920 resultados para lived-experience
Resumo:
A search for heavy long-lived multi-charged particles is performed using the ATLAS detector at the LHC. Data collected in 2012 at s√=8 TeV from pp collisions corresponding to an integrated luminosity of 20.3 fb−1 are examined. Particles producing anomalously high ionisation, consistent with long-lived massive particles with electric charges from |q|=2e to |q|=6e are searched for. No signal candidate events are observed, and 95% confidence level cross-section upper limits are interpreted as lower mass limits for a Drell--Yan production model. The mass limits range between 660 and 785 GeV.
Resumo:
A search for the decay of neutral, weakly interacting, long-lived particles using data collected by the ATLAS detector at the LHC is presented. This analysis uses the full dataset recorded in 2012: 20.3 fb−1 of proton--proton collision data at s√=8 TeV. The search employs techniques for reconstructing decay vertices of long-lived particles decaying to jets in the inner tracking detector and muon spectrometer. Signal events require at least two reconstructed vertices. No significant excess of events over the expected background is found, and limits as a function of proper lifetime are reported for the decay of the Higgs boson and other scalar bosons to long-lived particles and for Hidden Valley Z′ and Stealth SUSY benchmark models. The first search results for displaced decays in Z′ and Stealth SUSY models are presented. The upper bounds of the excluded proper lifetimes are the most stringent to date.
Resumo:
The ATLAS detector at the Large Hadron Collider at CERN is used to search for the decay of a scalar boson to a pair of long-lived particles, neutral under the Standard Model gauge group, in 20.3 fb−1 of data collected in proton--proton collisions at s√ = 8 TeV. This search is sensitive to long-lived particles that decay to Standard Model particles producing jets at the outer edge of the ATLAS electromagnetic calorimeter or inside the hadronic calorimeter. No significant excess of events is observed. Limits are reported on the product of the scalar boson production cross section times branching ratio into long-lived neutral particles as a function of the proper lifetime of the particles. Limits are reported for boson masses from 100 GeV to 900 GeV, and a long-lived neutral particle mass from 10 GeV to 150 GeV.
Resumo:
Searches for heavy long-lived charged particles are performed using a data sample of 19.8 fb−1 from proton--proton collisions at a centre-of-mass energy of s√ = 8 TeV collected by the ATLAS detector at the Large Hadron Collider. No excess is observed above the estimated background and limits are placed on the mass of long-lived particles in various supersymmetric models. Long-lived tau sleptons in models with gauge-mediated symmetry breaking are excluded up to masses between 440 and 385 GeV for tan(beta) between 10 and 50, with a 290 GeV limit in the case where only direct tau slepton production is considered. In the context of simplified LeptoSUSY models, where sleptons are stable and have a mass of 300 GeV, squark and gluino masses are excluded up to a mass of 1500 and 1360 GeV, respectively. Directly produced charginos, in simplified models where they are nearly degenerate to the lightest neutralino, are excluded up to a mass of 620 GeV. R-hadrons, composites containing a gluino, bottom squark or top squark, are excluded up to a mass of 1270, 845 and 900 GeV, respectively, using the full detector; and up to a mass of 1260, 835 and 870 GeV using an approach disregarding information from the muon spectrometer.
Resumo:
BACKGROUND: Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. METHODS: In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). RESULTS: The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. CONCLUSIONS: FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility.
Resumo:
Many extensions of the Standard Model posit the existence of heavy particles with long lifetimes. This article presents the results of a search for events containing at least one long-lived particle that decays at a significant distance from its production point into two leptons or into five or more charged particles. This analysis uses a data sample of proton-proton collisions at s√ = 8 TeV corresponding to an integrated luminosity of 20.3 fb−1 collected in 2012 by the ATLAS detector operating at the Large Hadron Collider. No events are observed in any of the signal regions, and limits are set on model parameters within supersymmetric scenarios involving R-parity violation, split supersymmetry, and gauge mediation. In some of the search channels, the trigger and search strategy are based only on the decay products of individual long-lived particles, irrespective of the rest of the event. In these cases, the provided limits can easily be reinterpreted in different scenarios.
Resumo:
Tese de Doutoramento em Estudos da Criança - Especialidade Comunicação Visual e Expressão Plástica
Resumo:
OBJECTIVE: To analyze the initial clinical experience of transmyocardial laser revascularization (TMLR) in patients with severe diffuse coronary artery disease. METHODS: Between February, 1998 and February, 1999, 20 patients were submitted to TMLR at the Heart Institute (InCor), University of São Paulo Medical School, Brazil, isolated or in association with conventional coronary artery bypass graft (CABG). All patients had severe diffuse coronary artery disease, with angina functional class III/IV (Canadian Cardiovascular Society score) unresponsive to medical therapy. Fourteen patients were submitted to TMLR as the sole therapy, whereas 6 underwent concomitant CABG. Fifty per cent of the patients had either been previously submitted to a CABG or to a percutaneous transluminal coronary angioplasty (PTCA). Mean age was 60 years, ranging from 45 to 74 years. RESULTS: All patients had three-vessel disease, with normal or mildly impaired left ventricular global function. Follow-up ranged from 1 to 13 months (mean 6.6 months), with no postoperative short or long term mortality. There was significant symptom improvement after the procedure, with 85% of the patients free of angina, and the remaining 15 % of the patients showing improvement in functional class, as well as in exercise tolerance. CONCLUSION: This novel technique can be considered a low risk alternative for a highly selected group of patients not suitable for conventional revascularization procedures.
Resumo:
OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.
Resumo:
Relatório de atividade profissional de mestrado em Ciências – Formação Contínua de Professores (área de especialização em Matemática)
Resumo:
OBJECTIVE: To assess by Doppler echocardiography the structural and functional alterations of rat heart with surgical induced extensive myocardial infarction. METHODS: Five weeks after surgical ligature of the left coronary artery, 38 Wistar-EPM rats of both sexes, 10 of them with extensive infarction, undergone anatomical and functional evaluation by Doppler echocardiography and then euthanized for anatomopathological analysis. RESULTS: Echocardiography was 100% sensible and specific to anatomopathological confirmed extensive miocardial infarction. Extensive infarction lead to dilatation of left ventricle (diastolic diameter: 0.89cm vs.0.64cm; systolic: 0.72cm vs. 0.33cm) and left atrium (0.55cm vs. 0.33cm); thinning of left ventricular anterior wall (systolic: 0.14cm vs. 0.23cm, diastolic: 0.11cm vs. 0.14cm); increased mitral E/ A wave relation (6.45 vs. 1.95). Signals of increased end diastolic ventricle pressure, B point in mitral valve tracing in 62.5% and signs of pulmonary hypertension straightening of pulmonary valve (90%) and notching of pulmonary systolic flow (60%) were observed in animals with extensive infarction. CONCLUSION: Doppler echocardiography has a high sensitivity and specificity for detection of chronic extensive infarction. Extensive infarction caused dilatation of left cardiac chambers and showed in Doppler signals of increased end diastolic left ventricular pressure and pulmonary artery pressure.
Resumo:
After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.
Resumo:
OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.
Resumo:
Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.