805 resultados para clinical assessment
Resumo:
Date of Acceptance: 08/04/2015 The paper presents, in part, the results of a broader non-profit development project entitled “Advance level of knowledge for quality in clinical mentorship — professional ethics and continuously professional development”. The project was financed by the Ministry of Higher Education, Science and Sport of the Republic of Slovenia (contract no. 3211-11-000263, the number of project OP RCV_VS-11-14). The members of the development group of the project were: Brigita Skela-Savič (leader), Karmen Romih, Sanela Pivač, Katja Skinder Savić and Andreja Prebil. The research report for the entire project is available on the online bibliographic database COBIB.si, at the Faculty of Health Care Jesenice and at the Ministry of Higher Education, Science and Sport of the Republic of Slovenia.
Resumo:
Date of Acceptance: 08/04/2015 The paper presents, in part, the results of a broader non-profit development project entitled “Advance level of knowledge for quality in clinical mentorship — professional ethics and continuously professional development”. The project was financed by the Ministry of Higher Education, Science and Sport of the Republic of Slovenia (contract no. 3211-11-000263, the number of project OP RCV_VS-11-14). The members of the development group of the project were: Brigita Skela-Savič (leader), Karmen Romih, Sanela Pivač, Katja Skinder Savić and Andreja Prebil. The research report for the entire project is available on the online bibliographic database COBIB.si, at the Faculty of Health Care Jesenice and at the Ministry of Higher Education, Science and Sport of the Republic of Slovenia.
Resumo:
Date of Acceptance: 08/04/2015 The paper presents, in part, the results of a broader non-profit development project entitled “Advance level of knowledge for quality in clinical mentorship — professional ethics and continuously professional development”. The project was financed by the Ministry of Higher Education, Science and Sport of the Republic of Slovenia (contract no. 3211-11-000263, the number of project OP RCV_VS-11-14). The members of the development group of the project were: Brigita Skela-Savič (leader), Karmen Romih, Sanela Pivač, Katja Skinder Savić and Andreja Prebil. The research report for the entire project is available on the online bibliographic database COBIB.si, at the Faculty of Health Care Jesenice and at the Ministry of Higher Education, Science and Sport of the Republic of Slovenia.
Resumo:
Computed tomography (CT) is a valuable technology to the healthcare enterprise as evidenced by the more than 70 million CT exams performed every year. As a result, CT has become the largest contributor to population doses amongst all medical imaging modalities that utilize man-made ionizing radiation. Acknowledging the fact that ionizing radiation poses a health risk, there exists the need to strike a balance between diagnostic benefit and radiation dose. Thus, to ensure that CT scanners are optimally used in the clinic, an understanding and characterization of image quality and radiation dose are essential.
The state-of-the-art in both image quality characterization and radiation dose estimation in CT are dependent on phantom based measurements reflective of systems and protocols. For image quality characterization, measurements are performed on inserts imbedded in static phantoms and the results are ascribed to clinical CT images. However, the key objective for image quality assessment should be its quantification in clinical images; that is the only characterization of image quality that clinically matters as it is most directly related to the actual quality of clinical images. Moreover, for dose estimation, phantom based dose metrics, such as CT dose index (CTDI) and size specific dose estimates (SSDE), are measured by the scanner and referenced as an indicator for radiation exposure. However, CTDI and SSDE are surrogates for dose, rather than dose per-se.
Currently there are several software packages that track the CTDI and SSDE associated with individual CT examinations. This is primarily the result of two causes. The first is due to bureaucracies and governments pressuring clinics and hospitals to monitor the radiation exposure to individuals in our society. The second is due to the personal concerns of patients who are curious about the health risks associated with the ionizing radiation exposure they receive as a result of their diagnostic procedures.
An idea that resonates with clinical imaging physicists is that patients come to the clinic to acquire quality images so they can receive a proper diagnosis, not to be exposed to ionizing radiation. Thus, while it is important to monitor the dose to patients undergoing CT examinations, it is equally, if not more important to monitor the image quality of the clinical images generated by the CT scanners throughout the hospital.
The purposes of the work presented in this thesis are threefold: (1) to develop and validate a fully automated technique to measure spatial resolution in clinical CT images, (2) to develop and validate a fully automated technique to measure image contrast in clinical CT images, and (3) to develop a fully automated technique to estimate radiation dose (not surrogates for dose) from a variety of clinical CT protocols.
Resumo:
Gold nanoparticles functionalized with thiolated oligonucleotides (Au-nanoprobes) have been used in a range of applications for the detection of bioanalytes of interest, from ions to proteins and DNA targets. These detection strategies are based on the unique optical properties of gold nanoparticles, in particular, the intense color that is subject to modulation by modification of the medium dieletric. Au-nanoprobes have been applied for the detection and characterization of specific DNA sequences of interest, namely pathogens and disease biomarkers. Nevertheless, despite its relevance, only a few reports exist on the detection of RNA targets. Among these strategies, the colorimetric detection of DNA has been proven to work for several different targets in controlled samples but demonstration in real clinical bioanalysis has been elusive. Here, we used a colorimetric method based on Au-nanoprobes for the direct detection of the e14a2 BCR-ABL fusion transcript in myeloid leukemia patient samples without the need for retro-transcription. Au-nanoprobes directly assessed total RNA from 38 clinical samples, and results were validated against reverse transcription-nested polymerase chain reaction (RT-nested PCR) and reverse transcription-quantitative polymerase chain reaction (RT-qPCR). The colorimetric Au-nanoprobe assay is a simple yet reliable strategy to scrutinize myeloid leukemia patients at diagnosis and evaluate progression, with obvious advantages in terms of time and cost, particularly in low- to medium-income countries where molecular screening is not routinely feasible. Graphical abstract Gold nanoprobe for colorimetric detection of BCR-ABL1 fusion transcripts originating from the Philadelphia chromosome.
Resumo:
Objective: To assess the quality of the labels for clinical trial samples through current regulations, and to analyze its potential correlation with the specific characteristics of each sample. Method: A transversal multicenter study where the clinical trial samples from two third level hospitals were analyzed. The eleven items from Directive 2003/94/EC, as well as the name of the clinical trial and the dose on the label cover, were considered variables for labelling quality. The influence of the characteristics of each sample on labelling quality was also analyzed. Outcome: The study included 503 samples from 220 clinical trials. The mean quality of labelling, understood as the proportion of items from Appendix 13, was of 91.9%. Out of these, 6.6% did not include the name of the sample in the outer face of the label, while in 9.7% the dose was missing. The samples with clinical trial-type samples presented a higher quality (p < 0.049), blinding reduced their quality (p = 0.017), and identification by kit number or by patient increased it (p < 0.01). The promoter was the variable which introduced the highest variability into the analysis. Conclusions: The mean quality of labelling is adequate in the majority of clinical trial samples. The lack of essential information in some samples, such as the clinical trial code and the period of validity, is alarming and might be the potential source for dispensing or administration errors.
Resumo:
OBJECTIVE: To evaluate the scored Patient-generated Subjective Global Assessment (PG-SGA) tool as an outcome measure in clinical nutrition practice and determine its association with quality of life (QoL). DESIGN: A prospective 4 week study assessing the nutritional status and QoL of ambulatory patients receiving radiation therapy to the head, neck, rectal or abdominal area. SETTING: Australian radiation oncology facilities. SUBJECTS: Sixty cancer patients aged 24-85 y. INTERVENTION: Scored PG-SGA questionnaire, subjective global assessment (SGA), QoL (EORTC QLQ-C30 version 3). RESULTS: According to SGA, 65.0% (39) of subjects were well-nourished, 28.3% (17) moderately or suspected of being malnourished and 6.7% (4) severely malnourished. PG-SGA score and global QoL were correlated (r=-0.66, P<0.001) at baseline. There was a decrease in nutritional status according to PG-SGA score (P<0.001) and SGA (P<0.001); and a decrease in global QoL (P<0.001) after 4 weeks of radiotherapy. There was a linear trend for change in PG-SGA score (P<0.001) and change in global QoL (P=0.003) between those patients who improved (5%) maintained (56.7%) or deteriorated (33.3%) in nutritional status according to SGA. There was a correlation between change in PG-SGA score and change in QoL after 4 weeks of radiotherapy (r=-0.55, P<0.001). Regression analysis determined that 26% of the variation of change in QoL was explained by change in PG-SGA (P=0.001). CONCLUSION: The scored PG-SGA is a nutrition assessment tool that identifies malnutrition in ambulatory oncology patients receiving radiotherapy and can be used to predict the magnitude of change in QoL.
Resumo:
Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.
The relationship between clinical outcomes and quality of life for residents of aged care facilities
Resumo:
Objectives It is widely assumed improving care in residential facilities will improve quality of life (QoL), but little research has explored this relationship. The Clinical Care Indicators (CCI) Tool was developed to fill an existing gap in quality assessment within Australian residential aged care facilities and it was used to explore potential links between clinical outcomes and QoL. Design and Setting Clinical outcome and QoL data were collected within four residential facilities from the same aged care provider. Subjects Subjects were 82 residents of four facilities. Outcome Measures Clinical outcomes were measured using the CCI Tool and QoL data was obtained using the Australian WHOQOL‑100. Results Independent t‑test analyses were calculated to compare individual CCIs with each domain of the WHOQOL‑100, while Pearson’s product moment coefficients (r) were calculated between the total number of problem indicators and QoL scores. Significant results suggested poorer clinical outcomes adversely affected QoL. Social and spiritual QoL were particularly affected by clinical outcomes and poorer status in hydration, falls and depression were most strongly associated with lower QoL scores. Poorer clinical status as a whole was also significantly correlated with poorer QoL. Conclusions Hydration, falls and depression were most often associated with poorer resident QoL and as such appear to be key areas for clinical management in residential aged care. However, poor clinical outcomes overall also adversely affected QoL, which suggests maintaining optimum clinical status through high quality nursing care, would not only be important for resident health but also for enhancing general life quality.
Resumo:
Biotribology, the study of lubrication, wear and friction within the body, has become a topic of high importance in recent times as we continue to encounter debilitating diseases and trauma that destroy function of the joints. A highly successful surgical procedure to replace the joint with an artificial equivalent alleviates dysfunction and pain. However, the wear of the bearing surfaces in prosthetic joints is a significant clinical problem and more patients are surviving longer than the life expectancy of the joint replacement. Revision surgery is associated with increased morbidity and mortality and has a far less successful outcome than primary joint replacement. As such, it is essential to ensure that everything possible is done to limit the rate of revision surgery. Past experience indicates that the survival rate of the implant will be influenced by many parameters, of primary importance, the material properties of the implant, the composition of the synovial fluid and the method of lubrication. In prosthetic joints, effective boundary lubrication is known to take place. The interaction of the boundary lubricant and the bearing material is of utmost importance. The identity of the vital active ingredient within synovial fluid (SF) to which we owe the near frictionless performance of our articulating joints has been the quest of researchers for many years. Once identified, tribo tests can determine what materials and more importantly what surfaces this fraction of SF can function most optimally with. Surface-Active Phospholipids (SAPL) have been implicated as the body’s natural load bearing lubricant. Studies in this thesis are the first to fully characterise the adsorbed SAPL detected on the surface of retrieved prostheses and the first to verify the presence of SAPL on knee prostheses. Rinsings from the bearing surfaces of both hip and knee prostheses removed from revision operations were analysed using High Performance Liquid Chromatography (HPLC) to determine the presence and profile of SAPL. Several common prosthetic materials along with a novel biomaterial were investigated to determine their tribological interaction with various SAPLs. A pin-on-flat tribometer was used to make comparative friction measurements between the various tribo-pairs. A novel material, Pyrolytic Carbon (PyC) was screened as a potential candidate as a load bearing prosthetic material. Friction measurements were also performed on explanted prostheses. SAPL was detected on all retrieved implant bearing surfaces. As a result of the study eight different species of phosphatidylcholines were identified. The relative concentrations of each species were also determined indicating that the unsaturated species are dominant. Initial tribo tests employed a saturated phosphatidylcholine (SPC) and the subsequent tests adopted the addition of the newly identified major constituents of SAPL, unsaturated phosphatidylcholine (USPC), as the test lubricant. All tribo tests showed a dramatic reduction in friction when synthetic SAPL was used as the lubricant under boundary lubrication conditions. Some tribopairs showed more of an affinity to SAPL than others. PyC performed superior to the other prosthetic materials. Friction measurements with explanted prostheses verified the presence and performance of SAPL. SAPL, in particular phosphatidylcholine, plays an essential role in the lubrication of prosthetic joints. Of particular interest was the ability of SAPLs to reduce friction and ultimately wear of the bearing materials. The identification and knowledge of the lubricating constituents of SF is invaluable for not only the future development of artificial joints but also in developing effective cures for several disease processes where lubrication may play a role. The tribological interaction of the various tribo-pairs and SAPL is extremely favourable in the context of reducing friction at the bearing interface. PyC is highly recommended as a future candidate material for use in load bearing prosthetic joints considering its impressive tribological performance.
Resumo:
Investigated the psychometric properties of the original and alternate sets of the Trail Making Test (TMT) and the Controlled Oral Word Association Test (COWAT; A. L. Benton and D. Hamsher, 1978) in 50 orthopedic and 15 closed head injured (1 yr after trauma) patients (aged 15–59 yrs). Although the alternate forms of both measures proved to be stable and consistent with each other in both groups, only the parallel sets of TMT reliably discriminated the clinical group from controls. Practice effects in the head injured were significant only for Trail B of TMT. Factor analysis of the control group's results identified Verbal Knowledge as a major contributor to performance on COWAT, whereas TMT was more dependent on Rapid Visual Search and Visuomotor Sequencing.