931 resultados para colour saturation
Resumo:
There have been few studies on the mutations that cause heterozygous beta-thalassemia and how they affect the iron profile. One hundred and thirty-eight individuals were analyzed, 90 thalasemic β0 and 48 thalasemic β+, identified by classical and molecular methods. Mutations in the hemochromatosis (HFE) gene, detected using PCR-RFLP, were found in 30.4% of these beta-thalassemic patients; heterozygosity for H63D (20.3%) was the most frequent. Ferritin levels and transferrin saturation were similar in beta-thalassemics with and without mutations in the HFE gene. Ferritin concentrations were significantly higher in men and in individuals over 40 years of age. Transferrin saturation also was significantly higher in men, but only in those without HFE gene mutations. There was no significant difference in the iron profile among the β0 and β+ thalassemics, with and without HFE gene mutations. The frequency of ferritin values above 200 ng/mL in women and 300 ng/mL in men was also similar in β0 and β+ thalassemics (P > 0.72). Our conclusion is that ferritin levels are variable in the beta-thalassemia, trait regardless of the type of beta-globin mutation. Furthermore, HFE gene polymorphisms do not change the iron profile in these individuals. ©FUNPEC-RP www.funpecrp.com.br.
Resumo:
Objectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n=7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60days. All specimens were thermal cycled between 5 and 55°C with 30-s dwell times for 1000 cycles before and after disinfection. The specimens' colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T 1), after disinfection (D) and after second thermal cycling (T 2). Colour differences (ΔE) were calculated between T 1 and B (T 1B), D and B (DB), and T 2 and B (T 2B) time-points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time-points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters. © 2012 The Gerodontology Society and John Wiley & Sons A/S.
Resumo:
Colour stability of resin and silicone is an important factor for longevity of facial prostheses. The aim of this study was to evaluate the colour stability of resins and silicone for facial prostheses. Three brands of acrylic resin and one of facial silicone were evaluated considering pigment incorporation for the colourless materials. Ten samples of each material were fabricated and submitted to measurements of chromatic alteration initially and after 90 and 180 days of weathering natural through visual analysis and spectrophotometry. Data were evaluated by ANOVA and Tukey test (p < 0.05). Statistically significant colour alteration was observed among some materials regardless of the period. The materials did not present a statistical difference between 90 and 180 days except for the pigmented heat-polymerized resin. The colour difference between pigmented Silastic MDX4-4210 and colourless Silastic was statistically significant (p < 0.01) in both periods as well as between pigmented and colourless heat-polymerized resin, and between the resins Rapidaflex and Lentaflex. The visual method demonstrated colour alteration in all materials evaluated during the first 90 days of ageing. All materials exhibited colour alteration due to exposure to environment. © 2012 Informa UK, Ltd.
Resumo:
Background: Early trauma care is dependent on subjective assessments and sporadic vital sign assessments. We hypothesized that near-infrared spectroscopy-measured cerebral oxygenation (regional oxygen saturation [rSO 2]) would provide a tool to detect cardiovascular compromise during active hemorrhage. We compared rSO 2 with invasively measured mixed venous oxygen saturation (SvO2), mean arterial pressure (MAP), cardiac output, heart rate, and calculated pulse pressure. Methods: Six propofol-anesthetized instrumented swine were subjected to a fixed-rate hemorrhage until cardiovascular collapse. rSO 2 was monitored with noninvasively measured cerebral oximetry; SvO2 was measured with a fiber optic pulmonary arterial catheter. As an assessment of the time responsiveness of each variable, we recorded minutes from start of the hemorrhage for each variable achieving a 5%, 10%, 15%, and 20% change compared with baseline. Results: Mean time to cardiovascular collapse was 35 minutes ± 11 minutes (54 ± 17% total blood volume). Cerebral rSO 2 began a steady decline at an average MAP of 78 mm Hg ± 17 mm Hg, well above the expected autoregulatory threshold of cerebral blood flow. The 5%, 10%, and 15% decreases in rSO 2 during hemorrhage occurred at a similar times to SvO2, but rSO 2 lagged 6 minutes behind the equivalent percentage decreases in MAP. There was a higher correlation between rSO 2 versus MAP (R =0.72) than SvO2 versus MAP (R =0.55). Conclusions: Near-infrared spectroscopy- measured rSO 2 provided reproducible decreases during hemorrhage that were similar in time course to invasively measured cardiac output and SvO2 but delayed 5 to 9 minutes compared with MAP and pulse pressure. rSO 2 may provide an earlier warning of worsening hemorrhagic shock for prompt interventions in patients with trauma when continuous arterial BP measurements are unavailable. © 2012 Lippincott Williams & Wilkins.
Resumo:
Os testes Colour Assessment and Diagnosis (CAD) e Cambridge Colour Test (CCT) têm sido amplamente utilizados em pesquisas básicas e clínicas, devido à alta sensibilidade e especificidade de seus resultados. Estes testes utilizam diferentes paradigmas de estimulação para estimar os limiares de discriminação de cor. Pouco se sabe sobre a relação de cada paradigma na avaliação da discriminação de cor nesses testes. Sendo assim, este trabalho objetiva comparar os parâmetros de avaliação da discriminação de cor estimados pelos testes CAD e CCT em sujeitos tricromatas e com discromatopsia congênita. Foram avaliados 59 sujeitos tricromatas e 38 sujeitos discromatópsicos (16 protans, 22 deutans) com idade média de 26,32 ± 8,9 anos. Foram testados 66 sujeitos nos testes CAD e CCT, 29 sujeitos no teste CAD e 2 sujeitos no teste CCT. O fenótipo da visão de cores de todos os sujeitos foi determinado através de uma bateria de testes psicofísicos e a estimativa dos limiares de discriminação de cor foi avaliada pelos testes CAD e CCT. Os dados de limiares de discriminação de cor foram ajustados a funções de elipse. Os critérios analisados para cada sujeito foram: a área da elipse, o ângulo de rotação e tamanho dos vetores protan, deutan e tritan. Para cada um dos parâmetros foi realizada: estatística descritiva, análise da dispersão dos parâmetros entre os testes CAD e CCT e dos parâmetros em conjunto, razão entre os parâmetros, correlação dos parâmetros a três modelos matemáticos e análise de concordância. Os parâmetros de área e tamanho dos vetores deutan e tritan do subgrupo tricromata; área e tamanho do vetor tritan do subgrupo protan; e tamanho dos vetores protan e tritan do subgrupo deutan apresentaram equivalência entre os resultados de ambos os testes. Os parâmetros de área, ângulo de rotação e tamanho dos vetores protan e tritan apresentaram concordância de medidas entre os testes CAD e CCT. Fatores como as localizações distintas das coordenadas centrais dos testes CAD e CCT e a disposição espacial dos vetores no espaço de cor da CIE 1976 no teste CCT podem ter influenciado na determinação de limiares de discriminação cromática de ambos os testes. Apesar de utilizarem paradigmas distintos na configuração da estimulação, os testes CAD e CCT são equiparáveis.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The colour stability of acrylic resin denture teeth in beverages was investigated. A spectrophotometer measured the colour (CIE-L*a*b* system) of all specimens after storage in distilled water for 24 h at 37°C (T0). Specimens were then immersed in various beverages. After 15 days (T1) and 30 days (T2), for each material, the mean ∆E values were calculated and compared by two-way ANOVA and Tukey intervals (α=0.05). In the ∆T0T1 period, specimens stored in red wine were significantly discoloured, compared to distilled water (P=0.003). There was no difference between immersion solutions in ∆ET0T2 (P=0.772) and in ∆ET1T2 (P=0.058), and no difference between materials in all immersion periods.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The surface free energy of conditioned-dentin is one of the factors that interfere with monomeric infiltration of the interfibrillar spaces. Saturation of the tooth matrix with different substances may modulate this energy and, consequently, the wettability of the dentin. To evaluate the influence of different substances used to saturate conditioned-dentin on surface free energy (SFE) of this substrate. Dentin blocks (4 × 7 × 1 mm, n = 6/ group), obtained from the roots of bovine incisors, were etched using phosphoric acid for 15 seconds, rinsed and gently dried. The surfaces were treated for 60 seconds with: ultra-purified water (H20-control); ethanol (EtOH), acetone (ACT), chlorhexidine (CHX), ethylenediaminetetraacetic acid (EDTA); or sodium hypochlorite (NaOCl). The tooth surfaces were once again dried with absorbent paper and prepared for SFE evaluation using three standards: water, formamide and bromonaphthalene. Analysis of variance (ANOVA) and Dunnet's tests (a = 0.05) were applied to the data. Ethylenediaminetetraacetic acid was the only substance that caused a change to the contact angle for the standards water and formamide, while only EtOH influenced the angles formed between formamide and the dentin surface. None of the substances exerted a significant effect for bromonaphtha-lene. In comparison to the control, only EDTA and NaOCl altered both polar components of the SFE. Total SFE was increased by saturation of the collagen matrix by EDTA and reduced when NaOCl was used. Saturation of the collagen matrix by EDTA and EtOH changed the surface free energy of the dentin. In addition, the use of NaOCl negatively interfered with the properties evaluated. The increase of surface free energy and wettability of the dentin surface would allow higher penetration of the the adhesive system, which would be of importance to the clinical success of resin-dentin union.
Resumo:
Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.
Resumo:
The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target Stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees Of Visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment I Sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects` performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data-including those obtained for children-fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.
Resumo:
We assessed chromatic discrimination in multiple sclerosis (MS) patients both with (ON) and without (no ON) a history of optic neuritis using the Cambridge color test (CCT). Our goal was to determine the magnitude and chromatic axes of any color vision losses in both patient groups, and to evaluate age-related changes in chromatic discrimination in both patient groups compared to normals. Using the CCT, we measured chromatic discrimination along the protan, deutan and tritan axes in 35 patients with MS (17 ON eyes) and 74 age matched controls. Color thresholds for both patient groups were significantly higher than controls` along the protan and tritan axes (P < 0.001). In addition, the ON and no-ON groups differed significantly along all three-color axes (p < 0.001). MS patients presented a progressive color discrimination impairment with age (along the deutan and tritan axes) that was almost two times faster than controls, even in the absence of ON. These findings suggest that demyelinating diseases reduce sensitivity to color vision in both red-green and blue-yellow axes, implying impairment in both parvocellular and koniocellular visual pathways. The CCT is a useful tool to help characterize vision losses in MS and the relationship between these losses and degree of optic nerve involvement.
Resumo:
OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.
Resumo:
This paper proposes a model that adequately describes the operation of the transformer at deep saturation, suitable for power-electronics applications, and a method for determining its parameters. Simulation and experimental results are presented to confirm the validity of the model and the method.