983 resultados para current measurement
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objective: Meningococcal disease continues to be a serious public health concern, being associated with high morbidity and mortality rates in many countries from Latin America. In addition to discussing recent changes in the epidemiology of meningococcal disease in the region, we also analyse the development and potential impact of new vaccines on the prevention of meningococcal disease. Methods: MEDLINE, SciELO, LILACS and websites of the national Ministries of Health databases were searched using the terms meningococcal disease, meningococcal epidemiology, Neisseria meningitidis, meningococcal vaccines and the name of Latin America countries, from 1998 to 2008, with emphasis on review articles, clinical trials and epidemiological studies. Results: Epidemiology of meningococcal disease in Latin America is characterized by marked differences from country to country. The overall incidence of meningococcal disease per year varied from less than 0.1 cases per 100,000 inhabitants in countries like Mexico to two cases per 100,000 inhabitants in Brazil. The highest age-specific incidence of meningococcal disease occurred in infants less than 1 year of age. Serogroups B and C were responsible for the majority of cases reported, but the emergence of serogroups W135 and Y was reported in some countries. Serogroup A disease is now rare in Latin America. Discussion: Although a few countries have established meningitis surveillance programs, the information is not uniform, and the quality of the reported data is poor in the majority of the region. The availability of new effective meningococcal conjugate vaccines and promising protein-based vaccine candidates against meningococcus B highlights the importance of a better understanding of the true burden of meningococcal disease in Latin America and also the need for cost-effectiveness studies before incorporating the new meningococcal vaccines to national immunization programs.
Resumo:
Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Several papers on Schistosoma mansoni and Schistosoma japonicum proteomes have been published worldwide in the past few years, representing an emerging field of study. Knowledge of the schistosome proteome may greatly enhance our understanding of schistosome physiological processes at the molecular level, and may provide new models for development of vaccines or drugs. Despite the importance of this approach. schistosome proteomic research in Brazil is still incipient. Here we review the development of schistosome proteomic research around the world and provide an appreciation on the future opportunities in Brazil. (c) 2008 Elsevier B.V. All rights reserved
Resumo:
Background: There is little, though growing, interest in the research area of attitudes held among physicians towards disclosing the diagnosis of dementia and Alzheimer`s disease (AD), or the current practice on AD disclosure. This study aimed to investigate the practice and attitudes of specialized physicians towards AD diagnosis disclosure in Brazil. Methods: A questionnaire was devised to survey the current practice and attitudes regarding diagnosis disclosure of AD in Brazil and sent to specialized physicians (170 geriatricians, 300 neurologists and 500 psychiatrists) by electronic mail. Results: From 970 potential respondents, 181 physicians who usually attend AD patients returned the questionnaire. There were no significant differences between the three specialties regarding the frequency with which they informed patients of their AD diagnosis (p = 0.17). The results revealed that only 44.8% of the physicians would regularly inform the patient of the diagnosis, although 85.6% of these use clear terminology. Despite their usual practice, 76.8% would want to know their diagnosis if they themselves were affected by AD. Conclusions: Disclosure of AD diagnosis is not common among specialized physicians in Brazil and different factors are involved. In the clinical context, discussion on advantages of diagnosis disclosure can be useful for improving the care of AD patients and their families.
Resumo:
Magnetic resonance (MR) imaging is the most important imaging modality for the evaluation of traumatic or degenerative cartilaginous lesions in the knee. It is a powerful noninvasive tool for detecting such lesions and monitoring the effects of pharmacologic and surgical therapy. The specific MR imaging techniques used for these purposes can be divided into two broad categories according to their usefulness for morphologic or compositional evaluation. To assess the structure of knee cartilage, standard spin-echo (SE) and gradient-recalled echo (GRE) sequences, fast SE sequences, and three-dimensional SE and GRE sequences are available. These techniques allow the detection of morphologic defects in the articular cartilage of the knee and are commonly used in research for semiquantitative and quantitative assessments of cartilage. To evaluate the collagen network and proteoglycan content in the knee cartilage matrix, compositional assessment techniques such as T2 mapping, delayed gadolinium-enhanced MR imaging of cartilage (or dGEMRIC), T1 rho imaging, sodium imaging, and diffusion-weighted imaging are available. These techniques may be used in various combinations and at various magnetic field strengths in clinical and research settings to improve the characterization of changes in cartilage. (C)RSNA, 2011 , radiographics.rsna.org