947 resultados para BLOOD-FLOW RESISTANCE
Resumo:
Passive tilting increases ventilation in healthy subjects; however, controversy surrounds the proposed mechanism. This study is aimed to evaluate the possible mechanism for changes to ventilation following passive head-up tilt (HUT) and active standing by comparison of a range of ventilatory, metabolic and mechanical parameters. Ventilatory parameters (V (T), V (E), V (E)/VO2, V (E)/VCO2, f and PetCO(2)), functional residual capacity (FRC), respiratory mechanics with impulse oscillometry; oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in 20 healthy male subjects whilst supine, following HUT to 70 degrees and unsupported standing. Data were analysed using a linear mixed model. HUT to 70 degrees from supine increased minute ventilation (V (E)) (P < 0.001), tidal volume (V (T)) (P=0.001), ventilatory equivalent for O-2 (V (E)/VO2) (P=0.020) and the ventilatory equivalent for CO2 (V (E)/VCO2) (P < 0.001) with no change in f (P=0.488). HUT also increased FRC (P < 0.001) and respiratory system reactance (X5Hz) (P < 0.001) with reduced respiratory system resistance (R5Hz) (P=0.004) and end-tidal carbon dioxide (PetCO(2)) (P < 0.001) compared to supine. Standing increased V (E) (P < 0.001), V (T) (P < 0.001) and V (E)/VCO2 (P=0.020) with no change in respiratory rate (f) (P=0.065), V (E)/VO2 (P=0.543). Similar changes in FRC (P < 0.001), R5Hz (P=0.013), X5Hz (P < 0.001) and PetCO(2) (P < 0.001) compared to HUT were found. In contrast to HUT, standing increased VO2 (P=0.002) and VCO2 (P=0.048). The greater increase in V (E) in standing compared to HUT appears to be related to increased VO2 and VCO2 associated with increased muscle activity in the unsupported standing position. This has implications for exercise prescription and rehabilitation of critically ill patients who have reduced cardiovascular and respiratory reserve.
Resumo:
The nongenomic effects of aldosterone in disease states associated with endothelial dysfunction may differ from those in healthy subjects. The effects of locally infused aldosterone on the forearm blood flow and volume were studied in optimally treated patients with chronic heart failure (CHF). At baseline and after incremental intrabrachial aldosterone, forearm blood flow was assessed using conventional strain gouge plethysmography, and forearm venous volume was assessed by radionuclide plethysmography. Constriction of the resistance vasculature of the forearm without significant effect on forearm venous capacitance was demonstrated in response to aldosterone in patients treated for CHF. (C) 2005 by Excerpta Medica Inc.
Resumo:
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
Resumo:
The flow behaviour of shallow gas-fluidised beds was studied. experimentally using a rotational viscometer, and an inclined open channel. Initially, tests were carried out with the viscometer in order to establish qualitative trends in the flow properties of a variety of materials over a wide range of fluidising conditions. Also, a technique was developed which enabled quantitative viscosity data to be extracted from the experimental results. The flow properties were found to be sensitive to the size, size-range and density of the fluidised material, the type of distributor used, and the moisture content of the fluidising gas. Tests in beds up to 120 mm deep showed that the fluidity of the bed improves with reduction in depth; and indicated a range of flow behaviour from shear-thinning to Newtonian, depending chiefly on fluidising velocity .. Later, an apparatus was built which provided for a steady, continuous flow of fluidised material down an inclined open channel of 3m length x 0.15m square, up to a mass flowrate of 10 kg/s (35 ton/hr). This facility has enabled data to be obtained that is of practical value in industrial applications; which is otherwise difficult in view of the present limited understanding of the true mechanism of fluidised flow. A correlation has been devised, based on analogy with laminar liquid flow, which describes the channel flow behaviour with reasonable accuracy over the whole range of shear-rates used. 1he channeI results indicated that at low fluidiising velocities the flow was adversely affected by settlement of a stagnant layer of particles on to the distributor, which gave rise to increased flow resistance. Conversely, at higher fluidising velocities the resistance at the distributor appeared to be less than at the walls. In view of this, and also because of the disparity in shear-rates between the two types of apparatus, it is not possible as yet to predict exactly the flow behaviour in an open channel from small-scale viscometer tests.
Resumo:
Cardiovascular diseases (CVD) contributed to almost 30% of worldwide mortality; with heart failure being one class of CVD. One popular and widely available treatment for heart failure is the intra-aortic balloon pump (IABP). This heart assist device is used in counterpulsation to improve myocardial function by increasing coronary perfusion, and decreasing aortic end-diastolic pressure (i.e. the resistance to blood ejection from the heart). However, this device can only be used acutely, and patients are bedridden. The subject of this research is a novel heart assist treatment called the Chronic Intermittent Mechanical Support (CIMS) which was conceived to offer advantages of the IABP device chronically, whilst overcoming its disadvantages. The CIMS device comprises an implantable balloon pump, a percutaneous drive line, and a wearable driver console. The research here aims to determine the haemodynamic effect of balloon pump activation under in vitro conditions. A human mock circulatory loop (MCL) with systemic and coronary perfusion was constructed, capable of simulating various degrees of heart failure. Two prototypes of the CIMS balloon pump were made with varying stiffness. Several experimental factors (balloon inflation/deflation timing, Helium gas volume, arterial compliance, balloon pump stiffness and heart valve type) form the factorial design experiments. A simple modification to the MCL allowed flow visualisation experiments using video recording. Suitable statistical tests were used to analyse the data obtained from all experiments. Balloon inflation and deflation in the ascending aorta of the MCL yielded favourable results. The sudden balloon deflation caused the heart valve to open earlier, thus causing longer valve opening duration in a cardiac cycle. It was also found that pressure augmentation in diastole was significantly correlated with increased cardiac output and coronary flowrate. With an optimum combination (low arterial compliance and low balloon pump stiffness), systemic and coronary perfusions were increased by 18% and 21% respectively, while the aortic end-diastolic pressure (forward flow resistance) decreased by 17%. Consequently, the ratio of oxygen supply and demand to myocardium (endocardial viability ratio, EVR) increased between 33% and 75%. The increase was mostly attributed to diastolic augmentation rather than systolic unloading.
Resumo:
The knowledge of insulation debris generation and transport gains in importance regarding reactor safety research for PWR and BWR. The insulation debris released near the break consists of a mixture of very different fibres and particles concerning size, shape, consistence and other properties. Some fraction of the released insulation debris will be transported into the reactor sump where it may affect emergency core cooling. Experiments are performed to blast original samples of mineral wool insulation material by steam under original thermal-hydraulic break conditions of BWR. The gained fragments are used as initial specimen for further experiments at acrylic glass test facilities. The quasi ID-sinking behaviour of the insulation fragments are investigated in a water column by optical high speed video techniques and methods of image processing. Drag properties are derived from the measured sinking velocities of the fibres and observed geometric parameters for an adequate CFD modelling. In the test rig "Ring line-II" the influence of the insulation material on the head loss is investigated for debris loaded strainers. Correlations from the filter bed theory are adapted with experimental results and are used to model the flow resistance depending on particle load, filter bed porosity and parameters of the coolant flow. This concept also enables the simulation of a particular blocked strainer with CFDcodes. During the ongoing work further results of separate effect and integral experiments and the application and validation of the CFD-models for integral test facilities and original containment sump conditions are expected.
Resumo:
Surface water flow patterns in wetlands play a role in shaping substrates, biogeochemical cycling, and ecosystem characteristics. This paper focuses on the factors controlling flow across a large, shallow gradient subtropical wetland (Shark River Slough in Everglades National Park, USA), which displays vegetative patterning indicative of overland flow. Between July 2003 and December 2007, flow speeds at five sites were very low (s−1), and exhibited seasonal fluctuations that were correlated with seasonal changes in water depth but also showed distinctive deviations. Stepwise linear regression showed that upstream gate discharges, local stage gradients, and stage together explained 50 to 90% of the variance in flow speed at four of the five sites and only 10% at one site located close to a levee-canal combination. Two non-linear, semi-empirical expressions relating flow speeds to the local hydraulic gradient, water depths, and vegetative resistance accounted for 70% of the variance in our measured speed. The data suggest local-scale factors such as channel morphology, vegetation density, and groundwater exchanges must be considered along with landscape position and basin-scale geomorphology when examining the interactions between flow and community characteristics in low-gradient wetlands such as the Everglades.
Resumo:
Microcirculatory vessels are lined by endothelial cells (ECs) which are surrounded by a single or multiple layer of smooth muscle cells (SMCs). Spontaneous and agonist induced spatiotemporal calcium (Ca2+) events are generated in ECs and SMCs, and regulated by complex bi-directional signaling between the two layers which ultimately determines the vessel tone. The contractile state of microcirculatory vessels is an important factor in the determination of vascular resistance, blood flow and blood pressure. This dissertation presents theoretical insights into some of the important and currently unresolved phenomena in microvascular tone regulation. Compartmental and continuum models of isolated EC and SMC, coupled EC-SMC and a multi-cellular vessel segment with deterministic and stochastic descriptions of the cellular components were developed, and the intra- and inter-cellular spatiotemporal Ca2+ mobilization was examined. Coupled EC-SMC model simulations captured the experimentally observed localized subcellular EC Ca2+ events arising from the opening of EC transient receptor vanilloid 4 (TRPV4) channels and inositol triphosphate receptors (IP3Rs). These localized EC Ca2+ events result in endothelium-derived hyperpolarization (EDH) and Nitric Oxide (NO) production which transmit to the adjacent SMCs to ultimately result in vasodilation. The model examined the effect of heterogeneous distribution of cellular components and channel gating kinetics in determination of the amplitude and spread of the Ca2+ events. The simulations suggested the necessity of co-localization of certain cellular components for modulation of EDH and NO responses. Isolated EC and SMC models captured intracellular Ca2+ wave like activity and predicted the necessity of non-uniform distribution of cellular components for the generation of Ca2+ waves. The simulations also suggested the role of membrane potential dynamics in regulating Ca2+ wave velocity. The multi-cellular vessel segment model examined the underlying mechanisms for the intercellular synchronization of spontaneous oscillatory Ca2+ waves in individual SMC. From local subcellular events to integrated macro-scale behavior at the vessel level, the developed multi-scale models captured basic features of vascular Ca2+ signaling and provide insights for their physiological relevance. The models provide a theoretical framework for assisting investigations on the regulation of vascular tone in health and disease.
Resumo:
Computational fluid dynamic (CFD) studies of blood flow in cerebrovascular aneurysms have potential to improve patient treatment planning by enabling clinicians and engineers to model patient-specific geometries and compute predictors and risks prior to neurovascular intervention. However, the use of patient-specific computational models in clinical settings is unfeasible due to their complexity, computationally intensive and time-consuming nature. An important factor contributing to this challenge is the choice of outlet boundary conditions, which often involves a trade-off between physiological accuracy, patient-specificity, simplicity and speed. In this study, we analyze how resistance and impedance outlet boundary conditions affect blood flow velocities, wall shear stresses and pressure distributions in a patient-specific model of a cerebrovascular aneurysm. We also use geometrical manipulation techniques to obtain a model of the patient’s vasculature prior to aneurysm development, and study how forces and stresses may have been involved in the initiation of aneurysm growth. Our CFD results show that the nature of the prescribed outlet boundary conditions is not as important as the relative distributions of blood flow through each outlet branch. As long as the appropriate parameters are chosen to keep these flow distributions consistent with physiology, resistance boundary conditions, which are simpler, easier to use and more practical than their impedance counterparts, are sufficient to study aneurysm pathophysiology, since they predict very similar wall shear stresses, time-averaged wall shear stresses, time-averaged pressures, and blood flow patterns and velocities. The only situations where the use of impedance boundary conditions should be prioritized is if pressure waveforms are being analyzed, or if local pressure distributions are being evaluated at specific time points, especially at peak systole, where the use of resistance boundary conditions leads to unnaturally large pressure pulses. In addition, we show that in this specific patient, the region of the blood vessel where the neck of the aneurysm developed was subject to abnormally high wall shear stresses, and that regions surrounding blebs on the aneurysmal surface were subject to low, oscillatory wall shear stresses. Computational models using resistance outlet boundary conditions may be suitable to study patient-specific aneurysm progression in a clinical setting, although several other challenges must be addressed before these tools can be applied clinically.
Resumo:
The walls of blood vessels are lined with a single-cell layer of endothelial cells. As blood flows through the arteries, a frictional force known as shear stress is sensed by mechanosensitive structures on the endothelium. Short and long term changes in shear stress can have a significant influence on the regulation of endothelial function. Acutely, shear stress triggers a pathway that culminates in the release of vasodilatory molecules from the endothelium and subsequent vasodilation of the artery. This endothelial response is known as flow mediated dilation (FMD). FMD is used as an index of endothelial function and is commonly assessed using reactive hyperemia (RH)-FMD, a method which elicits a large, short lived increase in shear stress following the release of a brief (5 min) forearm occlusion. A recent study found that a short term exposure (30 min) to a sustained elevation in shear stress potentiates subsequent RH-FMD. FMD can also result from a more prolonged, sustained increase in shear stress elicited by handgrip exercise (HGEX-FMD). There is evidence to suggest that interventions and conditions impact FMD resulting from sustained and transient shear stress stimuli differently, indicating that HGEX-FMD and RH-FMD provide different information about endothelial function. It is unknown whether HGEX-FMD is improved by short term exposure to shear stress. Understanding how exercise induced FMD is regulated is important because it contributes to blood flow responses during exercise. The study purpose was therefore to assess the impact of a handgrip exercise (intervention) induced sustained elevation in shear stress on subsequent brachial artery (BA) HGEX-FMD. Twenty healthy male participants (22±3yrs) preformed a 30-minute HGEX intervention on two experimental days. BA-FMD was assessed using either an RH or HGEX shear stress stimulus at 3 time points: pre-intervention, 10 min post and 60 min post. FMD and shear stress magnitude were determined via ultrasound. Both HGEX and RH-FMD increased significantly from pre-intervention to 10 min-post (p<0.01). These findings indicate that FMD stimulated by exercise induced increases in shear stress is potentiated by short term shear stress exposure. These findings advance our understanding regarding the regulation of endothelial function by shear stress.
Resumo:
The endothelium is the inner most layer of cells that lines all arteries. A primary function of endothelial cells is to regulate responses to increased blood flow and the resulting frictional forces or shear stress by producing factors such as nitric oxide that mediate arterial dilation (flow mediated dilation (FMD)). Menstrual cycle variations in estrogen (E2) have been shown to influence brachial artery (BA) FMD in response to transient increases in shear stress brought about by the release of a brief forearm occlusion (reactive hyperemia (RH)). FMD can also be assessed in response to a sustained shear stress stimulus such as that created with handgrip exercise (HGEX), and studies have shown that RH- and HGEX stimulated FMD provide unique information regarding endothelial function. However, the impact of menstrual phase on HGEX-FMD is unknown. Therefore, the purpose of this study was to determine the impact of cyclical changes in E2 levels on HGEX-FMD over two discrete phases of the menstrual cycle. FMD was assessed via ultrasound. 12 subjects (21 ± 2yrs) completed two experimental visits: (1) low estrogen phase (early follicular) and (2) High estrogen phase (late follicular). In each visit both RH- and HGEX-FMD (6 min handgrip exercise) were assessed. Results are mean ± SD. E2 increased from the low to the high estrogen phase of the menstrual cycle (low: 34 ± 8, high: 161 ± 113pg/mL, p = 0.004). There was no change in mean FMD between phases (RH-FMD: 7.7 ± 4.3% vs. 6.4 ± 3.1%, p = 0.139; HGEX-FMD: 4.8 ± 2.8% vs. 4.8 ± 2.3%, p = 0.979). The observation that both RH- and HGEX-FMD did not differ between phases indicates that menstrual cycle fluctuations in estrogen may not universally impact endothelial function in young, healthy premenopausal women. Further research is needed to improve our understanding of the mechanisms that underlie variability in the impact of menstrual phase on both transient and sustained FMD responses.
Resumo:
L’hypertension artérielle pulmonaire (HTAP) est une maladie caractérisée par l’augmentation progressive des résistances vasculaires pulmonaires causant une augmentation de la pression artérielle pulmonaire qui mène au décès prématuré des patients. Malgré une amélioration rapide ces dernières années des traitements spécifiques, les patients souffrant d’HTAP demeurent dyspnéiques et intolérants à l’effort. L’atteinte vasculaire pulmonaire est actuellement irréversible. Elle est également la source de plusieurs anomalies au niveau des systèmes cardiovasculaires, ventilatoires et musculaires constituant les principaux déterminants physiologiques de la capacité à l’effort des patients. Cette thèse a investigué différentes facettes de la tolérance à l’effort en HTAP : les différents mécanismes ayant un impact sur l’apport musculaire en oxygène, l’altération des voies de signalisation cellulaire impliquées dans l’angiogenèse musculaire et les mécanismes ayant un impact sur la régulation du débit sanguin et l’oxygénation cérébrale en HTAP. Nous avons premièrement documenté une diminution de l’apport en oxygène aux muscles squelettiques à l’effort des patients en relation avec une diminution de la densité capillaire musculaire. Ce défaut d’angiogenèse corrélait d’ailleurs avec la capacité à l’effort des sujets. Par la suite, nous avons étudié les voies de signalisations cellulaires de l’angiogenèse musculaire. Ces résultats ont permis de démontrer une diminution de l’expression de miR-126, unique aux patients HTAP, qui était responsable de la diminution de la densité capillaire et qui contribuait à leur intolérance à l’effort. De plus, il était possible de moduler in vivo l’expression de miR-126. L’expérimentation in vivo, à l’aide d’un modèle murin d’HTAP, a permis de rétablir l’expression de miR-126, d’augmenter la microcirculation musculaire et d’améliorer la tolérance à l’effort des animaux, ce qui met en lumière le potentiel thérapeutique de l’angiogenèse musculaire pour améliorer la capacité à l’effort en HTAP. Notre dernier projet a démontré que les patients HTAP présentaient une diminution de débit sanguin cérébral. Ce projet a également démontré que les changements de pression artérielle sont moins bien amortis par les vaisseaux cérébraux des patients et que leurs vaisseaux cérébraux étaient moins réactifs aux changements de CO2. Les patients présentaient aussi une augmentation de la sensibilité des chémorécepteurs centraux qui contribuait à augmenter leur ventilation au repos, mais aussi à l’exercice. Finalement, à l’effort, nous avons démontré que le débit sanguin cérébral des patients HTAP était principalement influencé par la pression artérielle alors que chez les sujets sains, le débit sanguin cérébral était influencé principalement par la PETCO2. Nous avons également démontré que les patients HTAP présentaient une diminution progressive de leur oxygénation cérébrale, qui corrélait avec leur capacité à l’effort. Les résultats obtenus au cours de ce doctorat démontrent bien que la capacité à l’effort en HTAP est aussi déterminée par plusieurs anomalies physiopathologiques périphériques.
Resumo:
Amphetamine enhances recovery after experimental ischaemia and has shown promise in small clinical trials when combined with motor or sensory stimulation. Amphetamine, a sympathomimetic, might have haemodynamic effects in stroke patients, although limited data have been published. Subjects were recruited 3-30 days post ischaemic stroke into a phase II randomised (1:1), double blind, placebo-controlled trial. Subjects received dexamphetamine (5mg initially, then 10mg for 10 subsequent doses with 3 or 4 day separations) or placebo in addition to inpatient physiotherapy. Recovery was assessed by motor scales (Fugl-Meyer, FM), and functional scales (Barthel index, BI and modified Rankin score, mRS). Peripheral blood pressure (BP), central haemodynamics and middle cerebral artery blood flow velocity were assessed before, and 90 minutes after, the first 2 doses. 33 subjects were recruited, age 33-88 (mean 71) years, males 52%, 4-30 (median 15) days post stroke to inclusion. 16 patients were randomised to placebo and 17 amphetamine. Amphetamine did not improve motor function at 90 days; mean (standard deviation) FM 37.6 (27.6) vs. control 35.2 (27.8) (p=0.81). Functional outcome (BI, mRS) did not differ between treatment groups. Peripheral and central systolic BP, and heart rate, were 11.2 mmHg (p=0.03), 9.5 mmHg (p=0.04) and 7 beats/minute (p=0.02) higher respectively with amphetamine, compared with control. A non-significant reduction in myocardial perfusion (Buckberg Index) was seen with amphetamine. Other cardiac and cerebral haemodynamics were unaffected. Amphetamine did not improve motor impairment or function after ischaemic stroke but did significantly increase BP and heart rate without altering cerebral haemodynamics.
Resumo:
Since identification that mutations in NOTCH3 are responsible for cerebral autosomal dominant arteriopathy with subcortical infarcts and leucoencephalopathy (CADASIL) in the early 1990s, there has been extensive characterisation of the clinical and radiological features of the disease. However therapeutic interventions remain elusive, partly due to a limited understanding of the vascular pathophysiology and how it leads to the development of strokes, cognitive decline and disability. The apparent rarity and heterogenous natural history of CADASIL potentially make conducting any longitudinal or therapeutic trials difficult. The role of disease biomarkers is therefore of some interest. This thesis focuses on vascular function in CADASIL and how it may relate to clinical and radiological markers of disease. Establishing the prevalence of CADASIL in the West of Scotland was important to assess the impact of the disease, and how feasible a trial would be. A mutation prevalence of 10.7 per 100,000 was demonstrated, suggesting significant under diagnosis of the disease across much of Scotland. Cerebral hypoperfusion is thought to be important in CADASIL, and it has been shown that vascular abnormalities precede the development of brain pathology in mouse models. Investigation of vascular function in patients, both in the brain and systemically, requires less invasive measures. Arterial spin labelling magnetic resonance imaging (MRI) and transcranial Doppler ultrasound (TCD) can both be used to obtain non-invasive and quantifiable indices of vascular function. Monitoring patients with MRI whilst they receive different concentrations of inspired oxygen and carbon dioxide can provide information on brain function, and I reviewed the practicalities of this technique in order to guide the design of the studies in this thesis. 22 CADASIL patients were recruited to a longitudinal study. Testing included peripheral vascular assessment, assessment of disability, neurological dysfunction, mood and cognition. A CO2 reactivity challenge during both TCD and arterial spin labelling MRI, and detailed MRI sequences were obtained. I was able to demonstrate that vasoreactivity was associated with the number of lacunes and brain atrophy, as were carotid intima-media thickness, vessel stiffness, and age. Patients with greater disability, higher depressive symptoms and poorer processing speed showed a tendency to worse cerebral vasoreactivity but numbers were small. This observation suggests vasoreactivity may have potential as a therapeutic target, or a biomarker. I then wished to establish if arterial spin labelling MRI was useful for assessing change in cerebral blood flow in CADASIL patients. Cortical grey matter showed the highest blood flow, mean (SD), 55 (10) ml/100g/min and blood flow was significantly lower within hyperintensities (19 (4) ml/100g/min; p <0.001). Over one year, blood flow in both grey matter (mean -7 (10) %; p = 0.028) and deep white matter (-8 (13) %; p = 0.036) declined significantly. Cerebrovascular reactivity did not change over one year. I then investigated whether baseline vascular markers were able to predict change in radiological or neuropsychological measures of disease. Changes in brain volume, lacunes, microbleeds and normalised subcortical hyperintensity volume (increase of 0.8%) were shown over one year. Baseline vascular parameters were not able to predict these changes, or those in neuropsychological testing. NOTCH3 is found throughout the body and a systemic vasculopathy has been seen particularly affecting resistance vessels. Gluteal biopsies were obtained from 20 CADASIL patients, and ex vivo myography investigated the response to vasoactive agents. Evidence of impairment in both vasodilation and vasoconstriction was shown. The addition of antioxidants improved endothelium-dependent relaxation, indicating a role for oxidative stress in CADASIL pathology. Myography measures were not related to in vivo measures in the sub-group of patients who had taken part in both studies. The small vessels affected in CADASIL are unable to be imaged by conventional MR imaging so I aimed to establish which vessels might be responsible for lacunes with use of a microangiographic template overlaid onto brain images registered to a standard brain template. This showed most lacunes are small and associated with tertiary arterioles. On the basis of this thesis, it is concluded that vascular dysfunction plays an important role in the pathophysiology of CADASIL, and further assessment of vascular measures in longitudinal studies is needed. Arterial spin labelling MRI should be used as it is a reliable, non-invasive modality that can measure change over one year. Furthermore conventional cardiovascular risk factor prevention should be undertaken in CADASIL patients to delay the deleterious effects of the disease.
Resumo:
Changes in red blood cell (RBC) function can contribute to alterations in microcirculatory blood flow and cellular dysoxia in sepsis. Decreases in RBC and neutrophil deformability impair the passage of these cells through the microcirculation. While the role of leukocytes has been the focus of many studies in sepsis, the role of erythrocyte rheological alterations in this syndrome has only recently been investigated. RBC rheology can be influenced by many factors, including alterations in intracellular calcium and adenosine triphosphate (ATP) concentrations, the effects of nitric oxide, a decrease in some RBC membrane components such as sialic acid, and an increase in others such as 2,3 diphosphoglycerate. Other factors include interactions with white blood cells and their products (reactive oxygen species), or the effects of temperature variations. Understanding the mechanisms of altered RBC rheology in sepsis, and the effects on blood flow and oxygen transport, may lead to improved patient management and reductions in morbidity and mortality.