952 resultados para heart right ventricle double outlet
Resumo:
INTRODUCTION: Complex congenital heart disease is a group of severe conditions. Prenatal diagnosis has implications on morbidity and mortality for most severe conditions. The purpose of this work was to evaluate the influence of prenatal diagnosis and distance of residence and birth place to a reference center, on immediate morbidity and early mortality of complex congenital heart disease. MATERIAL AND METHODS: Retrospective study of complex congenital heart disease patients of our Hospital, born between 2007 and 2012. RESULTS: There were 126 patients born with complex congenital heart disease. In 95%, pregnancy was followed since the first trimester, with prenatal diagnosis in 42%. There was a statistically significant relation between birth place and prenatal diagnosis. Transposition of great arteries was the most frequent complex congenital heart disease (45.2%), followed by pulmonary atresia with ventricular septal defect (17.5%) and hypoplastic left ventricle (9.5%). Eighty-two patients (65.1%) had prostaglandin infusion and 38 (30.2%)were ventilated before an intervention. Surgery took place in the neonatal period in 73%. Actuarial survival rate at 30 days, 12 and 24 months was 85%, 80% and 75%, respectively. There was no statistically significant relation between prenatal diagnosis and mortality. DISCUSSION: Most patients with complex congenital heart disease did not have prenatal diagnosis. All cases with prenatal diagnosis were born in a tertiary center. Prenatal diagnosis did not influence significantly neonatal mortality, as already described in other studies with heterogeneous complex heart disease. CONCLUSION: prenatal diagnosis of complex congenital heart disease allowed an adequate referral. Most patients with complex congenital heart disease were not diagnosed prenatally. This data should be considered when planning prenatal diagnosis of congenital heart disease.
Resumo:
Background The treatment of infants with bronchiolitis is largely supportive. The role of bronchodilators is controversial. Most studies of the use of bronchodilators have enrolled small numbers of subjects and have examined only short-term outcomes, such as clinical scores. Methods We conducted a randomized, double-blind, controlled trial comparing nebulized single-isomer epinephrine with placebo in 194 infants admitted to four hospitals in Queens-land, Australia, with a clinical diagnosis of bronchiolitis. Three 4-ml doses of 1 percent nebulized epinephrine or three 4-ml doses of normal saline were administered at four-hour intervals after hospital admission. Observations were made at admission and just before, 30 minutes after, and 60 minutes after each dose. The primary outcome measures were the length of the hospital stay and the time until the infant was ready for discharge. The secondary outcome measures were the degree of change in the respiratory rate, the heart rate, and the respiratory-effort score and the time that supplemental oxygen was required. Results There were no significant overall differences between the groups in the length of the hospital stay (P=0.16) or the time until the infant was ready for discharge (P=0.86). Among infants who required supplemental oxygen and intravenous fluids, the time until the infant was ready for discharge was significantly longer in the epinephrine group than in the placebo group (P=0.02). The need for supplemental oxygen at admission had the greatest influence on the score for severity of illness and strongly predicted the length of the hospital stay and the time until the infant was ready for discharge (P
Investigation of signaling pathways that mediate the inotropic effect of urotensin-II in human heart
Resumo:
Objective: This study investigated signaling pathways that may contribute to the potent positive inotropic effect of human urotensin-II (hU-II) in human isolated right atrial trabeculae obtained from patients with coronary artery disease. Methods: Trabeculae were set up in tissue baths and stimulated to contract at 1 Hz. Tissues were incubated with 20 nM hU-II with or without phorbol 12-myristate 13-acetate (PMA, 10 muM) to desensitize PKC, the PKC inhibitor chelerythrine (10 muM), 10 muM 4alpha-phorbol that does not desensitize PKC, the myosin light chain kinase inhibitor wortmannin (50 nM, 10 muM), or the Rho kinase inhibitor Y-27632 (0.1 - 10 muM). Activated RhoA was determined by affinity immunoprecipitation, and phosphorylation of signaling proteins was determined by SDS-PAGE. Results: hU-II caused a potent positive inotropic response in atrial trabeculae, and this was concomitant with increased phosphorylation of regulatory myosin light chain (MLC-2, 1.8 +/- 0.4-fold, P < 0.05, n = 6) and PKCalpha/betaII (1.4 +/- 0.2-fold compared to non-stimulated controls, P < 0.05, n = 7). Pretreatment of tissues with PMA caused a marked reduction in the inotropic effect of hU-II, but did not affect hU-II-mediated phosphorylation of MLC-2. The inotropic response was inhibited by chelerythrine, but not 4alpha-phorbol or wortmannin. Although Y-27632 also reduced the positive inotropic response to hU-II, this was associated with a marked reduction in basal force of contraction. RhoA. GTP was immunoprecipitated in tissues pretreated with or without hU-II, with findings showing no detectable activation of RhoA in the agonist stimulated tissues. Conclusions: The findings indicated that hU-II increased force of contraction in human heart via a PKC-dependent mechanism and increased phosphorylation of MLC-2, although this was independent of PKC. The positive inotropic effect was independent of myosin light chain kinase and RhoA-Rho kinase signaling pathways. (C) 2004 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Resumo:
Urotensin-II (UII) is a highly potent endogenous peptide within the cardiovascular system. Through stimulation of Galphaq-coupled UT receptors, UII mediates contraction of vascular smooth muscle and endothelial-dependent vasorelaxation, and positive inotropy in human right atrium and ventricle. A pathogenic role of the UT receptor system is emerging in cardiovascular disease states, with evidence for upregulation of the UT receptor system in patients with congestive heart failure (CHF), pulmonary hypertension, cirrhosis and portal hypertension, and chronic renal failure. In vitro and in vivo studies show that under pathophysiological conditions, UII might contribute to cardiomyocyte hypertrophy, extracellular matrix production, enhanced vasoconstriction, vascular smooth muscle cell hyperplasia, and endothelial cell hyper-permeability. Single nucleotide polymorphisms of the UII gene may also impart a genetic predisposition of patients to diabetes. Therefore, the UT receptor system is a potential therapeutic target in the treatment of cardiac, pulmonary, and renal diseases. UT receptor antagonists are currently being developed to prevent and/or reverse the effects of over-activated UT receptors by the endogenous ligand. This review describes UII peptide and converting enzymes, and UT receptors in the cardiovascular system, focusing on pathophysiological roles of UII in the heart and blood vessels. (C) 2004 Elsevier Inc. All rights reserved,
Resumo:
Background - Specific treatments targeting the pathophysiology of hypertensive heart disease are lacking. As aldosterone has been implicated in the genesis of myocardial fibrosis, hypertrophy, and dysfunction, we sought to determine the effects of aldosterone antagonism on myocardial function in hypertensive patients with suspected diastolic heart failure by using sensitive quantitative echocardiographic techniques in a randomized, double-blinded, placebo-controlled study. Methods and Results - Thirty medically treated ambulatory hypertensive patients (19 women, age 62 +/- 6 years) with exertional dyspnea, ejection fraction >50%, and diastolic dysfunction (E/A 250m/sec) and without ischemia were randomized to spironolactone 25 mg/d or placebo for 6 months. Patients were overweight (31 +/- 5 kg/m(2)) with reduced treadmill exercise capacity (6.7 +/- 2.1 METS). Long-axis strain rate (SR), peak systolic strain, and cyclic variation of integrated backscatter (CVIB) were averaged from 6 walls in 3 standard apical views. Mean 24-hour ambulatory blood pressure at baseline (133 +/- 17/80 +/- 7mm Hg) did not change in either group. Values for SR, peak systolic strain, and CVIB were similar between groups at baseline and remained unchanged with placebo. Spironolactone therapy was associated with increases in SR (baseline: -1.57 +/- 0.46 s(-1) versus 6-months: -1.91 +/- 0.36 s(-1), P < 0.01), peak systolic strain (-20.3 &PLUSMN; 5.0% versus -26.9 &PLUSMN; 4.3%, P < 0.001), and CVIB (7.4 +/- 1.7dB versus 8.6 +/- 1.7 dB, P = 0.08). Each parameter was significantly greater in the spironolactone group compared with placebo at 6 months (P = 0.05, P = 0.02, and P = 0.02, respectively), and the increases remained significant after adjusting for baseline differences. The increase in strain was independent of changes in blood pressure with intervention. The spironolactone group also exhibited reduction in posterior wall thickness (P = 0.04) and a trend to reduced left atrial area (P = 0.09). Conclusions - Aldosterone antagonism improves myocardial function in hypertensive heart disease.
Resumo:
Subclinical left ventricular (W) dysfunction may be identified by reduced longitudinal contraction. We sought to define the effects of subclinical LV dysfunction on radial contractility in 53 patients with diabetes mellitus with no LV hypertrophy, normal ejection fraction and no ischaemia as assessed by dobutamine echocardiography, in comparison with age-matched controls. Radial peak myocardial systolic velocity (S-m) and early diastolic velocity (E-m), strain and strain rate were measured in the mid-posterior and mid-anteroseptal walls in parasternal views and each variable was averaged for individual patients (radial contractility). These variables were also measured in the mid-posterior and mid-anteroseptal walls in the apical long-axis view and each variable was averaged for individual patients (longitudinal contractility). Mean radial S-m, strain and strain rate were significantly increased in diabetic patients (2.9+/-0.6 cm/s, 28+/-5% and 1.8+/-0.4 s(-1) respectively) compared with controls (2.4+/-0.7 cm/s, 23+/-4% and 1.6+/-0.3 s(-1) respectively; all P<0.001), but there was no difference in E-m (3.3&PLUSMN;1.2 compared with 3.1&PLUSMN;1.1 cm/s, P=not significant). In contrast, longitudinal S-m, E-m, strain and strain rate were significantly lower in diabetic patients (3.6&PLUSMN;1.1 cm/s, 4.3&PLUSMN;1.6 cm/s, 21&PLUSMN;4% and 1.6&PLUSMN;0.3 s(-1) respectively) than in controls (4.3&PLUSMN;1.0 cm/s, 5.7&PLUSMN;2.3 cm/s, 26&PLUSMN;4% and 1.9&PLUSMN;0.3 s(-1) respectively; all P<0.00 1). Thus radial contractility appears to compensate for reduced longitudinal contractility in subclinical LV dysfunction occurring in the absence of ischaemia or LV hypertrophy.
Resumo:
The assessment of left ventricular (LV) dysfunction has become the most frequent indication for echocardiography, a growth that has been driven by the epidemic of heart failure. The value of echocardiography for assessing LV dysfunction is unquestionable, the quantification of both LV systolic and diastolic dysfunction being a reliable indicator of mortality. 1,2 Nonetheless, whereas the ejection fraction and diastolic assessment are important clinical parameters, they are highly dependent on loading and may produce abnormal results under unusual loading conditions. Moreover, in a number of situations where the LV is evaluated, although the overall function is an important finding, the referring clinician is really requesting an assessment of the nature of the underlying myocardial tissue (Table 1). Indeed, in some situations (eg, among family members of patients with a cardiomyopathy) questions arise about the presence of pathology despite the presence of normal ventricular function. Traditionally, it has been difficult to obtain this information because of the lack of sufficiently sensitive parameters, but a number of new developments have shown such success in this area that the clinical application of tools to assess the myocardium in routine practice appears finally to be a realistic proposition.
Resumo:
Objective To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. Design Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. Procedure All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. Results These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the maximising method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific normal left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. Conclusion These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.
Resumo:
Objective To determine the diagnostic accuracy of prenatal fetal echocardiography. Methods The study was a retrospective chart review of 190 consecutive patients over a 3-year period from November 1998 to February 2002 of all women referred to the Maternal Fetal Medicine unit, Mater Mothers Hospital, for fetal echocardiography. The prenatal diagnosis was compared with the postnatal diagnosis made by postnatal echocardiography, surgical findings or post-mortem. The accuracy of prenatal diagnosis was described on a predetermined 4-point scale. Results Of the 89 patients, for whom complete diagnostic follow-up was available, there was complete agreement between the prenatal and postnatal diagnosis in 63 cases, minor discrepancies in 25 cases and major disagreement in 1 case. Conclusions In experienced hands, fetal echocardiography is accurate and allows medical staff and patients information in order manage a pregnancy appropriately. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Objective: To understand the basis of the effectiveness of carvedilol in heart failure by determining its specific properties at human heart and beta(2)-adrenoceptors. Methods: The positive inotropic effects of noradrenaline (in the presence of the beta(2)-selective antagonist ICI118551) and adrenaline (in the presence of the beta(1)-selective antagonist CGP20712), mediated through beta(1)- and beta(2)-adrenoceptors, respectively, were investigated in atrial and ventricular trabeculae. The patch-clamp technique was used to investigate effects of noradrenaline and adrenaline on L-type Ca2+ current in human atrial myocytes. Results: Carvedilol was a 13-fold more potent competitive antagonist of the effects of adrenaline at 1 2-adrenoceptors (-logK(B) = 10.13 +/- 0.08) than of noradrenaline at beta(1)-adrenoceptors (-logK(B) = 9.02 +/- 0.07) in human right atrium. Chronic carvedilol treatment of patients with non-terminal heart failure reduced the inotropic sensitivity of atrial trabeculae to noradrenaline and adrenaline 5.6-fold and 91.2-fold, respectively, compared to beta(1)-blocker-treated patients, consistent with persistent preferential blockade of beta(2)-adrenoceptors. In terminal heart failure carvedilol treatment reduced 1.8-fold and 25.1-fold the sensitivity of right ventricular trabeculae to noradrenaline and adrenaline, respectively, but metoprolol treatment did not reduce the sensitivity to the catecholamines. Increases of current (I-Ca,I-L) produced by noradrenaline and adrenaline were not different in atrial myocytes obtained from non-terminal heart failure patients treated with metoprolol or carvedilol, consistent with dissociation of both beta-blockers from the receptors. Conclusions: Carvedilol blocks human cardiac beta(2)-adrenoceptors more than beta(1)-adrenoceptors, thereby conceivably contributing to the beneficial effects in heart failure. The persistent blockade of beta-adrenoceptors is attributed to accumulation of carvedilol in cardiac tissue. (c) 2005 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Resumo:
Objectives: In this paper, we present a unified electrodynamic heart model that permits simulations of the body surface potentials generated by the heart in motion. The inclusion of motion in the heart model significantly improves the accuracy of the simulated body surface potentials and therefore also the 12-lead ECG. Methods: The key step is to construct an electromechanical heart model. The cardiac excitation propagation is simulated by an electrical heart model, and the resulting cardiac active forces are used to calculate the ventricular wall motion based on a mechanical model. The source-field point relative position changes during heart systole and diastole. These can be obtained, and then used to calculate body surface ECG based on the electrical heart-torso model. Results: An electromechanical biventricular heart model is constructed and a standard 12-lead ECG is simulated. Compared with a simulated ECG based on the static electrical heart model, the simulated ECG based on the dynamic heart model is more accordant with a clinically recorded ECG, especially for the ST segment and T wave of a V1-V6 lead ECG. For slight-degree myocardial ischemia ECG simulation, the ST segment and T wave changes can be observed from the simulated ECG based on a dynamic heart model, while the ST segment and T wave of simulated ECG based on a static heart model is almost unchanged when compared with a normal ECG. Conclusions: This study confirms the importance of the mechanical factor in the ECG simulation. The dynamic heart model could provide more accurate ECG simulation, especially for myocardial ischemia or infarction simulation, since the main ECG changes occur at the ST segment and T wave, which correspond with cardiac systole and diastole phases.
Resumo:
OBJECTIVES The purpose of this research was to identify the determinants of right ventricular (RV) dysfunction in overweight and obese subjects. BACKGROUND Right ventricular dysfunction in obese subjects is usually ascribed to comorbid diseases, especially obstructive sleep apnea. We used tissue Doppler imaging to identify the determinants of RV dysfunction in overweight and obese subjects. METHODS Standard and tissue Doppler echocardiography was performed in 112 overweight (body mass index [BMI] 25 to 29.9 kg/m(2)) or obese (BMI >30 kg/m(1)) subjects and 36 referents (BMI 35 kg/m(2) had reduced RV function compared with referent subjects, evidenced by reduced s(m) (6.5 +/- 2.4 cm/s vs. 10.2 +/- 1.5 cm/s, p < 0.001), peak strain (-21 +/- 4% vs. -28 +/- 4%, p < 0.001), peak strain rate (-1.4 +/- 0.4 s(-1) vs. -2.0 +/- 0.5 s(-1), p < 0.001), and e(m) (6.8 +/- 2.4 cm/s vs. -10.3 +/- 2.5 cm/s, p < 0.001), irrespective of the presence of sleep apnea. Similar but lesser degrees of reduced systolic function (p < 0.05) were present in overweight (BMI 25 to 29.9 kg/m(2)) and mildly obese (BMI 30 to 35 kg/m(2)) groups. Differences in RV e(m), s(m), and strain indexes were demonstrated between the severely versus overweight and mildly obese groups (p < 0.05). Body mass index remained independently related to RV changes after adjusting for age, log insulin, and mean arterial pressures. In obese patients, these changes were associated with reduced exercise capacity but not the duration of obesity and presence of sleep apnea or its severity. CONCLUSIONS Increasing BMI is associated with increasing severity of RV dysfunction in overweight and obese subjects without overt heart disease, independent of sleep apnea.
Resumo:
Mock circulation loops are used to evaluate the performance of cardiac assist devices prior to animal and clinical testing. A compressible, translucent silicone ventricle chamber that mimics the exact size, shape and motion of a failing heart is desired to assist in flow visualization studies around inflow cannulae during VAD support. The aim of this study was therefore to design and construct a naturally shaped flexible left ventricle and evaluate its performance in a mock circulation loop. The ventricle shape was constructed by the use of CT images taken from a patient experiencing cardiomyopathic heart failure and used to create a 3D image and subsequent mould to produce a silicone ventricle. Different cardiac conditions were successfully simulated to validate the ventricle performance, including rest, left heart failure and VAD support.
Resumo:
2010 Mathematics Subject Classification: Primary 18G35; Secondary 55U15.
Resumo:
The objective of this study was to investigate the nature and biomechanical properties of collagen fibers within the human myocardium. Targeting cardiac interstitial abnormalities will likely become a major focus of future preventative strategies with regard to the management of cardiac dysfunction. Current knowledge regarding the component structures of myocardial collagen networks is limited, further delineation of which will require application of more innovative technologies. We applied a novel methodology involving combined confocal laser scanning and atomic force microscopy to investigate myocardial collagen within ex-vivo right atrial tissue from 10 patients undergoing elective coronary bypass surgery. Immuno-fluorescent co-staining revealed discrete collagen I and III fibers. During single fiber deformation, overall median values of stiffness recorded in collagen III were 37±16% lower than in collagen I [p<0.001]. On fiber retraction, collagen I exhibited greater degrees of elastic recoil [p<0.001; relative percentage increase in elastic recoil 7±3%] and less energy dissipation than collagen III [p<0.001; relative percentage increase in work recovered 7±2%]. In atrial biopsies taken from patients in permanent atrial fibrillation (n=5) versus sinus rhythm (n=5), stiffness of both collagen fiber subtypes was augmented (p<0.008). Myocardial fibrillar collagen fibers organize in a discrete manner and possess distinct biomechanical differences; specifically, collagen I fibers exhibit relatively higher stiffness, contrasting with higher susceptibility to plastic deformation and less energy efficiency on deformation with collagen III fibers. Augmented stiffness of both collagen fiber subtypes in tissue samples from patients with atrial fibrillation compared to those in sinus rhythm are consistent with recent published findings of increased collagen cross-linking in this setting.