938 resultados para template matching
Resumo:
Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.
Bone response to loaded implants with non-matching implant-abutment diameters in the canine mandible
Resumo:
BACKGROUND: One way to evaluate various implant restorations is to measure the amount of bone change that occurs at the crestal bone. The objective of this study was to histologically evaluate the alveolar bone change around a bone-level, non-matching implant-abutment diameter configuration that incorporated a horizontal offset and a Morse taper internal connection. METHODS: The study design included extraction of all mandibular premolars and first molars in five canines. After 3 months, 12 dental implants were placed at three levels in each dog: even with the alveolar crest, 1 mm above the alveolar crest, and 1 mm below the alveolar crest. The implants were submerged on one side of the mandible. On the other side, healing abutments were exposed to the oral cavity (non-submerged). Gold crowns were attached 2 months after implant placement. The dogs were sacrificed 6 months postloading, and specimens were processed for histologic and histometric analyses. RESULTS: Evaluation of the specimens indicated that the marginal bone remained near the top of the implants under submerged and non-submerged conditions. The amount of bone change for submerged implants placed even with, 1 mm below, and 1 mm above the alveolar crest was -0.34, -1.29, and 0.04 mm, respectively (negative values indicate bone loss). For non-submerged implants, the respective values were -0.38, -1.13, and 0.19 mm. For submerged and non-submerged implants, there were significant differences in the amount of bone change among the three groups (P <0.05). The percentage of bone-to-implant contact for submerged implants was 73.3%, 71.8%, and 71.5%. For non-submerged implants, the respective numbers were 73.2%, 74.5%, and 76%. No significant differences occurred with regard to the percentage of bone contact. CONCLUSIONS: Minimal histologic bone loss occurred when dental implants with non-matching implant-abutment diameters were placed at the bone crest and were loaded for 6 months in the canine. The bone loss was significantly less (five- to six-fold) than that reported for bone-level implants with matching implant-abutment diameters (butt-joint connections).
Resumo:
We describe the use of log file analysis to investigate whether the use of CSCL applications corresponds to its didactical purposes. Exemplarily we examine the use of the web-based system CommSy as software support for project-oriented university courses. We present two findings: (1) We suggest measures to shape the context of CSCL applications and support their initial and continuous use. (2) We show how log files can be used to analyze how, when and by whom a CSCL system is used and thus help to validate further empirical findings. However, log file analyses can only be interpreted reasonably when additional data concerning the context of use is available.
Resumo:
This paper presents an empirical study of affine invariant feature detectors to perform matching on video sequences of people with non-rigid surface deformation. Recent advances in feature detection and wide baseline matching have focused on static scenes. Video frames of human movement capture highly non-rigid deformation such as loose hair, cloth creases, skin stretching and free flowing clothing. This study evaluates the performance of six widely used feature detectors for sparse temporal correspondence on single view and multiple view video sequences. Quantitative evaluation is performed of both the number of features detected and their temporal matching against and without ground truth correspondence. Recall-accuracy analysis of feature matching is reported for temporal correspondence on single view and multiple view sequences of people with variation in clothing and movement. This analysis identifies that existing feature detection and matching algorithms are unreliable for fast movement with common clothing.
Resumo:
Successful computer-supported distance education requires that its enabling technologies are accessible and usable anywhere. They should work seamlessly inside and outside the information superhighway, wherever the target learners are located, without obtruding on the learning activity. It has long been recognised that the usability of interactive computer systems is inversely related to the visibility of the implementing technologies. Reducing the visibility of technology is especially challenging in the area of online language learning systems, which require high levels of interactivity and communication along multiple dimensions such as speaking, listening, reading and writing. In this article, the authors review the concept of invisibility as it applies to the design of interactive technologies and appliances. They describe a specialised appliance matched to the requirements for distance second language learning, and report on a successful multi-phase evaluation process, including initial field testing at a Thai open university.
Resumo:
Successful computer-supported distance education requires that its enabling technologies are accessible and usable anywhere. They should work seamlessly inside and outside the information superhighway, wherever the target learners are located, without obtruding on the learning activity. It has long been recognised that the usability of interactive computer systems is inversely related to the visibility of the implementing technologies. Reducing the visibility of technology is especially challenging in the area of online language learning systems, which require high levels of interactivity and communication along multiple dimensions such as speaking, listening, reading and writing. In this article, the authors review the concept of invisibility as it applies to the design of interactive technologies and appliances. They describe a specialised appliance matched to the requirements for distance second language learning, and report on a successful multi-phase evaluation process, including initial field testing at a Thai open university.
Resumo:
When stereo images are captured under less than ideal conditions, there may be inconsistencies between the two images in brightness, contrast, blurring, etc. When stereo matching is performed between the images, these variations can greatly reduce the quality of the resulting depth map. In this paper we propose a method for correcting sharpness variations in stereo image pairs which is performed as a pre-processing step to stereo matching. Our method is based on scaling the 2D discrete cosine transform (DCT) coefficients of both images so that the two images have the same amount of energy in each of a set of frequency bands. Experiments show that applying the proposed correction method can greatly improve the disparity map quality when one image in a stereo pair is more blurred than the other.
Resumo:
Self-Determination Theory (Deci and Ryan in Intrinsic motivation and self-determination in human behavior. Plenum Press, New York, 1985) suggests that certain experiences, such as competence, are equally beneficial to everyone’s well-being (universal hypothesis), whereas Motive Disposition Theory (McClelland in Human motivation. Scott, Foresman, Glenview, IL, 1985) predicts that some people, such as those with a high achievement motive, should benefit particularly from such experiences (matching hypothesis). Existing research on motives as moderators of the relationship between basic need satisfaction and positive outcomes supports both these seemingly inconsistent views. Focusing on the achievement motive, we sought to resolve this inconsistency by considering the specificity of the outcome variables. When predicting domain-specific well-being and flow, the achievement motive should interact with felt competence. However, when it comes to predicting general well-being and flow, felt competence should unfold its effects without being moderated by the achievement motive. Two studies confirmed these assumptions indicating that the universal and matching hypotheses are complementary rather than mutually exclusive.
Resumo:
Storing and recalling spiking sequences is a general problem the brain needs to solve. It is, however, unclear what type of biologically plausible learning rule is suited to learn a wide class of spatiotemporal activity patterns in a robust way. Here we consider a recurrent network of stochastic spiking neurons composed of both visible and hidden neurons. We derive a generic learning rule that is matched to the neural dynamics by minimizing an upper bound on the Kullback–Leibler divergence from the target distribution to the model distribution. The derived learning rule is consistent with spike-timing dependent plasticity in that a presynaptic spike preceding a postsynaptic spike elicits potentiation while otherwise depression emerges. Furthermore, the learning rule for synapses that target visible neurons can be matched to the recently proposed voltage-triplet rule. The learning rule for synapses that target hidden neurons is modulated by a global factor, which shares properties with astrocytes and gives rise to testable predictions.
Resumo:
Dicalcium phosphate dihydrate (brushite) and octacalcium phosphate (OCP) crystals are precursors of hydroxyapatite (HAp) for tooth enamel, dentine, and bones formation in living organisms. Here, we introduce a new method for biomimicking brushite and OCP in starch using single and double diffusion techniques. Brushite and OCP crystals were grown by precipitation in starch after gelation. The obtained materials were analyzed by infrared spectroscopy (IR), scanning electron microscopy (SEM), X-ray diffraction (XRD), and confocal laser scanning microscopy (CLSM). IR spectra demonstrate starch inclusion by peak shifts in the 2900–3500 cm–1 region. SEM showed two different morphologies: plate-shaped and needle-like crystals. Calcium phosphate/starch aggregates bear strong resemblance to prismatic brushite kidney stones. This may open up a clue to understand the mechanism of kidney stone formation.