784 resultados para f!ber optic sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work provides a general description of the multi sensor data fusion concept, along with a new classification of currently used sensor fusion techniques for unmanned underwater vehicles (UUV). Unlike previous proposals that focus the classification on the sensors involved in the fusion, we propose a synthetic approach that is focused on the techniques involved in the fusion and their applications in UUV navigation. We believe that our approach is better oriented towards the development of sensor fusion systems, since a sensor fusion architecture should be first of all focused on its goals and then on the fused sensors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a computer vision system that associates omnidirectional vision with structured light with the aim of obtaining depth information for a 360 degrees field of view. The approach proposed in this article combines an omnidirectional camera with a panoramic laser projector. The article shows how the sensor is modelled and its accuracy is proved by means of experimental results. The proposed sensor provides useful information for robot navigation applications, pipe inspection, 3D scene modelling etc

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catadioptric sensors are combinations of mirrors and lenses made in order to obtain a wide field of view. In this paper we propose a new sensor that has omnidirectional viewing ability and it also provides depth information about the nearby surrounding. The sensor is based on a conventional camera coupled with a laser emitter and two hyperbolic mirrors. Mathematical formulation and precise specifications of the intrinsic and extrinsic parameters of the sensor are discussed. Our approach overcomes limitations of the existing omni-directional sensors and eventually leads to reduced costs of production

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Par Compliance, on entend l'ensemble des mesures organisationnelles d'une entreprise qui visent à assurer le respect des règles par l'entreprise et ses collaborateurs. Dans le secteur privé - surtout dans les banques et les assurances - la Compliance est un concept bien établi et le poste du Compliance Officer apparaît clairement dans l'organigramme des entreprises. Ce terme apparaît aussi de temps à autre au sein de l'administration fédérale, en relation avec la politique de gestion des risques et le système de contrôle interne (SCI) ; mais une introduction effective de la Compliance n'y a pas encore eu lieu (jusqu'ici). Les Américains ont l'habitude de dire « if you think compliance is expensive, try non compliance ». Cette déclaration, apparemment valable pour le secteur privé, peut-elle cependant être transposée telle quelle au secteur public ? L'introduction d'un système de management tel que la Compliance apporterait-elle effectivement une plus-value par rapport aux systèmes existants afin d'éviter les risques engendrant des conséquences juridiques ou causant une mauvaise réputation suite au non-respect de règles par des collaborateurs ? La présente étude se penche sur ces questions et analyse, sur la base de documents et d'interviews, quels éléments de la Compliance existent au niveau de la Confédération et au sein de l'Office fédéral de la santé publique (OFSP) et s'ils sont propres à atteindre les objectifs visés par la Compliance. Dans plusieurs domaines, on a pu constater des défauts et, par conséquent, un gros potentiel d'amélioration. Le problème principal est l'absence d'organisation au niveau de la Compliance. Cela complique la vue d'ensemble des risques juridiques et de ceux pouvant causer une mauvaise réputation qui existent au niveau de la Confédération et à l'OFSP et rend impossible un management homogène de ces risques. En conséquence et dans l'état actuel des choses, il pourrait s'avérer difficile d'éviter de manière durable la réalisation des risques susmentionnés au moyen des systèmes existants. D'un autre côté, la politique de gestion des risques au sein de la Confédération et l'introduction d'un système de contrôle interne (SCI) ont représenté les premiers pas en direction d'un système de gestion des risques intégré. La Compliance serait un complément idéal et pourrait - dans la mesure où la direction de l'Office la soutient et donne le bon exemple - contribuer à la réduction des risques décrits ci-dessus non seulement au niveau de la Confédération mais encore au sein de l'OFSP. La présente étude ne vise pas pour autant à critiquer les systèmes établis, mais bien plus à montrer le potentiel d'amélioration dont on pourrait tirer profit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The major active retinoid, all-trans retinoic acid, has long been recognized as critical for the development of several organs, including the eye. Mutations in STRA6, the gene encoding the cellular receptor for vitamin A, in patients with Matthew-Wood syndrome and anophthalmia/microphthalmia (A/M), have previously demonstrated the importance of retinol metabolism in human eye disease. We used homozygosity mapping combined with next-generation sequencing to interrogate patients with anophthalmia and microphthalmia for new causative genes. We used whole-exome and whole-genome sequencing to study a family with two affected brothers with bilateral A/M and a simplex case with bilateral anophthalmia and hypoplasia of the optic nerve and optic chiasm. Analysis of novel sequence variants revealed homozygosity for two nonsense mutations in ALDH1A3, c.568A>G, predicting p.Lys190*, in the familial cases, and c.1165A>T, predicting p.Lys389*, in the simplex case. Both mutations predict nonsense-mediated decay and complete loss of function. We performed antisense morpholino (MO) studies in Danio rerio to characterize the developmental effects of loss of Aldh1a3 function. MO-injected larvae showed a significant reduction in eye size, and aberrant axonal projections to the tectum were noted. We conclude that ALDH1A3 loss of function causes anophthalmia and aberrant eye development in humans and in animal model systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El grup de Visió per Computador i Robòtica (VICOROB) disposa de varis robotssubmarins per a la recerca i inspecció subaquàtica. Recentment s’ha adquiritun sensor sonar d’escombrat lateral el qual s’utilitza per realitzar imatgesacústiques del fons marí quan aquest es mou principalment a velocitat constanti mantenint el rumb.Els robots del grup VICOROB estan equipats amb diferents tipus de sensors icàmeres per analitzar el fons marí. Aquest sensors són de gran qualitat ipermeten conèixer de manera bastant satisfactòria l’entorn a les proximitats delrobot. Freqüentment però, aquest sensors estant sotmesos a diferentsrestriccions depenent de la seva naturalesa de funcionament, de tal maneraque es necessària la seva combinació per resoldre determinats problemes endiferents situacions.Amb aquest projecte, es pretén integrar un nou sistema de captura d’imatgessonores del fons marí, en un dels robots. Amb la integració d’aquest nousensor, s’espera obtenir una opció alternativa els sistemes actuals que puguiaportar informació addicional sobre el fons. Aquest sistema podrà ser utilitzatper realitzar tasques per les quals els altres sensors no estant preparats o béper complementar informació d’altres sensor

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To better define the concordance of visual loss in patients with nonarteritic anterior ischemic optic neuropathy (NAION). METHODS The medical records of 86 patients with bilateral sequential NAION were reviewed retrospectively, and visual function was assessed using visual acuity, Goldmann visual fields, color vision, and relative afferent papillary defect. A quantitative total visual field score and score per quadrant were analyzed for each eye using the numerical Goldmann visual field scoring method. RESULTS Outcome measures were visual acuity, visual field, color vision, and relative afferent papillary defect. A statistically significant correlation was found between fellow eyes for multiple parameters, including logMAR visual acuity (P = .01), global visual field (P < .001), superior visual field (P < .001), and inferior visual field (P < .001). The mean deviation of total (P < .001) and pattern (P < .001) deviation analyses was significantly less between fellow eyes than between first and second eyes of different patients. CONCLUSIONS Visual function between fellow eyes showed a fair to moderate correlation that was statistically significant. The pattern of vision loss was also more similar in fellow eyes than between eyes of different patients. These results may help allow better prediction of visual outcome for the second eye in patients with NAION.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radiation optic neuropathy (RON) is a rare, unpredictable, late complication of radiotherapy secondary to obliterative endarteritis. Tumor recurrence has to be ruled out by a clinical and neuroradiological examination. METHODS: Five patients with RON were investigated by magnetic resonance imaging (MRI) during 1992. RESULTS: Radiation-induced lesions of the intracranial visual pathways were easily visible on MRI. Without Gadolinium, a sectorial swelling was detectable, which markedly enhanced with Gadolinium. Intracranial optic nerve was affected in 5/5 cases, optic chiasm in 3/5 cases, and optic tract in 2/5 cases. CONCLUSIONS: MRI is the examination of choice when RON is suspected: it will easily delineate the extent of the lesion, and compression/infiltration by a recurrent tumor will be formally ruled out. A segmental swelling of visual pathway with marked Gadolinium enhancement on MRI is highly suggestive of radionecrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The activity of melanopsin containing intrinsically photosensitive ganglion retinal cells (ipRGC) can be assessed by a means of pupil responses to bright blue (appr.480 nm) light. Due to age related factors in the eye, particularly, structural changes of the lens, less light reaches retina. The aim of this study was to examine how age and in vivo measured lens transmission of blue light might affect pupil light responses, in particular, mediated by the ipRGC. METHODS: Consensual pupil responses were explored in 44 healthy subjects aged between 26 and 68 years. A pupil response was recorded to a continuous 20 s light stimulus of 660 nm (red) or 470 nm (blue) both at 300 cd/m2 intensity (14.9 and 14.8 log photons/cm2/s, respectively). Additional recordings were performed using four 470 nm stimulus intensities of 3, 30, 100 and 300 cd/m2. The baseline pupil size was measured in darkness and results were adjusted for the baseline pupil and gender. The main outcome parameters were maximal and sustained pupil contraction amplitudes and the postillumination response assessed as area under the curve (AUC) over two time-windows: early (0-10 s after light termination) and late (10-30 s after light termination). Lens transmission was measured with an ocular fluorometer. RESULTS: The sustained pupil contraction and the early poststimulus AUC correlated positively with age (p=0.02, p=0.0014, respectively) for the blue light stimulus condition only.The maximal pupil contraction amplitude did not correlate to age either for bright blue or red light stimulus conditions.Lens transmission decreased linearly with age (p<0.0001). The pupil response was stable or increased with decreasing transmission, though only significantly for the early poststimulus AUC to 300 cd/m2 light (p=0.02). CONCLUSIONS: Age did not reduce, but rather enhance pupil responses mediated by ipRGC. The age related decrease of blue light transmission led to similar results, however, the effect of age was greater on these pupil responses than that of the lens transmission. Thus there must be other age related factors such as lens scatter and/or adaptive processes influencing the ipRGC mediated pupil response enhancement observed with advancing age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept that optic nerve fiber loss might be reduced by neuroprotection arose in the mid 1990s. The subsequent research effort, focused mainly on rodent models, has not yet transformed into a successful clinical trial, but provides mechanistic understanding of retinal ganglion cell death and points to potential therapeutic strategies. This review highlights advances made over the last year. In excitotoxicity and axotomy models retinal ganglion cell death has been shown to result from a complex interaction between retinal neurons and Müller glia, which release toxic molecules including tumor necrosis factor alpha. This counteracts neuroprotection by neurotrophins such as nerve growth factor, which bind to p75NTR receptors on Müller glia stimulating the toxic release. Another negative effect against neurotrophin-mediated protection involves the action of LINGO-1 at trkB brain-derived neurotrophic factor (BDNF) receptors, and BDNF neuroprotection is enhanced by an antagonist to LINGO-1. As an alternative to pharmacotherapy, retinal defences can be stimulated by exposure to infrared radiation. The mechanisms involved in glaucoma and other optic nerve disorders are being clarified in rodent models, focusing on retrograde degeneration following axonal damage, excitotoxicity and inflammatory/autoimmune mechanisms. Neuroprotective strategies are being refined in the light of the mechanistic understanding.