973 resultados para spray arc
Resumo:
The Capacitated Arc Routing Problem (CARP) is a well-known NP-hard combinatorial optimization problem where, given an undirected graph, the objective is to find a minimum cost set of tours servicing a subset of required edges under vehicle capacity constraints. There are numerous applications for the CARP, such as street sweeping, garbage collection, mail delivery, school bus routing, and meter reading. A Greedy Randomized Adaptive Search Procedure (GRASP) with Path-Relinking (PR) is proposed and compared with other successful CARP metaheuristics. Some features of this GRASP with PR are (i) reactive parameter tuning, where the parameter value is stochastically selected biased in favor of those values which historically produced the best solutions in average; (ii) a statistical filter, which discard initial solutions if they are unlikely to improve the incumbent best solution; (iii) infeasible local search, where high-quality solutions, though infeasible, are used to explore the feasible/infeasible boundaries of the solution space; (iv) evolutionary PR, a recent trend where the pool of elite solutions is progressively improved by successive relinking of pairs of elite solutions. Computational tests were conducted using a set of 81 instances, and results reveal that the GRASP is very competitive, achieving the best overall deviation from lower bounds and the highest number of best solutions found. © 2011 Elsevier Ltd. All rights reserved.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.
Resumo:
The study aimed to evaluate the performance of air assistance in spray booms using different types of nozzles and spray volumes. We took into account spray deposits, fall armyworm control and crop corn performance in a narrow row cropping system. The experiment was carried out at the experimental area of Sao Paulo State University, Botucatu/SP, Brazil, during the 2008/2009 agricultural season, in randomized blocks with a factorial scheme (2×2+1) and four replications. Two spray nozzles (flat fan nozzle and hollow cone nozzle) were tested, combined with two air assistance levels in the spray boom (with and without air assistance) and a treatment control. In the experimental spraying, Spinosad insecticide was sprayed in amounts of 48 g active substance (a.s.)/ha. The air assistance in the spray boom increased the spray deposits in the V 4 growth stage of the corn plants. Moreover, the application of this technology showed higher efficiency on fall armyworm control, reaching a 100% level 15 days after spraying, in the V 10 growth stage of the plants. The hollow cone nozzle increased the spray deposit level on the corn plants compared with the flat fan nozzle, at growth stage V 4. However, the flat fan nozzle, combined with air assistance technology, was more effective for controlling fall armyworm in the same growth stage (V 4), although the hollow cone nozzle increased the deposit levels on the plants. All the technologies tested in the study promoted a reduction of plant damage from fall armyworm attack. Corn productivity is directly related to the control efficiency of fall armyworm.
Resumo:
The high demand of pesticides in the production systems makes the application technology one of the main alternatives to optimize the products efficiency. In this context, the study aimed to evaluate the effects of spray nozzles and spray volumes on spraying deposits, armyworm control and crop corn performance in narrow row sowing system. The experiment was carried out at experimental area of Sao Paulo State University, Campus of Botucatu/SP, Brazil, during the 2009/2010 agricultural season, in randomized blocks with factorial scheme (2x2+1) and four replications. It was tested two flat fan spray nozzles (with and without air induction) combined with two spray volumes (100 and 200 L ha-1) plus a control treatment. There was no influence of spray nozzles (without air induction) in the spray deposits levels on plants. However, the flat fan nozzle with air induction was more effective on fall armyworm, with 100% of control against 47.84% from other at 15 days after spraying. The increase in the spray volume promoted high spray deposits (415.4 and 388.6 μL g-1 dry mass for flat fan nozzle with and without air induction, respectively at V10 growth stage) and consequently, the highest spray volume (200 L-1) was more efficient in the fall armyworm suppression, with 100% of control. All the technologies tested showed lower plant injury from fall armyworm. The insecticide sprayed with different technologies did not affect the parameters of plant height and leaf area index. The corn productivity was directly related with control efficiency of fall armyworm. © 2012 Academic Journals Inc.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.
Resumo:
The objective of this study was to evaluate different strategies for the application of entomopathogenic nematodes (EPN). Three different models of spray nozzles with air induction (AI 11003, TTI 11003 and AD-IA 11004), three spray pressures (207, 413 and 720 kPa), four different additives for tank mixtures (cane molasses, mineral oil, vegetable oil and glycerin) and the influence of tank mixture stirring time were all evaluated for their effect on EPN (Steinernema feltiae) viability and pathogenicity. The different nozzles, at pressures of up to 620 kPa, were found to be compatible with S. feltiae. Vegetable oil, mineral oil and molasses were found to be compatible adjuvants for S. feltiae, and stirring in a motorized backpack sprayer for 30 minutes did not impact the viability or pathogenicity of this nematode. Appropriate techniques for the application of nematodes with backpack sprayers are discussed. © 2013 Moreira et al.
Resumo:
Microbial enzymes have been used for various biotechnological applications; however, enzyme stabilization remains a challenge for industries and needs to be considered. This study describes the effects of spray-drying conditions on the activity and stability of β-fructofuranosidase from Fusarium graminearum. The extracellular enzyme β-fructofuranosidase was spray dried in the presence of stabilizers, including starch (Capsul) (SC), microcrystalline cellulose (MC), trehalose (TR), lactose (LC) and β-cyclodextrin (CD). In the presence of TR (2% w/v), the enzymatic activity was fully retained. After 1 year of storage, 74% of the enzymatic activity was maintained with the CD stabilizer (10% w/v). The residual activity was maintained as high as 80% for 1 h at 70°C when MC, SC and CD (5% w/v) stabilizers were used. Spray drying with carbohydrates was effective in stabilizing the F. graminearum β-fructofuranosidase, improved enzymatic properties compared to the soluble enzyme and demonstrated a potential use in future biotechnology applications. © 2013 Informa UK Ltd. All rights reserved.
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Biotecnologia - IQ