980 resultados para Anticorpo antitransglutaminase tecidual IgA
Resumo:
Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies
Resumo:
O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.
Resumo:
A Salmonella é um microrganismo responsável por grande parte das doenças alimentares, podendo por em causa a saúde pública da área contaminada. Uma deteção rápida, eficiente e altamente sensível e extremamente importante, sendo um campo em franco desenvolvimento e alvo de variados e múltiplos estudos na comunidade cientifica atual. Foi desenvolvido um método potenciométrico para a deteção de Salmonellas, com elétrodos seletivos de iões, construídos em laboratório com pontas de micropipetas, fios de prata e sensores com composição otimizada. O elétrodo indicador escolhido foi um ESI seletivo a cadmio, para redução da probabilidade de interferências no método, devido a pouca abundancia do cadmio em amostras alimentares. Elétrodos seletivos a sódio, elétrodos de Ag/AgCl de simples e de dupla juncão foram também construídos e caracterizados para serem aplicados como elétrodos de referência. Adicionalmente otimizaram-se as condições operacionais para a analise potenciométrica, nomeadamente o elétrodo de referencia utilizado, condicionamento dos elétrodos, efeito do pH e volume da solução amostra. A capacidade de realizar leituras em volumes muito pequenos com limites de deteção na ordem dos micromolares por parte dos ESI de membrana polimérica, foi integrada num ensaio com um formato nao competitivo ELISA tipo sanduiche, utilizando um anticorpo primário ligado a nanopartículas de Fe@Au, permitindo a separação dos complexos anticorpo-antigénio formados dos restantes componentes em cada etapa do ensaio, pela simples aplicação de um campo magnético. O anticorpo secundário foi marcado com nanocristais de CdS, que são bastante estáveis e é fácil a transformação em Cd2+ livre, permitindo a leitura potenciométrica. Foram testadas várias concentrações de peroxido de hidrogénio e o efeito da luz para otimizar a dissolução de CdS. O método desenvolvido permitiu traçar curvas de calibração com soluções de Salmonellas incubadas em PBS (pH 4,4) em que o limite de deteção foi de 1100 CFU/mL e de 20 CFU/mL, utilizando volumes de amostra de 10 ƒÊL e 100 ƒÊL, respetivamente para o intervalo de linearidade de 10 a 108 CFU/mL. O método foi aplicado a uma amostra de leite bovino. A taxa de recuperação media obtida foi de 93,7% } 2,8 (media } desvio padrão), tendo em conta dois ensaios de recuperação efetuados (com duas replicas cada), utilizando um volume de amostra de 100 ƒÊL e concentrações de 100 e 1000 CFU/mL de Salmonella incubada.
Resumo:
The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.
Resumo:
O cancro é uma das principais causas de morte em todo o mundo. Entre as mulheres, o cancro da mama é o mais frequente. A deteção precoce do cancro é de extrema importância na medida em que pode aumentar as possibilidades de cura dos pacientes e contribuir para a diminuição da taxa de mortalidade desta doença. Um método que tem contribuído para a deteção precoce do cancro é a análise de biomarcadores. Biomarcadores associados ao cancro da mama, como o Recetor 2 do Fator de Crescimento Epidérmico Humano (HER2) e o Antigénio Carbohidratado 15-3 (CA 15-3), podem ser detetados através de dispositivos como os biossensores. Neste trabalho foram desenvolvidos dois imunossensores eletroquímicos para a análise de HER2 e CA 15-3. Para ambos os sensores foram utilizados, como transdutores, elétrodos serigrafados de carbono. A superfície destes transdutores foi nanoestruturada com nanopartículas de ouro. Foram realizados imunoensaios não-competitivos (do tipo sandwich) em ambos os imunossensores, cuja estratégia consistiu na (i) imobilização do respetivo anticorpo de captura na superfície nanoestruturada dos elétrodos, (ii) bloqueio da superfície com caseína, (iii) incubação com uma mistura do analito (HER2 ou CA 15-3) e o respetivo anticorpo de deteção biotinilado, (iv) adição de estreptavidina conjugada com fosfatase alcalina (S-AP; a AP foi utilizada como marcador enzimático), (v) adição de uma mistura do substrato enzimático (3-indoxil fosfato) e nitrato de prata, e (vi) deteção do sinal analítico através da redissolução anódica, por voltametria de varrimento linear, da prata depositada enzimaticamente. Com as condições experimentais otimizadas, foi estabelecida a curva de calibração para a análise de HER2 em soro, entre 15 e 100 ng/mL, obtendo-se um limite de deteção de 4,4 ng/mL. Para o CA 15-3 a curva de calibração (em solução aquosa) foi estabelecida entre 15 e 250 U/mL, obtendo-se um limite de deteção de 37,5 U/mL. Tendo em conta o valor limite (cutoff value) estabelecido para o HER2 (15 ng/mL) pode-se comprovar a possível utilidade do imunossensor desenvolvido para o diagnóstico precoce e descentralizado do cancro da mama. No caso do CA 15-3 serão necessários estudos adicionais para se poder avaliar a utilidade do imunossensor para o diagnóstico do cancro da mama.
Resumo:
Leptospirosis severity may be increasing, with pulmonary involvement becoming more frequent. Does this increase result from an intense immune response to leptospire? Notice that renal failure, thrombocytopenia and pulmonary complications are found during the immune phase. Thirty-five hospitalized patients with Weil's disease had 5 blood samples drawn, from the 15th day to the 12th month of symptoms, for ELISA-IgM, -IgG and -IgA specific antibody detection. According their 1st IgG titer, the patients were divided into: group 1 (n = 13) titer > 1:400 (positive) and group 2 (n = 22) titer <=1:400 (negative). Early IgG antibodies in group 1 showed high avidity which may indicate reinfection. Group 1 was older, had worse pulmonary and renal function, and fever for a longer period than group 2. Throughout the study, IgG and IgA titers remained higher in group 1. In conclusion, the severity of Weil's disease may be associated with the intensity of the humoral immune response to leptospire.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
A Granulomatose de Wegener é uma doença sistémica de etiologia desconhecida, caracterizada pela tríade clínica: envolvimento da mucosa nasal e dos seios perinasais, infiltração e cavitação pulmonar e doença renal com hematúria. A Granulomatose de Wegener afecta normalmente adultos jovens e de meia idade e embora seja incomum nas crianças, pode surgir em qualquer estrato etário. Apresentamos o caso clínico de uma adolescente de 14 anos, com sintomas de epistaxis, cuja investigação posterior mostrou insuficiência renal e múltiplos nódulos pulmonares. O teste positivo para o anticorpo antineutrofílico citoplasmático suportou o diagnóstico de Granulomatose de Wegener, necessitando de terapêutica com hemodiálise e imunossupressão.
Resumo:
Os autores apresentam o caso clínico de uma criança de 18 meses, sexo masculino, raça branca,internada na Unidade de Nefrologia com o diagnóstico de síndroma nefrótico - crise inaugural. Atendendo à idade, aos parâmetros bioquímicos e estudo imunológico negativo, admite-se síndroma nefrótico de lesões mínimas e inicia corticoterapia na dose 60mg/m2/dia. Porqua às seis semanas mantinha edema refractário e comportava-se como corticorresistente, efectuou-se biópsia renal que revelou glomerunefrite membranosa com profileração de crescentes depósitos de IgG, IgA, IgM, C1, C3, C4, C1q, a favor da doença imunológica de base e sugestiva de nefropatia lúpica. O protocolo terapêutico foi revisto e iniciou terapêutica de seis ciclos mensais de ciclofosfamida endovenosa. A resposta clínica laboratorial foi favorável a partir do quarto ciclo e está em remissão após os seis ciclos efectuados e seguimento em ambulatório de 14 meses.
Resumo:
Introdução: As soluções reconstrutivas das queimaduras dos membros inferiores com exposição óssea (transferência de tecidos vascularizados) e dos defeitos do escalpe, não susceptíveis de encerramento com retalhos locais (expansão tecidual), são complexas, morosas e, por vezes, inviáveis. O recurso a substitutos cutâneos biológicos, como a matriz de regeneração dérmica, constitui uma importante alternativa às soluções reconstrutivas tradicionais. Relato dos casos: Estudo retrospectivo de 246 doentes com queimaduras dos membros inferiores, admitidos na Unidade de Queimados/Serviço de Cirurgia Plástica do nosso Centro Hospitalar, entre Janeiro de 2007 e Dezembro de 2008. Os autores apresentam 2 casos clínicos com queimaduras bilaterais das pernas e com exposição óssea. Nos dois casos, realizou-se desbridamento tangencial e encerramento das áreas cruentas com um substituto cutâneo, a matriz de regeneração dérmica. Na 4ª semana após a aplicação da matriz, o componente externo da membrana bilaminar foi substituído por enxerto de pele parcial. Obteve-se cobertura estável das áreas cruentas, sem necessidade de procedimentos cirúrgicos adicionais. Conclusões: A utilização de substitutos dérmicos expande as opções reconstrutivas nos casos de queimaduras com exposição óssea dos membros inferiores. A utilização da matriz biológica permitiu a preservação dos membros nos dois pacientes. A matriz de regeneração dérmica possibilitou uma cobertura estável de estruturas vitais, sem necessidade de transferência ou expansão tecidual e com morbilidade mínima.
Resumo:
Herein we have described the case of a male renal transplant recipient who developed drug fever apparently related to sirolimus. He had been stable under an immunosuppressive regimen of tacrolimus and mycophenolate mofetil, but developed acute cellular rejection at 5 years after transplantation due to noncompliance. Renal biopsy showed marked interstitial fibrosis, and immunosuppression was switched from mycophenolate to sirolimus, maintaining low tacrolimus levels. One month later he was admitted to our hospital for investigation of intermittently high fever, fatigue, myalgias, and diarrhea. Physical examination was unremarkable and drug levels were not increased. Lactic dehydrogenase and C-reactive protein were increased. The blood cell count and chest radiographic findings were normal. After extensive cultures, he was started on broad-spectrum antibiotics. Inflammatory markers and fever worsened, but diarrhea resolved. All serologic and imaging tests excluded infection, immune-mediated diseases, and malignancy. After 12 days antibiotics were stopped as no clinical improvement was achieved. Drug fever was suspected; sirolimus was replaced by mycophenolate mofetil. Fever and other symptoms disappeared after 24 hours; inflammatory markers normalized in a few days. After 1 month the patient was in good health with stable renal function. Although infrequent, the recognition of drug fever as a potential side effect of sirolimus may avoid unnecessary invasive diagnostic procedures. Nevertheless, exclusion of other common causes of fever is essential.
Resumo:
clinical presentation is self limited. It is classified into five groups (genogroups I through V). There are numerous reports of neurologic complications, namely afebrile seizures, but only two reports of associated encephalopathy. Case Report: A 12 month old girl with previous history of a pneumonia treated with amoxicillin-clavulanic acid and clarythromycin, presented in our emergency department with strabismus, ataxia for 3 days, later associated with vomiting and diarrhea. On admission she had ataxia and an episode of strabismus, but her later neurologic exam was normal. Laboratory data revealed: 10,9 g/dL hemoglobin, 11.200/μL leukocytes, 29,1% neutrophils and 65,2% lymphocytes, 488.000/μL platelets and negative CRP. The brain MRI showed middle ear, maxillary sinus and ethmoidal opacification, with no other abnormalities. During the first day of admission she had a tonic (?) seizure for 20 minutes. CSF analysis showed 5,6 cells/μL, 100% lymphocytes, 80 mg/dL glucose and 154,1 mg/dL protein. The EEG revealed short duration paroxystic activity located to the vertex. She was treated with acyclovir, ciprofloxacin, cefthriaxone and phenytoin. Her symptoms resolved by the third day of admission. Blood samples were tested for numerous pathogens, including serology for Borrelia, which was positive for IgG but negative for IgM. Fecal sample analysis revealed positive PCR for norovirus, although it was negative in CSF samples. IL-6 was measured in the CSF and was negative (5,8 pg/mL). She had a history of recurrent otitis media and pernieal candidiasis, which led to a detailed immune function study, which showed Immunology tests revealed diminished IgA (< 0,244 g/L) and absent antibody response to vaccinations. Since she was only 13 months old when she was tested, only follow up will determine the relevance of these values. Follow up at two years of age showed no delays and a normal development. Conclusion: Norovirus encephalitis is a rare entity, although gastrointestinal infection with this agent is relatively common. Here we present a case of a probable norovirus associated encephalopathy, although PCR for norovirus was negative in CSF samples and there was no CSF cytokine increase. It was not associated with adverse neurologic outcome and so far her development is normal, unlike the evolution described in previous case reports.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
We report a primary response to Toxoplasma gondii following a hematopoietic stem cell transplantation in a patient with multiple myeloma. The primary response to T. gondii was supported by IgM, IgG and IgA seroconversion. The patient was promptly treated and there were no complications related to toxoplasmosis in the subsequent months.
Resumo:
Introdução: A narcolepsia é uma doença do sono REM com desregulação do ciclo de sono-vigília, consequente sonolência diurna e eventual associação a alucinações hipnagógicas, paralisia do sono e cataplexia. A sua prevalência é de 0,05 a 0,02% no adulto mas desconhecida na idade pediátrica. Caso clínico: Criança de seis anos, previamente saudável com sonolência excessiva até 18 horas/dia e discinésia oromandibular, desequilíbrio na marcha e movimentos coreiformes dos membros superiores. Duas semanas antes realizara vacinação para a gripe pandémica. Registou-se ainda hiperfagia diurna e nocturna durante cinco dias com resolução espontânea, episódios de cataplexia perante riso e alterações emocionais e tremor da cabeça e dos membros superiores com melhoria clínica progressiva após oito dias. Realizou RMN-CE e EEG sem alterações. O exame líquido céfalo-raquidiano e PCR para painel de vírus herpes, Mycoplasma pneumoniae e enterovírus negativas. Nesta fase realizou polissonografia com teste de latências múltiplas do sono (TLMS) sem alterações. Exame cultural do exsudado faríngeo, TASO e anticorpo AntiDnase B negativos. Da exaustiva investigação que realizou apresentava serologias ELISA e WB compatíveis com infecção por Borrelia burdorferi, pelo que cumpriu ceftriaxone 14 dias. Serologias para influenza A mostraram IgM 39 UA/mL com IgG 194 UA/mL com segunda amostra com IgM 43 UA/mL e IgG 162 UA/mL (VR IgM<20;IgG<20). O estudo da autoimunidade revelou ANA 1/320, anticorpos anticardiolipina e antinucleares extraíveis negativos. Restantes autoanticorpos e doseamento de complemento normal. Anticorpos Anti-NMDA e VKCG negativos. Doseamento de hipocretina muito diminuído com HLA DR2 e DQB1*0602 presentes. A polissonografia com TLMS, sete meses após a primeira, confirmou sonolência excessiva com quatro inícios do sono REM sugestivos de narcolepsia. Faz terapêutica com metilfenidato, a sonolência diurna diminuiu e cumpre o seu horário escolar sem limitações. Comentários: O diagnóstico de narcolepsia foi sugerido pela clínica e confirmado pelo teste de latências múltiplas. O valor de hipocretina diminuído pode sugerir uma etiologia autoimune. Uma infecção como a borreliose ou a vacinação prévia para H1N1, responsabilizada por outros casos de narcolepsia podem ter sido desencadeantes de uma alteração imunitária responsável pela doença, nesta criança com a susceptibilidade HLA DR2 e DBQ1*0602.