936 resultados para ultrasonic welding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A successful and useful treatment for end-stage heart failure is Left ventricular assist device (LVAD). An important part - a hydrodynamically suspended impeller exposed to corrosive conditions, required to sealed hermetically into micro packages. Laser beam welded (LBW) Ti6Al4V alloy has been adopted in anti-corrosion micro packages for the impeller of a (LVAD). Thin and narrow welds were required for such medical equipment. Pulsed Nd:YAG welding was successfully adopted as sealing method for the impeller. ©2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this contribution, we experimentally test the effects of azimuth and tilt angle on the acoustic reflectivity of a liquid- anisotropic solid interface. For this study, we are using a large source transducer, and acquired data for samples with different tilt angles. We use Phenolic CE material, which is known to have orthorhombic symmetry. Our results show that changes of the tilt angle produce important variations on the reflectivity that are larger as the tilt increases. The most remarkable feature is the change of the critical angle with the azimuth, which shows a larger spread for larger tilts. The spectral components of the acquired waveforms also show characteristic features linked to the location of the critical angle, we particularly observed a drop in the peak frequency. These observations suggest that care must be taken about the interpretation and inversion of observed incidence and azimuth dependent seismic reflectivities and critical angles in obtaining information on a formation's anisotropy. Zip archive contains four segy files: - LAB_TI00, is not tilted sample in contact with water, - LAB_TI30, is 30degrees tilted sample in contact with water, - LAB_TI45, is 45 degrees tilted sample in contact with water, - LAB_TI90, is 90 degrees tilted sample in contact with water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgements The authors would like to gratefully acknowledge and appreciate the School of Engineering, University of Aberdeen, Aberdeen, Scotland, UK, for the provision of the laboratory facilities necessary for completing this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgements The authors would like to gratefully acknowledge and appreciate the School of Engineering, University of Aberdeen, Aberdeen, Scotland, UK, for the provision of the laboratory facilities necessary for completing this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultrasonic non-destructive testing of components may encounter considerable difficulties to interpret some inspections results mainly in anisotropic crystalline structures. A numerical method for the simulation of elastic wave propagation in homogeneous elastically anisotropic media, based on the general finite element approach, is used to help this interpretation. The successful modeling of elastic field associated with NDE is based on the generation of a realistic pulsed ultrasonic wave, which is launched from a piezoelectric transducer into the material under inspection. The values of elastic constants are great interest information that provide the application of equations analytical models, until small and medium complexity problems through programs of numerical analysis as finite elements and/or boundary elements. The aim of this work is the comparison between the results of numerical solution of an ultrasonic wave, which is obtained from transient excitation pulse that can be specified by either force or displacement variation across the aperture of the transducer, and the results obtained from a experiment that was realized in an aluminum block in the IEN Ultrasonic Laboratory. The wave propagation can be simulated using all the characteristics of the material used in the experiment evaluation associated to boundary conditions and from these results, the comparison can be made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ceramic materials have been widely used for various purposes in many different industries due to certain characteristics, such as high melting point and high resistance to corrosion. Concerning the areas of applications, automobile, aeronautics, naval and even nuclear, the characteristics of these materials should be strictly controlled. In the nuclear area, ceramics are of great importance once they are the nuclear fuel pellets and must have, among other features, a well controlled porosity due to mechanical strength and thermal conductivity required by the application. Generally, the techniques used to characterize nuclear fuel are destructive and require costly equipment and facilities. This paper aims to present a nondestructive technique for ceramic characterization using ultrasound. This technique differs from other ultrasonic techniques because it uses ultrasonic pulse in frequency domain instead of time domain, associating the characteristics of the analyzed material with its frequency spectrum. In the present work, 40 Alumina (Al2O3) ceramic pellets with porosities ranging from 5% to 37%, in absolute terms measured by Archimedes technique, were tested. It can be observed that the frequency spectrum of each pellet varies according to its respective porosity and microstructure, allowing a fast and non-destructive association of the same characteristics with the same spectra pellets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ultrasound Laboratory of the Nuclear Engineering Institute (LABUS / IEN) has developed an ultrasonic technique to measure porosity in nuclear fuel pellets (UO2). By difficulties related to the handling of UO2 pellets, Alumina (Al2O3) pellets have been used in preliminary tests, until a methodology for tests with pellets of UO2 could be defined. In a previous work, in which a contact ultrasonic technique was used, good results were obtained to measure the porosity of Alumina pellets. In the current studies, it was found that the frequency spectrum of an ultrasonic pulse is very sensitive to the porosity of the medium in which it propagates. In order to define the most appropriate experimental apparatus for using immersion technique in future tests, two ultrasonic systems, available in LABUS, which permit to work with the ultrasonic pulse in the frequency domain were evaluated . One system was the Explorer II (Matec INSTRUMENTS) and the other the ultrasonic pulse generator Epoch 4 Plus (Panametrics) coupled with an oscilloscope TDS 3032B (Tektronix). For this evaluation, several frequency spectra were obtained with the two equipment, by the passage of the ultrasonic wave in the same pellet of Alumina. This procedure was performed on four different days, on each day 12 ultrasonic signals were acquired, one signal every 10 minutes, with each apparatus. The results were compared and analyzed as regard the repeatability of the frequency spectra obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of polymeric membranes is extremely important in several industries such as nuclear, biotechnology, chemical and pharmaceutical. In the nuclear area, for instance, systems based on membrane separation technologies are currently being used in the treatment of radioactive liquid effluent, and new technologies using membranes are being developed at a great rate. The knowledge of the physical characteristics of these membranes, such as, pore size and the pore size distribution, is very important to the membranes separation processes. Only after these characteristics are known is it possible to determine the type and to choose a particular membrane for a specific application. In this work, two ultrasonic non destructive techniques were used to determine the porosity of membranes: pulse echo and transmission. A 25 MHz immersion transducer was used. Ultrasonic signals were acquired, for both techniques, after the ultrasonic waves passed through a microfiltration polymeric membrane of pore size of 0.45 μm and thickness of 180 μm. After the emitted ultrasonic signal crossed the membrane, the received signal brought several information on the influence of the membrane porosity in the standard signal of the ultrasonic wave. The ultrasonic signals were acquired in the time domain and changed to the frequency domain by application of the Fourier Fast Transform (FFT), thus generating the material frequency spectrum. For the pulse echo technique, the ultrasonic spectrum frequency changed after the ultrasonic wave crossed the membrane. With the transmission technique there was only a displacement of the ultrasonic signal at the time domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the refractory period that follows ejaculation, the male rat regularly emits 22-kilohertz vocalizations. These cease after about three-fourths of the total period has elapsed, and this corresponds to an "absolute refractory period" during which the male cannot spontaneously initiate copulation. Similar 22-kilohertz vocalizations occur in other social contexts, and in general they appear to be desist-contact signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In shipbuilding industry welding of primer coated and tack welded steel products cause different issues. Primer coated steel products are commonly used at shipyards to ensure corrosion free storage of products in outdoor conditions. However usage of primer can cause imperfections to welds. To prevent porosity primed steel products are usually welded with tubular welding wires. Tack welds cause commonly interferences in mechanized welding when over welded, which increases costs related to welding due to increased need of preparing and repairing. The aim of this study is to research possibilities of advanced solid wire MAG-welding processes to deal with these two previously mentioned problems. This study concentrates to examine possibilities of MAG-welding, pulse MAG-welding, double pulse MAG-welding, RapidArc and ForceArc processes. Large amount of experiments were made to find out the produced porosity and the ability to over weld tack welds with each process in different circumstances. In welding of primed steel products porosity is caused mainly by hydrogen, CO, CO2, nitrous gases and zinc fumes. It was found in experiments that porosity of MAG-welding can be greatly decreased by using pulse MAG-welding instead. Also reduction of welding speed, usage of air gap and usage of solid wire product with higher amount of alloying elements reduces porosity. Researched advanced MAG-welding processes did not have an improvement into over welding of tack welds. With studied throat thicknesses and welding positions conventional MAG-welding managed better over welding of tack welds than the four studied advanced MAG-welding processes. Studied solid wire MAG-welding processes would be best suited at shipyard for mechanized welding in welding position PB. In welding positions PD and PG tubular welding wires are clearly more productive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is made in cooperation with Wärtsilä and Sandvik. The main purpose of the thesis is to clarify the best suitable American standards for European standards used in Wärtsilä’s investigation checklist and to make wide and easily readable tables for Wärtsilä and their subcontractors. One of the most important issues is to make clear if the compared American standards are demanding enough for Wärtsilä’s needs. The research is done by comparing EN standards mentioned in Wärtsilä’s investigation checklist to corresponding ASME, AWS, ASNT and ASTM standards. The research shows that there is visible lack of requirements in American standards compared to European ones. Some areas of American standards are more demanding than European standards but in larger scale EN standards are much wider and more demanding than American standards. Because of these reasons, usage of European standards should be recommended for Wärtsilä’s subcontractors to ensure the quality and reliability of production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän kandidaatintyön tarkoituksena on selvittää hitsien tarkastukseen käytettyjen NDT-menetelmien nykytilannetta. Työssä kerrotaan mitä reaaliaikainen NDT-tarkastus on ja mitä menetelmiä siihen voidaan käyttää. Työn tarkoituksena on antaa lukijalle kokonaiskuva NDT-tarkastuksen nykytilasta ja siinä käytettävistä menetelmistä. Tutkimus suoritettiin kirjallisuuskatsauksena. Kirjallisuuskatsaus on luonteeltaan toteava. Lähteiden etsintä suoritettiin suurimmalta osin Internet-hakuna. NDT-tarkastusmenetelmät voidaan jakaa kahteen pääkategoriaan; pinta- ja volumetrisiin menetelmiin. Kaikki tarkastusmenetelmät eivät sovellu reaaliaikaiseen tarkastukseen. Hitsien tarkastuksessa käytetyimmät reaaliaikaiset menetelmät ovat: ultraäänitarkastus, radiografinen tarkastus, optinen spektroskopia, termografia ja pyörrevirtatarkastus. Kaikilla reaaliaikaisilla menetelmillä on omat vahvuutensa ja heikkoutensa. Työssä esitetään myös CASE-esimerkkejä reaaliaikaisesta hitsien tarkastamisesta.Tärkeimpinä johtopäätöksinä voidaan nähdä se, että hitsien NDT-tarkastuksen onnistuminen on aina hyvin tapauskohtaista ja riippuu useista muuttujista. Tästä syystä tällä hetkellä NDT-tarkastusmenetelmistä ei voi valita parasta kaikkiin käyttökohteisiin sopivaa menetelmää. Monessa prosessissa NDT-tarkastustehokkuutta ei määritä mekaanisen laitteiston mittaustarkkuus, vaan tulosten analysointiin käytettyjen algoritmien tehottomuus. Tutkimuksessa esitetään myös idea hybridi-NDT-tarkastusjärjestelmästä, jolla saataisiin havaittua tehokkaasti sekä pinta-että volumetrisia virheitä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to extend the use of combined longitudinal (P-wave) and shear (S-wave) ultrasonic wave reflection (UWR) to monitor the setting and stiffening of self-compacting pastes and concretes. An additional objective was to interpret the UWR responses of various modified cement pastes. A polymeric buffer with acoustic impedance close to that of cement paste, high impact polystyrene, was chosen to obtain sensitive results from the early hydration period. Criteria for initial and final set developed by our group in a prior study were used to compute setting times by UWR. UWR results were compared with standard penetration measurements. Stiffening behavior and setting times for normal cement pastes, pastes modified with mineral and chemical admixtures, self-compacting pastes, and concretes were explored using penetration resistance, S-wave and P-wave reflection. All three methods showed that set times of pastes varied linearly with w/c, that superplasticizer and fly ash delayed the set times of pastes, and that differences in w/cm, sp/cm, and fa/cm could be detected. Final set times determined from UWR correlated well with those from penetration resistance. Initial set times from S-wave reflection did not correlate very well with those from penetration resistance. Final set times from P-wave and S-wave reflection were roughly the same. Pastes with different chemical admixtures were tested, and the effects of these admixtures on stiffening were determined using UWR. Self-compacting concretes were studied using UWR, and their response and setting times were largely similar to that of corresponding self-compacting pastes. The P-wave reflection response was explored in detail, and the phenomenon of partial debonding and the factors affecting it were explained. Partial debonding is probably caused by autogenous shrinkage at final set, and was controlled and limited by water. The extent of partial debonding was higher with the transducers placed on the side as opposed to the bottom, and the S-wave transducer seemed to promote debonding in the P-wave reflection, whereas the P-wave transducer seemed to reduce debonding in the S-wave reflection. Simultaneous formwork pressure testing and UWR were performed; however, no clear correlation was seen between the two properties.