australia in 1989 and 1994. Setting: Western Australia (population 1.8 million), Active recruitment of women aged 50-69 years for mammographic screening began in 1989. Main outcome measures: Size and stage of invasive breast cancers at diagnosis. Results: From 1989 to 1994, the age-standardised incidence rose from 109 to 123 per 100 000 woman-years, based on 584 and 750 cases, respectively. The proportion of all invasive breast cancers detected as a result of a mammogram increased from 9.2% in 1989 to 34.5% in 1994. Among the cases where relevant information was recorded, the proportion of impalpable tumours increased from 7.7% in 1989 to 27.6% in 1994, and the average size of palpable tumours fell. There was an unexpected increase in the proportion of tumours that were negative on assays for oestrogen and progesterone receptors. Conclusions: A relatively simple and inexpensive clinical review has boosted confidence that the outlay of public monies required to establish and conduct screening in Australia appears likely to yield the reductions in mortality from breast cancer that would be predicted on the basis of the earlier controlled trials of mammography.