966 resultados para haptic motion control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro-robotic cell injection is typically performed manually by a trainedbio-operator, and success rates are often low. To enhance bio-operator performance during real-time cell injection, our earlier work introduced a haptically-enabled micro-robotic cell injection system. The system employed haptic virtual fixtures to provide haptic guidance according to articular performance metrics. This paper extends the work by replicating the system within a virtual reality (VR) environment for bio-operator training. Using the virtual environment, the bio-operator is able to control the virtual injection process in the same way they would with the physical haptic micro-robotic cell injection system, while benefiting from the enhanced visualisation capabilities offered by the 3D VR environment. The system is achieved using cost-effective components offering training at much lower cost than using the physical system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to design and develop an optimal motion cueing algorithm (MCA) based on the genetic algorithm (GA) that can generate high-fidelity motions within the motion simulator's physical limitations. Both, angular velocity and linear acceleration are adopted as the inputs to the MCA for producing the higher order optimal washout filter. The linear quadratic regulator (LQR) method is used to constrain the human perception error between the real and simulated driving tasks. To develop the optimal MCA, the latest mathematical models of the vestibular system and simulator motion are taken into account. A reference frame with the center of rotation at the driver's head to eliminate false motion cues caused by rotation of the simulator to the translational motion of the driver's head as well as to reduce the workspace displacement is employed. To improve the developed LQR-based optimal MCA, a new strategy based on optimal control theory and the GA is devised. The objective is to reproduce a signal that can follow closely the reference signal and avoid false motion cues by adjusting the parameters from the obtained LQR-based optimal washout filter. This is achieved by taking a series of factors into account, which include the vestibular sensation error between the real and simulated cases, the main dynamic limitations, the human threshold limiter in tilt coordination, the cross correlation coefficient, and the human sensation error fluctuation. It is worth pointing out that other related investigations in the literature normally do not consider the effects of these factors. The proposed optimized MCA based on the GA is implemented using the MATLAB/Simulink software. The results show the effectiveness of the proposed GA-based method in enhancing human sensation, maximizing the reference shape tracking, and reducing the workspace usage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improvised Explosive Devices (IEDs) are reported as the number one cause of injury and death for allied troops in the current theater of operation. Current stand-off technologies for Counter IED (CIED) tasks rely on robotic platforms that have not improved in capability over the past decade to combat the ever increasing threat of IEDs. While they provide operational capability, the effectiveness of these platforms is limited. This is because they primarily utilise video and audio feedback, and require extensive training and specialist operators. Recent operational experience has demonstrated the need for robotic systems that are highly capable, yet easily operable for high fidelity manipulation. Force feedback provides an operator with more intuitive control of a robotic system. This sense of touch allows an operator to obtain a sense of feel from a stand-off location of what the robot touches or grasps through a human-robot interface. This paper reports the design and development of a Haptically-Enabled Counter IED robotic system that was funded by the Australian Defence Force. The presented work focuses on the design methodology for the system, and provides the results of the manipulator analysis and trial outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we examine the nonlinear control method based on the saturation phenomenon and of systems coupled with quadratic nonlinear ties applied to a shear-building portal plane frame foundation that supports an unbalanced direct cut-rent with limited power supply (non-ideal system). We analyze the equations of motion by using the method of averaging and numerical simulation. The interaction of the non-ideal structure with the saturation controller may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the systems. Special attention is focused on passage through resonance when the non-ideal excitation frequency is near the portal frame natural frequency and when the non-ideal system frequency is approximately twice the controller frequency (two-to-one internal resonance).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a load transportation system in platforms or suspended by cables is considered. It is a monorail device and is modelled as an inverted pendulum built on a car driven by a DC motor. The governing equations of motion were derived via Lagrange's equations. In the mathematical model we consider the interaction between the DC motor and the dynamical system, that is, we have a so-called non-ideal periodic problem. The problem is analysed and we also developed an optimal linear control design to stabilize the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this Letter, an optimal control strategy that directs the chaotic motion of the Rossler system to any desired fixed point is proposed. The chaos control problem is then formulated as being an infinite horizon optimal control nonlinear problem that was reduced to a solution of the associated Hamilton-Jacobi-Bellman equation. We obtained its solution among the correspondent Lyapunov functions of the considered dynamical system. (C) 2004 Elsevier B.V All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a loads transportation system in platforms or suspended by cables is considered. It is a monorail device and is modeled as an inverted pendulum built on a car driven by a dc motor the governing equations of motion were derived via Lagrange's equations. In the mathematical model we consider the interaction between the dc motor and the dynamical system, that is, we have a so called nonideal periodic problem. The problem is analyzed, qualitatively, through the comparison of the stability diagrams, numerically obtained, for several motor torque constants. Furthermore, we also analyze the problem quantitatively using the Floquet multipliers technique. Finally, we devise a control for the studied nonideal problem. The method that was used for analysis and control of this nonideal periodic system is based on the Chebyshev polynomial exponsion, the Picard iterative method, and the Lyapunov-Floquet transformation (L-F transformation). We call it Sinha's theory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article uses an anchor metaphor to explain the dynamic interplay between the human body's active uses of nonrigid tools to mediate information about its adjacent environment to enhance postural control. The author used an anchor system (ropes attached to varying weights resting on the floor) to test blindfolded adults who performed a restricted-balance task (30 s one-foot standing). Participants were tested while holding the anchors under a variety of weight conditions (125 g, 250 g, 500 g, and I kg) and again during a baseline condition (no anchors). When compared with the baseline condition, there was a significant reduction in the amount of body sway across the anchor conditions. The author found that mechanical support provided by the anchor system was secondary to its haptic exploratory function and that an individual can use the anchoring strategy with a dual purpose: for resting and for reorientation after intrinsic disruptions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microactuator made from poly(vinylidene fluoride) (PVDF), a piezoelectric polymer, was fabricated to control the gas flow rate through a glass micronozzle. The actuator was formed by gluing together two PVDF sheets with opposite polarization directions. The sheets were covered with thin conducting films on one side, that were then used as electrodes to apply an electric field to move the valve. The actuator has a rectangular shape, 3 mm x 6 mm. The device was incorporated with a micronozzle fabricated by a powder blasting technique. Upon applying a DC voltage across the actuator electrodes, one sheet expands while the other contracts, generating an opening motion. A voltage of +300 V DC was used to open the device by moving the actuator 30 mu m, and a voltage of -200 V DC was used to close the device by moving the actuator 20 mu m lower than the relaxed position. Flow measurements were performed in a low-pressure vacuum system, maintaining the microvalve inlet pressure constant at 266 Pa. Tests carried out with the actuator in the open position and with a pressure ratio (inlet pressure divided by outlet pressure) of 0.5, indicated a flow rate of 0.36 sccm. In the closed position, and with a pressure ratio of 0.2, a flow rate of 0.32 sccm was measured.