956 resultados para ion beam implantation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

一种高性能多极双维位置灵敏平行板雪崩计数器(multi-plate parallel plate avalanchecounter,MPPAC)在兰州中能重离子加速器放射性次级束流线(radioactive ion beam line in lanzhou,RIBLL)上被应用,由二次雪崩带来的高增益使它很适合探测较高能量的较轻粒子,它主要由1个中心阳极,x,y位置栅极和2个阴极组成,位置信号由x,y位置栅极采用电荷分除法读出,使用异丁烷工作气体,气压650Pa,阳极+400V,阴极-350V时,对于α粒子位置分辨为0.55mm(半高全宽度,fwhm),位置线性色散远好于±0.2mm,探测效率大于99.2%,同时,也研究了位置分辨与阳极、阴极电压的关系,与放大器成形时间常数的依赖,随工作气压变化等。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Laser-induced fragmentation of C-60 has been studied using a time-of-flight mass spectrometric technique. The average kinetic energies of fragment ions C-n(+) (n <= 58) have been extracted from the measured full width at half maximum (FWHM) of ion beam profiles. The primary formation mechanism of small fragment ion C-n(+) (n < 30) is assumed to be a two-step fragmentation process: C60 sequential decay to unstable C-30(+) ion and the binary fission of C-30(+). Considering a second photo absorption process in the later part of laser pulse duration, good agreement is achieved between experiment and theoretical description of photoion formation. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new measurement of proton resonance scattering on Be-7 was performed tip to the center-of-mass energy of 6.7 MeV using the low-energy RI beam facility CRIB (CNS Radioactive Ion Beam separator) at the Center for Nuclear Study of the University of Tokyo. The excitation function of Be-7 + p elastic scattering above 3.5 MeV was measured Successfully for the first time, providing important information about the resonance structure of the B-8 nucleus. The resonances are related to the reaction rate of Be-7(p.gamma)B-8. which is the key reaction in solar B-8 neutrino production. Evidence for the presence of two negative parity states is presented. One of them is a 2(-) state observed as a broad s-wave resonance, the existence of which had been questionable. Its possible effects on the determination of the astrophysical S-factor of Be-7(p.gamma)B-8 at solar energy are discussed. The other state had not been observed in previous measurements, and its spin and parity were determined as 1(-). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The excited states in 22Mg have been investigated by the resonant elastic scattering of 21Na + p. A 4.0 MeV/nucleon 21Na beam was separated by the Center for Nuclear Study (CNS) radioactive ion beam separator (CRIB) and then used to bombard a thick (CH2)n target. The energy spectra of recoiled protons were measured at scattering angles of θc.m. ≈ 172◦ , 146◦, and 134◦, respectively. A wide energy-range of excitation function in 22Mg (up to Ex ∼ 8.9 MeV) was obtained simultaneously with a thick-target method, and a state at 7.06 MeV was newly observed. The resonant parameters were deduced from an R-matrix analysis of the center-of-mass (c.m.) differential cross-section data with a SAMMY-M6-BETA code. The astrophysical resonant reaction rate for the 18Ne(α,p)21Na reactionwas recalculated based on the present parameters. Generally speaking, the present rates are much smaller than the previous ones.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u, Ar-36 delivered by CSRm were injected into CSRe. The revolution periods of the stored ions, which depend on the mass-to-charge ratios of the stored ions, were measured with a time-of-flight detector system. The results show that the mass resolution around 8 x 10(-6) for Delta m/m is achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The construction and commissioning of HIRFL-CSR were finished in 2007. From 2000 to 2005 the subsystem and key devices of CSR were successfully fabricated, such as magnet, power supply, UHV system, e-cooler, electric-static deflector with the septum of 0.1 mm, and the fast-pulse kicker with the rise time of 150 ns. After that the CSR commissioning activities were performed in 2006 and 2007, including the accumulation of those heavy ions of C, Ar, Kr and Xe by the combination of stripping injection (STI) or multiple multi-turn injection (MMI) and e-cooling with a hollow e-beam, wide energy-range synchrotron ramping by changing the RF harmonic-number at mid-energy, the beam stacking in the experimental ring CSRe, the RIBs mass-measurement with the isochronous-mode in CSRe by using the time-of-flight method, and the ion beam slow-extraction from CSRm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The total reaction cross section (1724 +/- 93 mb) of B-17 at the energy of 43.7 A MeV on C target has been measured by using the transmission method at the Radioactive Ion Beam Line in Lanzhou (RIBLL). Assuming B-17 consists of a core B-15 plus two halo neutrons, the total cross section of B-17 on C target was calculated with the zero-range Glauber model, where double Gaussian density distributions and Gaussian plus HO density distributions were used. It can fit the experimental data very well. The characteristic of halo structure for B-17 was found with a large diffusion of the neutrons density distribution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We briefly introduce the current status and progress in the field of radioactive ion beam physics and the study of super-heavy nuclei. Some important problems and research directions are outlined, such as the sub-barrier fusion reaction, the direct reaction at Fermi energy and high energies, the property of nuclei at drip-lines, new magic numbers and new collective motion modes for unstable nuclei and the synthesis and study of the super-heavy nuclei.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reaction cross section of B-17 on C-12 target at (43.7 +/- 2.4) MeV/u has been measured at the Radioactive Ion Beam Line in Lanzhou (RIBLL). The root-mean-square matter radius (R-rms) was deduced to be (2.92 +/- 0.10) fm, while the R-rms of the core and the valence neutron distribution are 2.28 fm and 5.98 fm respectively. Assuming a "core plus 2n" structure in B-17, the mixed configuration of (2s(1/2)) and (1d(5/2)) of the valence neutrons is studied and the s-wave spectroscopic factor is found to be (80 +/- 21)%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Charge state distribution of 0.8MeV/u uranium ions after transmission through a thin carbon foil has been studied. It is observed that the charge state distribution is equilibrated after the uranium ions have passed through a 15 mu g/cm(2) carbon foil. The equilibrated average charge state is 33.72 and the charge equilibration time of uranium ions in carbon foil is less than 5.4fs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

DNA damage and cell reproductive death determined by alkaline comet and clonogenic survival assays were examined in Lewis lung carcinoma cells after exposure to 89.63 MeV/u carbon ion and 6 MV X-ray irradiations, respectively. Based on the survival data, Lewis lung carcinoma cells were verified to be more radiosensitive to the carbon ion beam than to the X-ray irradiation. The relative biological effectiveness (RBE) value, which was up to 1.77 at 10% survival level, showed that the DNA damage induced by the high-LET carbon ion beam was more remarkable than that induced by the low-LET X-ray irradiation. The dose response curves of '' Tail DNA (%)'' (TD) and "Olive tail moment" (OTM) for the carbon ion irradiation showed saturation beyond about 8 Gy. This behavior was not found in the X-ray curves. Additionally, the carbon ion beam produced a lower survival fraction at 2 Gy (SF2) value and a higher initial Olive tail moment 2 Gy (OTM2) than those for the X-ray irradiation. These results suggest that carbon ion beams having high-LET values produced more severe cell reproductive death and DNA damage in Lewis lung carcinoma cells in comparison with X-rays and comet assay might be an effective predictive test even combining with clonogenic assay to assess cellular radio sensitivity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Large-sized CsI (Tl) single crystals, similar to phi 100 mm x 350 mm, have been grown successfully, and this CsI(Tl) coupled with PD has been successfully utilized at RIBLL (the Radioactive Ion Beam Line in Lanzhou) to measure the energy of heavy ions as a stopping detector. The performances of CsI(Tl) detector coupled with PD and APD have been tested and compared, including the temperature dependence of scintillating light yield

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main ion-beam acceleration facilities and research activities at the Institute of Modern Physics (IMP), Chinese Academy of Sciences are briefly introduced. Some of the biomedical research with heavy ions such as heavy-ion biological effect, basic research related to heavy-ion cancer therapy and radiation breeding at the IMP accelerators are presented.