840 resultados para operational reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three terminal ‘dotted-I’ interconnect structures, with vias at both ends and an additional via in the middle, were tested under various test conditions. Mortalities (failures) were found in right segments with jL value as low as 1250 A/cm, and the mortality of a dotted-I segment is dependent on the direction and magnitude of the current in the adjacent segment. Some mortalities were also found in the right segments under a test condition where no failure was expected. Cu extrusion along the delaminated Cu/Si₃N₄ interface near the central via region was believed to cause the unexpected failures. From the time-to-failure (TTF), it is possible to quantify the Cu/Si₃N₄ interfacial strength and bonding energy. Hence, the demonstrated test methodology can be used to investigate the integrity of the Cu dual damascene processes. As conventionally determined critical jL values in two-terminal via-terminated lines cannot be directly applied to interconnects with branched segments, this also serves as a good methodology to identify the critical effective jL values for immortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavelength division multiplexing (WDM) networks have been adopted as a near-future solution for the broadband Internet. In previous work we proposed a new architecture, named enhanced grooming (G+), that extends the capabilities of traditional optical routes (lightpaths). In this paper, we compare the operational expenditures incurred by routing a set of demands using lightpaths with that of lighttours. The comparison is done by solving an integer linear programming (ILP) problem based on a path formulation. Results show that, under the assumption of single-hop routing, almost 15% of the operational cost can be reduced with our architecture. In multi-hop routing the operation cost is reduced in 7.1% and at the same time the ratio of operational cost to number of optical-electro-optical conversions is reduced for our architecture. This means that ISPs could provide the same satisfaction in terms of delay to the end-user with a lower investment in the network architecture

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exam questions, exercises and solutions for a second year operational research course.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Challenges for Web Science - applications in Bio & OR

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validity and reliability pie animation for display in RM&EBP

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the reliability of Neupsilin Brief Neuropsychological Assessment Instrument, a brief battery developed in Brazil. Hundred two Brazilian man and women participated, from 18 to 40 years of age. It was evaluated the test-retest reliability of the Neupsilin tasks and the reliability of the correction of the constructional praxis task by different evaluators. The data were analyzed by Spearman’s correlation, intraclass correlation and Cronbach’s alpha. Language, memory, praxis and executive functions presented the highest correlations in the test-retest analyses. The agreement in the correction of the constructional praxis task was moderate to high. The results indicate temporal reliability of Neupsilin tasks and inter-rater agreement in the correction of the constructional praxis task. Suggestions to improve the tasks, the validity and reliability of Neupsilin were presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the construct validity and reliability of Femininity and Masculinity Inventory-Imafe (Lara, 1993), and calculated standardized punctuations for Colombian teenagers and young adults. Participants were 1527 male and female, between 15 and 42. The general and scale reliability was evaluated through Alfa and Guttmann coefficients, and the factor analysis was used to estimate the construct validity. Standardized punctuations were obtained for gender, since there were statistically significant differences for sex in the six scales of the instrument. The inventory presented reliability values that oscillated between .76 and .88, and the factorial analysis showed three factors coherent with the factors found in its original validation. Correlacional inter-scales analysis and sex-differences were theoretically consistent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the ‘interrater reliability’ of the Alberta Infant Motor Scale (AIMS) in term and preterm born infants between 10 to 16 months age from Talca province, Maule Region - Chile. Subjects: 115 infants between 10 to 16 months age were incorporated to the study; 95 term born infants were attended in the local Health Centre in Talca City, and 20 preterm infants belonged to the Premature Infants Follow-Up Programme of Talca Regional Hospital. Methods: The motor behaviour of each infant was recorded and later it was assessed by two trained assessors using AIMS. It was obtained the total AIMS’ score and also from prone, supine, seated, and stand subscales. For ‘interrater reliability’ analysis it was used the Intraclass Coefficient of Correlation (ICC), the Standard Error of Measurement (SEM) and 95% limits of agreement. Results: The obtained ICC for the total scores AIMS were major than 0.94 (p<0.0002) for term and preterm born infants. The SEM of total scores was less than 3.1 points, higher than what was found in other similar studies. The 95% limits of agreement were +5.3 to -4.1 points and +7.7 to – 3.9 points in term and preterm born, respectively, revealing ‘interrater agreement’. Conclusion: The AIMS showed adequate ‘interrater reliable’ levels when was applied in Chilean term and preterm born from 10 to 16 month’s age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: La escala de severidad en emergencias es una herramienta que ofrece seguridad a pacientes en servicios de urgencias. Este trabajo evalúa la aplicación de la escala ESI 4.0 en términos de oportunidad de atención y consumo de recursos en la Fundación Santa Fé de Bogotá, para comparar los resultados con parámetros estándar. Metodología Estudio observacional analítico de corte transversal. Se incluyeron 385 pacientes aleatorizados por nivel de atención. Se tomaron datos demográficos y variables como consumo de recursos y destino del paciente para su descripción y análisis. Resultados: El promedio de edad fue 44.9 años IC95%42.9–46.9, el 54.5% fueron mujeres. Se encontró un tiempo promedio de espera para nivel 1 de 1.39 min, para el nivel 2 de 22.9 min 2, para el nivel 3 de 41.9 min, para el nivel 4 de 56.9 min y para el nivel 5 de 52.1 min. El tiempo promedio de estancia en urgencias fue 5.9 horas y el 78.9% consumió recursos. Al comparar los tiempos con estándares mundiales en el nivel 1, 2 y 3 son significativamente mayores (P<0,05), en el nivel 4 es similar (p0,51) y en el nivel 5 es significativamente menor (p=0,00) Discusión: La escala ESI 4.0 es una herramienta segura, con un comportamiento similar en oportunidad de atención y consumo de recursos con respecto a los estándares de cuidado en los servicios de urgencias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze a monopolist’s pricing and product reliability problem when consumers are entitled to product replacement but have heterogeneous cost of exercising this right, and we assess the implications of a decrease in consumers’ claiming cost on reliability, profit, and welfare. We find that reducing consumers’ claiming cost may reduce reliability and increase profit. Additionally, the model can explain why some firms encourage consumers to complain while others discourage consumers from complaining. We also show that welfare and profit are partially aligned, specially when consumers’ claiming cost are relatively low and the firm prefers to promote complaints; consequently, we find that encouraging complaints will eventually increase welfare

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo de este trabajo es hacer un estudio sobre la cadena de suministros en organizaciones empresariales desde la Dinámica de Sistemas y como esta puede aportar al desempeño y el control de las cadenas de suministros. Se buscará Abordar el cocimiento sobre tres perspectivas de Supply Chain y su relación con la dinámica de sistemas. También se buscará identificar los tipos de integración en las actividades de la gestión en la cadena de suministros y sus horizontes de planeación. Por último, se pretende analizar las aplicaciones de Supply Chain Management que se han basado en el uso de la metodología de dinámica de sistemas. Para esto, la investigación empezará por definir la problemática alrededor de unir estas dos áreas y definirá el marco teórico que fundan estas dos disciplinas. Luego se abordará la metodología usada por la Dinámica de Sistemas y los diferentes aspectos de la cadena de suministros. Se Ahondará en el acercamiento de las dos disciplinas y como convergen ayudando la SD a la SCM (Supply Chain Management). En este punto también se describirán los trabajos en los diferentes enfoques que se han hecho a partir de uso de la dinámica de sistemas. Por último, presentaremos las correspondientes conclusiones y comentarios acerca de este campo de investigación y su pertinencia en el campo de la Supply Chain. Esta investigación abarca dos grandes corrientes de pensamiento, una sistémica, a través de la metodología de dinámica de sistemas y la otra, lógico analítica la cual es usada en Supply Chain. Se realizó una revisión de la literatura sobre las aplicaciones de dinámica de sistemas (SD) en el área de Supply Chain, sus puntos en común y se documentaron importantes empleos de esta metodología que se han hecho en la gestión de la cadena de suministros.