935 resultados para “Lateral bone augmentation” AND “dental implants”
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
No abstract
Resumo:
Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.
Resumo:
A series of propylsulfonic (MCM-SOH) and octyl co-functionalised propylsulfonic (MCM-Oc-SOH) catalysts have been prepared by post modification of MCM-41 with mercaptopropyltrimethoxysilane (MPTS) to achieve SOH surface coverages spanning the range 0.12-1 monolayer. Within the MCM-Oc-SOH series, samples with submonolayer MPTS coverages were further grafted with octyltrimethoxysilane to cap bare hydroxyl sites and tune the hydrophobicity of the support. For the MCM-SO H series NH calorimetry revealed acid strength increases as a function of sulfonic acid loading, with -ΔH(NH ) increasing from 87 to 118 kJ mol. In contrast, MCM-Oc-SOH exhibits a dramatic enhancement of acid strength for submonolayer SOH coverages, with -ΔH(NH ) found to increase to 103 kJ mol. In line with these acid strength measurements the per-site activity of the MCM-SOH series in the esterification of butanol with acetic acid was found to increase with SOH content. Incorporation of octyl groups further promotes esterification activity of all the samples within the MCM-Oc-SOH series, such that the turn over frequency of the sample with the lowest loading of SOH more than doubles. Molecular dynamic simulations indicate that the interaction of isolated sulfonic acid groups with the pore walls is the primary cause of the decrease in acid strength and activity of submonolayer samples within the MCM-SOH series. Incorporation of octyl groups results in a combination of increased hydrophobicity and lateral interactions between adjacent sulfonic acid head groups, resulting in a striking enhancement of acid strength and esterification activity. © 2010 The Royal Society of Chemistry.
Resumo:
In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.
Resumo:
Leptin is a multifunctional hormone, produced predominantly in adipocytes. It regulates energy balance through its impact on appetite and fat metabolism, and its concentration indicates the size of body fat reserves. Leptin also plays a vital role in stretch-induced surfactant production during alveolar development in the fetus. The structure, expression pattern, and role of leptin have not previously been explored in marine mammals. Phocid seals undergo cyclical changes in body composition as a result of prolonged fasting and intensive foraging bouts and experience rapid, dramatic, and repeated changes in lung volume during diving. Here, we report the tissue-specific expression pattern of leptin in these animals. This is the first demonstration of leptin expression in the lung tissue of a mature mammal, in addition to its expression in the blubber and bone marrow, in common with other animals. We propose a role for leptin in seal pulmonary surfactant production, in addition to its likely role in long-term energy balance. We identify substitutions in the phocine leptin sequence in regions normally highly conserved between widely distinct vertebrate groups, and, using a purified seal leptin antiserum, we confirm the presence of the leptin protein in gray seal lung and serum fractions. Finally, we report the substantial inadequacies of using heterologous antibodies to measure leptin in unextracted gray seal serum.
Resumo:
Introdução: Uma adequada planificação é condição sine qua non para o êxito do tratamento com implantes. No entanto, nem sempre a colocação dos implantes na posição tridimensional ideal é, logo à partida, viável. Neste contexto, a correção dos colapsos da crista óssea com tecidos duros assume especial importância. Objetivos: O objetivo desta revisão narrativa é avaliar a eficácia dos diversos procedimentos existentes para aumento do rebordo com tecidos duros, de forma a facilitar a escolha do tratamento ideal. Materiais e Métodos: Pesquisou-se nas bases de dados MEDLINE, B-on e Google Académico. As palavras-chave utilizadas foram: “guided bone regeneration”, “ridge augmentation”, “seibert classification”, “alveolar bone splitting”, “horizontal bone augmentation” e “vertical bone augmentation”. Deu-se especial ênfase a revisões sistemáticas e meta-análises. A pesquisa foi limitada a artigos publicados em inglês, espanhol e em português até abril de 2016. Foram ainda consultados os livros “Tratado de Periodontia Clínica e Implantologia Oral” de Lindhe et al. (2005), “Implantes Dentais Contemporâneos” de Misch et al. (2009) e “Reabilitação com implantes endo-ósseos” de Alcoforado et al. (2008). Resultados: De um modo geral, todos os procedimentos analisados obtiveram altas taxas de sobrevivência aquando da reabilitação com implantes. No entanto, não houve diferenças significativas entre as diversas técnicas que possam levar a uma conclusão relevante sobre qual a melhor técnica a utilizar para este tipo de procedimento. Conclusão: Há evidências insuficientes para sugerir qual a técnica que deve ser preferida para o aumento de rebordo com tecidos duros, pelo que mais estudos são necessários.
Resumo:
International audience