991 resultados para Body suport device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate body image dissatisfaction and its relationship with physical activity and body mass index in a Brazilian sample of adolescents. Methods: A total of 275 adolescents (139 boys and 136 girls) between the ages of 14 and 18 years completed measures of body image dissatisfaction through the Contour Drawing Scale and current physical activity by the International Physical Activity Questionnaire. Weight and height were also measured for subsequent calculation of body mass index. Results: Boys and girls differed significantly regarding body image dissatisfaction, with girls reporting higher levels of dissatisfaction. Underweight and eutrophic boys preferred to be heavier, while those overweight preferred be thinner and, in contrast, girls desired to be thinner even when they are of normal weight. Conclusion: Body image dissatisfaction was strictly related to body mass index, but not to physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Eletrónica e de Computadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood typing is a crucial step before any blood transfusion. However, sometimes in emergency situations there is no time to determine the blood of the patient beforehand. In this cases, O negative blood type is administered, which has a lesser incompatibility risk to the patient. Nowadays, the “gold standard” blood typing devices cannot be used in emergency situations due to their high response time (about 30 minutes). This paper reports a blood typing device that determines the ABO and Rh human phenotypes. This device is fast (response time – 5 min), low-cost, and portable. Characteristics that make it suitable to be used in emergency situations, contributing to a higher efficiency and quality in healthcare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors acknowledge to Sofia Neves from ICVS for her help in the antibodies selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device embolized to the distal pulmonary bed and, after being rescued with a Bitome, it was appropriately repositioned with no complications and with total occlusion of the vessel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the heart weight and the heart weight/body weight coefficient of adults with and without chronic malnutrition. METHODS: In an initial case series of 210 autopsies performed in adults, we recorded body and heart weights and calculated the heart weight/body weight coefficients (HW/BW x 100). The exclusion criteria were as follows: positive serology for Chagas' disease, edema, obesity, heart diseases, hepatopathies, nephropathies, and systemic arterial hypertension. Malnutrition was characterized as a body mass index <18.5kg/m². Differences with p<0.05 were considered significant. RESULTS: Individuals in the malnourished (n=15) and control (n=21) groups were statistically different, respectively, in regard to body mass index (15.9±1.7 versus 21.3±2.5kg/m²), heart weight (267.3±59.8 versus 329.1±50.4g), and the HW/BW coefficient (0.64±0.12 versus 0.57±0.09%). A positive and significant correlation was observed between heart weight and body mass index (r=0.52), and between heart weight and body weight (r=0.65). CONCLUSION: Malnourished individuals have lighter hearts and a greater HW/BW coefficient than non-malnourished individuals do. These findings indicate a possible preservation of the myocardium in relation to the intensity of weight loss associated with the probable relative increase in cardiac connective tissue and heart blood vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTVE: To objectively and critically assess body mass index and to propose alternatives for relating body weight and height that are evidence-based and that eliminate or reduce the limitations of the body mass index. METHODS: To analyze the relations involving weight and height, we used 2 databases as follows: 1) children and adolescents from Brazil, the United States, and Switzerland; and 2) 538 university students. We performed mathematical simulations with height data ranging from 115 to 190 cm and weight data ranging from 25 to 105 kg. We selected 3 methods to analyze the relation of weight and height as follows: body mass index - weight (kg)/height (m²); reciprocal of the ponderal index - height (cm)/weight1/3 (kg); and ectomorphy. Using the normal range from 20 to 25 kg/m² for the body mass index in the reference height of 170 cm, we identified the corresponding ranges of 41 to 44 cm/kg1/3 for the reciprocal of the ponderal index, and of 1.45 to 3.60 for ectomorphy. RESULTS: The mathematical simulations showed a strong association among the 3 methods with an absolute concordance to a height of 170 cm, but with a tendency towards discrepancy in the normal ranges, which had already been observed for the heights of 165 and 175 cm. This made the direct convertibility between the indices unfeasible. The reciprocal of the ponderal index and ectomorphy with their cut points comprised a larger age range in children and adolescents and a wider and more central range in the university students, both for the reported (current) and desired weights. CONCLUSION: The reciprocal of the ponderal index and ectomorphy are stronger and are more mathematically logical than body mass index; in addition, they may be applied with the same cut points for normal from the age of 5 ½ years on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Med. Fak., Diss., 2014