986 resultados para BREATH FIGURES
Resumo:
BACKGROUND To standardize multiple-breath washout (MBW) measurements, 1L tidal volume (VT) protocols were suggested. The effect on MBW derived ventilation inhomogeneity (VI) indices is unclear. METHODS We compared VI indices from free breathing MBW at baseline to 1L VT MBW performed in triplicates in 35 children (20 with CF). Mean (range) age was 12.8 (7.0-16.7) years, weight 42 (20-64) kg and height 151 (117-170) cm. RESULTS Baseline lung clearance index (LCI) increased from mean (SD) 11.0 (2.2) to 13.0 (2.6), p=0.011, in CF and from 6.8 (0.5) to 7.7 (1.4), p=0.004, in controls. Moment ratio and Scond similarly increased. While change in VI indices was heterogeneous in individuals, decrease in functional residual capacity was most strongly associated with LCI increase. CONCLUSION MBW protocols strongly influence measures of VI. The 1L VT MBW protocol leads to overestimation of VI and is not recommended in children.
Resumo:
Amylase activity in exhaled breath condensate (EBC) is usually interpreted as an indication of oropharyngeal contamination despite the fact that amylase can be found in pulmonary excretions. The aim of this study was to recruit and refine an amylase assay in order to detect amylase activity in any EBC sample and to develop a method to identify EBC samples containing amylase of pulmonary origin. EBC was collected from 40 volunteers with an EcoScreen condenser. Amylase assays and methods to discriminate between oropharyngeal and pulmonary proteins were tested and developed using matched EBC and saliva samples. Our refined 2-chloro-4-nitrophenyl-α-D-maltotriosid (CNP-G3) assay was 40-fold more sensitive than the most sensitive commercial assay and allowed detection of amylase activity in 30 µl of EBC. We developed a dot-blot assay which allowed detection of salivary protein in saliva diluted up to 150 000-fold. By plotting amylase activity against staining intensity we identified a few EBC samples with high amylase activity which were aligned with diluted saliva. We believe that EBC samples aligned with diluted saliva contain amylase activity introduced during EBC collection and that all other EBC samples contain amylase activity of pulmonary origin and are basically free of oropharyngeal protein contamination.
Resumo:
Illustrations are an essential part of most CCS communication materials. This article looks at the role of illustrations in communication and education in general, and in CCS communication in particular. First, literature on multimedia learning is reviewed and general guidelines for designing graphical displays deduced. This is followed by a discussion of relevant mental models and their possible implementa- tion in pictorial form. The authors then report on an interview study in which illustrations with various implementations of CCS mental models are compared. No major differences were found regarding under- standing of CCS between the different illustrations. Graphical displays alone are not powerful enough to implicitly correct typical misconceptions about CCS. Such misconceptions should be stated explicitly, along with their correction.
Resumo:
Objectives Despite many reports on best practises regarding onsite psychological services, little research has attempted to systematically explore the frequency, issues, nature and client groups of onsite sport psychology consultancy at the Olympic Games. The present paper will fill this gap through a systematic analysis of the sport psychology consultancy of the Swiss team for the Olympic Games of 2006 in Turin, 2008 in Beijing and 2010 in Vancouver. Design Descriptive research design. Methods The day reports of the official sport psychologist were analysed. Intervention issues were labelled using categories derived from previous research and divided into the following four intervention-issue dimensions: “general performance”, “specific Olympic performance”, “organisational” and “personal” issues. Data were analysed using descriptive statistics, chi square statistics and odds ratios. Results Across the Olympic Games, between 11% and 25% of the Swiss delegation used the sport psychology services. On average, the sport psychologist provided between 2.1 and 4.6 interventions per day. Around 50% of the interventions were informal interventions. Around 30% of the clients were coaches. The most commonly addressed issues were performance related. An association was observed between previous collaboration, intervention likelihood and intervention theme. Conclusions Sport psychologists working at the Olympic Games are fully engaged with daily interventions and should have developed ideally long-term relationships with clients to truly help athletes with general performance issues. Critical incidents, working with coaches, brief contact interventions and team conflicts are specific features of the onsite consultancy. Practitioners should be trained to deal with these sorts of challenges.
Resumo:
by Gdal Saleski
Resumo:
INTRODUCTION The new ATS/ERS consensus report recommends in vitro validation of multiple-breath inert gas washout (MBW) equipment based on a lung model with simulated physiologic conditions. We aimed to assess accuracy of two MBW setups for infants and young children using this model, and to compare functional residual capacity (FRC) from helium MBW (FRCMBW ) with FRC from plethysmography (FRCpleth ) in vivo. METHODS The MBW setups were based on ultrasonic flow meter technology. Sulfur hexafluoride and helium were used as tracer gases. We measured FRC in vitro for specific model settings with and without carbon dioxide and calculated differences of measured to generated FRC. For in vivo evaluation, difference between FRCMBW and FRCpleth was calculated in 20 healthy children, median age 6.1 years. Coefficient of variation (CV) was calculated per FRC. RESULTS In the infant model (51 runs, FRC 80-300 ml), mean (SD) relative difference between generated and measured FRCs was 0.7 (4.7) %, median CV was 4.4% for measured FRCs. In the young child model, one setting (8 runs, FRC 400 ml) showed a relative difference of up to 13%. For the remaining FRCs (42 runs, FRC 600-1,400 ml), mean (SD) relative difference was -2.0 (3.4) %; median CV was 1.4% for measured FRCs. In vivo FRCpleth exceeded FRCMBW values by 37% on average. CONCLUSIONS Both setups measure lung volumes in the intended age group reliably and reproducibly. Characteristics of different techniques should be considered when measuring lung volumes in vivo. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.
Resumo:
Whereas semantic, logical, and narrative features of verbal humor are well-researched, phonological and prosodic dimensions of verbal funniness are hardly explored. In a 2 × 2 design we varied rhyme and meter in humorous couplets. Rhyme and meter enhanced funniness ratings and supported faster processing. Rhyming couplets also elicited more intense and more positive affective responses, increased subjective comprehensibility and more accurate memory. The humor effect is attributed to special rhyme and meter features distinctive of humoristic poetry in several languages. Verses that employ these formal features make an artful use of typical poetic vices of amateurish poems written for birthday parties or other occasions. Their metrical patterning sounds “mechanical” rather than genuinely “poetic”; they also disregard rules for “good” rhymes. The processing of such verses is discussed in terms of a metacognitive integration of their poetically deviant features into an overall effect of processing ease. The study highlights the importance of nonsemantic rhetorical features in language processing.
Resumo:
BACKGROUND The lung clearance index (LCI) measured by multiple-breath washout (MBW) has been proposed as an outcome for clinical trials; however, MBW is time consuming and LCI can be affected by breathing pattern. We aimed to evaluate moment ratios and abbreviated LCI in school-aged children with mild-to-moderate CF lung disease. METHODS Using existing data from three studies we assessed the sensitivity of moment ratios and abbreviated LCIs to (i) detect mild-to-moderate CF lung disease and (ii) detect treatment effects after 4weeks of hypertonic saline or dornase alfa inhalation. MBW was measured by respiratory mass spectrometry using 4% "sulphur hexafluoride as a tracer gas. RESULTS Compared to the traditional LCI, moment ratios and abbreviated LCIs were similarly sensitive to detect CF lung disease. Moment ratios consistently demonstrated treatment effects, whereas abbreviated LCIs were less sensitive. CONCLUSIONS Both moment ratios and abbreviated LCI are suitable to differentiate health from disease. Sensitivity is decreased for abbreviated LCIs in interventional studies in mild CF lung disease.